CBSYT - 2001 RUBBER SOLVENT
- MSDS: CBSYT
- Manufacturer: UNION OIL CO OF CA UNION 76 DIV WESTERN RGION
- Product Name: 2001 RUBBER SOLVENT
- National Stock Number: 6810-00-227-1302
Product Identification
Product ID:2001 RUBBER SOLVENT
MSDS Date:12/08/1995
FSC:6810
NIIN:00-227-1302
MSDS Number: CBSYT
Responsible Party
LOS ANGELES, CA 90017-1443
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 800-356-3212
Cage: 79003
Contractor
Telephone: 316-838-4663
Cage: 79003
Ingredients
RUBBER SOLVENT
CAS: 64742-89-8
OTHER HEPTANE ISOMERS
OTHER HEXANE ISOMERS (CAS# VARIES)
HEXANE (N-HEXANE) (CERCLA)
CAS: 110-54-3
RTECS: MN9275000
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
N-HEPTANE
CAS: 142-82-5
RTECS: MI7700000
OSHA PEL 500 PPM
ACGIH TLV: 400 PPM/500STEL;9596
PENTANE
CAS: 109-66-0
RTECS: RZ9450000
OSHA PEL 1000 PPM
ACGIH TLV: 600 PPM/750STEL;9596
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM; Z-2
ACGIH TLV: S, 50 PPM; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CYCLOHEXANE (SARA 313) (CERCLA)
CAS: 110-82-7
RTECS: GU6300000
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM, 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
OTHER C5-C10 PARAFFINS AND CYCLOPARAFFINS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CAUSES EYE/SKIN IRRIT.OVEREXPO MAY
CAUSE DMG TO PERIPHERAL NERVOUS SYS.ASPIRATION HAZ IF INGEST.CAN
ENTER LUNGS,CAUSE DMG.EYE:IRRIT,MAY
STING,WATER,REDNESS,SWELL.SKIN:IRRIT,REDNESS,BURN,DRY,CRACK,DMG
SKIN.LOW DEGREE OF HAZ BY SKIN ABSORPTION.INHAL/INGEST:LOW-MODERATE
DEGREE OF TOXICITY.ASPIRATION HAZ-ENTER LUNGS(SUPPL)
Explanation of Carcinogenicity:PER MSDS:INADEQUA EVIDENCE AVAI TO
EVALUATE CANCER HAZ OF THIS MATL.
Effects of Overexposure:IRRITATION OF NOSE/THROAT, IRRIT OF DIGESTIVE
TRACT, NAUSEA, VOMITING, DIARRHEA, SIGNS OF NERVOUS SYTEM
DEPRESSION (HEADACHE, DROWSINESS, DIZZINESS, LOSS OF COORDINATION,
FATIGUE), GIDDINESS, LOSS OF APPETITE.REPORTS HAVE ASSOC REP/PROL
OCCUPAT OVEREXPO TO SOLVNTS W/PERM BRAIN/NERV SYS DMG(SOLVNT OR
PAINTERS SYNDROME).
Medical Cond Aggravated by Exposure:MAY INCLUDE
SKIN/RESP(ASTHMA-LIKE)/KIDNEY/LIVER/MALE REPRODUCTIVE/PERIPHERAL
NERVE DISORDERS.PERSONS W/PRE-EXISTING HEART DISORDERS MAY BE MORE
SUSCEPTIBLE.TARORG:CNS,LIVER/KIDNEY.
First Aid
First Aid:EYE:MOVE INTO FRESH AIR.IRRIT/RED OCCUR FLUSH W/CLEAN
WATER,HOLD EYELIDS OPN,FOR @LEAST 15MINS.SKIN:REMOVE CONTAM
CLOTH/SHOE.FLUSH W/LG AMTS OF WATER.SKIN DMG APPLY CLEAN
DRESSING;NOT DMG CLEAN/WASH W ELL W/MILD SOAP/WATER.INHAL:MOVE INTO
FRESH AIR.NOT BREATH IMMED BEGIN ART RESP;BREATH DIFFI QUAL PERSON
ADMIN OXY.INGEST:ASPIRATION HAZ-DON'T INDUCE VOMIT/GIVE ANYTHING BY
MOUTH.DROWSY/UNCONSC(SUPPL)
Fire Fighting
Flash Point Method:TCC
Flash Point:<0F,<-18C
Autoignition Temp:Autoignition Temp Text:520F
Lower Limits:1.0
Upper Limits:8.0
Extinguishing Media:FLAMM LIQ.DRY CHEMI,CO2,HALON,FOAM.H2OSPRAY TO
COOL/PROT EXPO MATL/STRUCTURES.H2O MAY BE INEFFECT.USE CAUT
W/HALON,CO2.
