CBSZT - X-6989

Product Identification

Product ID:X-6989
MSDS Date:01/05/1996
FSC:8010
NIIN:00-515-2208
MSDS Number: CBSZT

Responsible Party
SENTRY PAINT AND CHEMICAL CO
MILL AND LAWRENCE ST
DARBY, PA 19023
US

Emergency Phone: 800-424-9300 CHEMTREC

Info Phone: 610-522-1900

Preparer: JOHN BIELSKI

Cage: 34346

Contractor
SENTRY PAINT AND CHEMICAL CO
DARBY, PA 19023 US

Cage: 34346

Ingredients

VM & P NAPHTHA (LIGHT ALIPHATIC PETROLEUM SOLVENT NAPHTHA)

CAS: 64742-89-8

Fraction By Weight: 15-30%


ISOBUTYL ALCOHOL (CERCLA)

CAS: 78-83-1

RTECS: NP9625000

Fraction By Weight: 0.5-5.0%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA 313) (CERCLA)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 1.3%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL;9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 5.1%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOPROPYL ALCOHOL (SARA 313)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 5-15%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500STEL;9596


N-BUTYL ALCOHOL (SARA 313) (CERCLA)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 2.8%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


PM ACETATE OR PROPYLENE GLYCOL MONOMETHYL ETHER ACETATE

CAS: 108-65-6

RTECS: AI8295000

Fraction By Weight: 0.5-5.0%

OSHA PEL NOT ESTABLISHED.

ACGIH TLV: NOT ESTABLISHED.


CHROMIUM (SARA 313) (CERCLA)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 7.6%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ZINC (SARA 313) (CERCLA)

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 8.8%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRODUCT CONTAINS ZINC CHROMATE WHICH
HAS BEEN LISTED BY NTP,IARC AS A CARCINOGEN.HARMFUL IF INHALED OR
SWALLOWED.LONG TERM EXPOSURE MAY CAUSE CANCER.REPEATED/PROLONGED
EXPOSURE MAY CAUSE DELAYED EFFEC TS INVOLVING IRRITATION OF NOSE &
THROAT,IRRITATION OR CORROSION OF GI TRACT,CIRCULATORY
COLLAPSE,NEPHRITIS.
Explanation of Carcinogenicity:PER MFR ZINC CHROMATE LISTED; DLA-HMIS
FOUND HEXAVALENT CHROMIUM COMPOUNDS LISTED BUT NOT ZINC CHROMATE
INDIVIDUALLY.
Effects of Overexposure:EYES-IRRITATION, REDNESS, TEARING, BLURRED
VISION. SKIN-DRYNESS, IRRITATION, DERMATITIS. INHALED-NASAL &
RESPIRATORY IRRITATION, DIZZINESS, WEAKNESS, NAUSEA, HEADACHE.
INGESTED-NAUSEA, VOMITING, DIARR HEA. ASPIRATION MAY CAUSE CHEMICAL
PNEUMONITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
NOTE: REPORTS HAVE ASSOCIATED REPEATED & PROLONGED EXPOSURE TO
BRAIN & NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE MAY BE HARMFUL OR
FATAL.

First Aid

First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-FLUSH WITH WATER FOR
15 MINUTES. SKIN-REMOVE CONTAMINATED CLOTHES. WASH WITH MILD SOAP &
WATER. INHALED-REMOVE TO FRESH AIR. ADMINISTER OXYGEN OR ARTIFICIAL
RE SPIRATION AS NEEDED. INGESTED-DO NOT INDUCE VOMITING! KEEP
PRESON WARM & QUIET.

Fire Fighting

Flash Point Method:CC
Flash Point:40.0F,4.4C
Lower Limits:0.9
Upper Limits:12.7
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY BUILD UP PRESSURE
FROM HEAT. VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL ALONG GROUND TO
DISTANT IGNITION SOURCE.

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIMINATE ALL SOURCES OF
IGNITION. DIKE & CONTAIN WITH INERT MATERIALS. TARNSFER LIQUIDS TO
METAL CONTAINERS. USE ONLY ON-SPARKING TOOLS. PREVENT CONTAMINATION
OF SEWERS, STREAMS , GROUNDWATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DLA-HMIS: STORE IN A COOL, DRY,
WELL-VENTILATED PLACE AWAY FROM SOURCES OF IGNITION AND
INCOMPATIBLE MATERIALS.
Other Precautions:DLA-HMIS: PROPERLY BOND & GROUND CONTAINERS DURING
TRANSFER OPERATIONS.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR WITH
ORGANIC VAPOR CARTRIDGE OR AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS
REQUIRED. USE IAW 29 CFR 1910.134.
Ventilation:USE LOCAL EXHAUST TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:NITRILE, BUTYL PVA.
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS.
Other Protective Equipment:EYE WASH STATION & SAFETY SHOWER. TO PREVENT
REPEATED OR PROLONGED SKIN CONTACT WEAR IMPERVIOUS CLOTHING &
BOOTS.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:180F,82C
Vapor Pres:<3.8
Vapor Density:>1
Spec Gravity:1.21
Viscosity:20-25 SEC #2
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW LIQUID; HYDROCARBON ODOR.
Percent Volatiles by Volume:66.2

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING
AGENTS,CAUSTICS,AMINES,ALKAMINES,ALDEHYDES,AMMONIA,CHLORINATED
COMPOUNDS.DO NOT HANDLE IN AL EQUIPMENT.
Stability Condition to Avoid:EXCESS HEAT, SPARKS, OPEN FLAME. AVOID
CONTACT WITH STRONG OXIDIZING AGENTS, CAUSTICS, AMINE, ALKAMINES,
ALDEHYDES......
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE,
PHENOL.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:EPA HAZWASTE CODE-F003. DISPOSE OF IN ACCORDANCE
WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL REGULATIONS. INCINERATE
ONLY IN AN EPA PERMITTED FACILITY. DO NOT INCINERATE CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.