Product Identification
Product ID:B6104G,GRAM IODINE
MSDS Date:08/30/1996
FSC:6550
NIIN:00D005578
MSDS Number: CBSVL
Responsible Party
BURLINGTON, NC 27215-3387
US
Emergency Phone: 910-584-0381 800-424-9300(CHEMTREC)
Info Phone: 910-584-0381
Cage: 59896
Contractor
Telephone: 800-227-1150/910-584-0381
Cage: 59896
Ingredients
POTASSIUM IODIDE
CAS: 7681-11-0
RTECS: TT2975000
Fraction By Weight: 0.67%
IODINE
CAS: 7553-56-2
RTECS: NN1575000
Fraction By Weight: 0.33%
OSHA PEL C 0.1 PPM
ACGIH TLV: C 0.1 PPM; 9596
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 1862MG/KG(INGRED #1)
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:MAY CAUSE IRRITATION.SKIN:MAY
CAUSE IRRITATION.INGEST:MAY CAUSE GI TRACT IRRITATION.INHAL:MAY
CAUSE RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN AND
RESPIRATORY AILMENTS MAY BE AT INCREASED RISK FROM EXPOSURE.
First Aid
First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH WATER.EYES:FLUSH
WITH WATER FOR 15 MINUTES.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN OR
ARTIFICIAL RESPIRATION IF NEEDED.INGEST:DO NOT INDUCE VOMITING.GET
PROMP T QUALIFIED MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:EXCESSIVE TEMPERATURES MAY EMIT TOXIC AND
CORROSIVE FUMES OF IODINE.
Accidental Release
Spill Release Procedures:ELIMINATE SOURCES OF IGNITION.USE PROPER
RESPIRATORY AND PROTECTIVE EQUIPMENT.VENTILATE AREA.SOAK UP WITH A
NON-COMBUSTIBLE INERT ABSORBANT(CLAY,SAND);PLACE IN PROPER
CONTAINER FOR DISPOSAL.
Neutralizing Agent:NOT REPORTED.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
PLACE.KEEP CONTAINER CLOSED WHEN NOT IN USE.KEEP AWAY FROM HEAT AND
INCOMPATIBLE MATERIALS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
VAPORS.
Ventilation:LOCAL VENTILATION AT THE WORKSITE;MECHANICAL(GENERAL)
VENTILATION TO MAINTAIN TLV/PEL.
Protective Gloves:RUBBER,NEOPRENE,PVC.
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:LAB COAT.PROVIDE A LOCAL EYE WASH STATION
AND SAFETY SHOWER.
Work Hygienic Practices:EXECISE GOOD LABORATORY PRACTICES.WASH HANDS
AFTER USE AND BEFORE EATING.
Supplemental Safety and Health
NONE
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:17.535
Spec Gravity:1
Solubility in Water:COMPLETE
Appearance and Odor:DEEP AMBER LIQUID WITH SLIGHT CHARACTERISTIC ODOR
OF IODINE.
Percent Volatiles by Volume:99
Stability
Stability Indicator/Materials to Avoid:YES
CONTACT WITH AMMONIA FUMES MAY CAUSE FORMATION OF EXPLOSIVE
NITROIODIDE.
Stability Condition to Avoid:HIGH HEAT.
Hazardous Decomposition Products:FREE IODINE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.