Fire Fighting Procedures:WEAR BUNKER GEAR/SCBA FOR FIRES BEYOND
INCIPIENT STAGE.ADDN PPE AS CONDITIONS WARRANT.ISOLATE AREA,KEEP
UNAUTH PEOPLE OUT.MOVE UNDMG CNTNR AWAY.COOL ITEMS W/H2O
Unusual Fire/Explosion Hazard:VAP TRAVEL CONSIDERABLE DISTANCE TO IGN
SOURCE-CAN IGN,FLASHBACK,EXPLO.CREATE VAP/AIR EXPLO HAZ.VAP HEAVIER
THAN AIR,ACCUMULATE IN LOW AREA.CNTNR NOT COOL EXPLO
Accidental Release
Spill Release Procedures:FLAMM.KEEP SLL IGN SOURCE/HOT METAL SURF
AWAY.USE EXPLO-PROOF EPMT.STAY UPWIND.ISOLATE AREA.STOP LEAK/SPILL
W/O RISK.WEAR PPE.PREVENT FROM ENTER
SEWER/STORE/DRAIN/ETC.DIKE.ABSORB W/APPROP ABSORBANT MA TL.NOTIFY
AUTHORITIES.ENTER WATERS CALL(NEUTRAL)
Neutralizing Agent:SPILL:NAT RESP CNTR 800-424-8802.
Handling
Handling and Storage Precautions:OPN CNTNR SLOW.BOND/GROUND EPMT.DON'T
ENTER CONFINED SPACE W/O PROPER
PROCEDURE(ASTMD4276,29CFR1910.146).EMPTY CNTNR RETAIN
RESIDUE-HAZ.REF:ANSI Z49.1
Other Precautions:USE VENTI ADEQUA-KEEPS EXPO BEL RECOMMENDED EXPO
LIMITS.AVOID BREATH VAP/MIST.DON'T GET IN EYE/SKIN/CLOTH.DON'T
TASTE/SWALLOW.FLAMM LIQ/VAP.KEEP AWAY FROM HEAT/SPARK/FLAME/OTHER
IGN SOURCES.INTENTIONA L MISUSE BY DELIBERATE CONC/INHAL (SUPP)
Exposure Controls
Respiratory Protection:CURRENT VENTI PRAC NOT ADEQUATE TO MAINTAIN
AIRBORNE CONC BEL ESTABLISHED EXPO LIMITS ADDN VENT/EXHAU SYS
REQUIRED.WHERE EXPLO MIX PRESENT USE ELECTR SYS SAFE FOR SUCH
AREAS.AIRBORNE CONC EXCEEDED USE SUPP-AIR RESP.NO CHEM CARTRIDGE
RESP.
Ventilation:SEE RESPIRATORY PROTECTION SECTION.
Protective Gloves:IMPERMEABLE TO SPEC MATL HNDLG.
Eye Protection:RECOMMENDED.
Other Protective Equipment:EYEWASH,QUICK-DRENCH SHOWER FACILITIES AVAI
IN WORKAREA.IMPERVIOUS CLOTHING BE WORN.
Work Hygienic Practices:WASH THOROUGHLY AFT HNDLG.DON'T WEAR CONTAMIN
CLOTH/SHOE.USE GOOD PERSONAL HYGIENE PRAC.
Supplemental Safety and Health
HEALTH HAZ:DURING INGEST/VOMIT-CAUSE LUNG INFLAMM/DMG.HI CONC EXPO MAY
CAUSE IRREG HEARTBEATS(ARRHYTHMIAS). 1STAID:PLACE ON LEFT SIDE,HEAD
DOWN.IN ALL CASES GET MED ATTN.DR:HI CONC EXPO ASSOC W/CARDIA C
ARRHYTHMIAS.EPINEPHRINE/SYMPATHOMIMATIC DRUGS MAY INITIATE CARDIAC
ARRHYTHMIAS. OTHER PRECAU:MATL MAY BE HARMFUL/FATAL
Chemical Properties
HCC:F2
Boiling Pt:B.P. Text:114F,46C
Melt/Freeze Pt:M.P/F.P Text:NO DATA
Decomp Temp:Decomp Text:NP
Vapor Pres:180
Vapor Density:3.2
Spec Gravity:0.701
VOC Pounds/Gallon:701
pH:NA
Viscosity:0.564 CST@20C
Evaporation Rate & Reference:6.1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:LIQUID, CLEAR COLORESS, LIGHT HYDROCARBON ODOR.
Percent Volatiles by Volume:100
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS & REDUCING AGENTS.
Stability Condition to Avoid:FLAMM LIQ-MAY BE IGNITED BY
HEAT,SPARKS/FLAMES/OTHER SOURCES OF IGN(STATIC ELECTRICITY,PILOT
LIGHTS,MECHAN/ELEC EQPMT).
Hazardous Decomposition Products:COMBUSTION CAN YIELD CARBON DIOXIDE &
CARBON MONOXIDE.
Disposal
Waste Disposal Methods:COMPLETELY DRAIN/PROPERLY BUNGE/PROMTLY SHIPP
EMPTY DR TO SUPPLIER/DR RECONDITIONER.DISPO ALL CNTNR IN ENVIRON
SAFE MANNER,IAW GOVT REGS.RCRA HAZ WASTE-D001,D018 UNUSED
PROD.CONSULT STATE/LOC REGS REG ARDING PROPER DISPO OF MATL.HAS
SARA/CERCLA CHEMS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.