CBQGQ - SODIUM PERBORATE

Product Identification

Product ID:SODIUM PERBORATE
MSDS Date:01/01/1996
FSC:6810
NIIN:00-241-1105
MSDS Number: CBQGQ

Responsible Party
BIORAMA INC (1685 ELMWOOD AVE; BUFFALO, NY)
242 SUNDRIDGE DR (MAILING ADDRESS)
AMHERST, NY 14228
US

Emergency Phone: 800-424-9300 CHEMTREC

Info Phone: 716-875-0009

Cage: 01VT8

Contractor
BIORAMA INC (1685 ELMWOOD AVE; BUFFALO, NY)
1518 AMHERST, NY 14228 US

Telephone: 716-691-5080

Cage: 01VT8

Ingredients

SODIUM PERBORATE (SODIUM PERBORATE, TETRAHYDRATE)

CAS: 10486-00-7

RTECS: SC7350000

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 1200 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTACT WITH SKIN AND EYE MAY
CAUSE IRRITATION. INHALATION MAY CAUSE RESPIRATORY IRRITATION. VERY
DANGEROUS WHEN INGESTED. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:SKIN-IRRITATION. EYES-IRRITATION.
INHALED-RESPIRATORY IRRITATION. INGESTED-NONE SPECIFIED.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-FLUSH WITH WATER FOR
15 MINUTES. SKIN-REMOVE CONTAMINATED CLOTHES. WASH WITH MILD SOAP &
WATER. INHALED-REMOVE TO FRESH AIR. ADMINISTER OXYGEN OR ARTIFICIAL
RE SPIRATION AS NEEDED. INGESTED-IF CONSCIOUS, GIVE WATER OR MILK
AND INDUCE VOMITING.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:NON-FLAMMABLE. DLA-HMIS: USE MEDIA APPROPRIATE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:NONE. HMIS: WEAR SELF-CONTAINED BREATHING
APPARATUS AND FULL FIRE FIGHTER'S PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:USE APPROPRIATE TOOLS TO PUT IN APPROPRIATE
WASTE DISPOSAL CONTAINER. AVOID CONTACT WITH COMBUSTIBLE MATERIALS.
KEEP DAMP USING WATER SPRAY. PREVENT ENTRY INTO SEWERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, IGNITION SOURCES,
COMBUSTIBLE MATERIALS. STORE IN SEPARATE SAFETY STORAGE.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR WITH
DUST CARTRIDGE OR AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED.
USE IAW 29 CFR 19 10.134.
Ventilation:USE LOCAL EXHAUST TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:CHEMICAL RESISTANT.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:LAB COAT. DLA-HMIS: EYE WASH STATION &
SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
MSDS PRESENTED BY CAGE 01VT8 FOR CONTRACT SP0450-96-M-L901.

Chemical Properties

HCC:D1
Appearance and Odor:WHITE, CRYSTALLINE POWDER; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.