CBWNQ - 1210

Product Identification

Product ID:1210
MSDS Date:07/20/1991
FSC:6850
NIIN:00N067127
MSDS Number: CBWNQ

Responsible Party
J AND M LABORATORIES INC
1717 ROWAN ST
LOUISVILLE, KY 40203
US

Emergency Phone: 800-473-6173

Info Phone: 502-585-3176

Cage: 01VT9

Contractor
J AND M LABORATORIES, INC.
LOUISEVILLE, KY 40203 US

Telephone: 800-473-6173/502-585-3176

Cage: 01VT9

Ingredients

METAPHOSPHORIC ACID, HEXASODIUM SALT; (SODIUM

CAS: 10124-56-8

RTECS: OY3675000

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SODIUM ACRYLATE POLYMER

OSHA PEL N/K

ACGIH TLV: N/K


POLYMALEIC ACID

CAS: 26099-09-2

OSHA PEL N/K

ACGIH TLV: N/K


HYDROXYETHYLIDENEDIPHOSPHONIC ACID

OSHA PEL N/K

ACGIH TLV: N/K


SEMICONSCIOUS, COMATOSE OR CONVULSING, DO NOT GIVE

RTECS: 9999999ZZ


RECOVER AS MUCH OF PURE PROD AS POSS INTO

RTECS: 9999999ZZ


MAY BE USED TO RECOVER ANY MATL THAT CAN NOT READILY

RTECS: 9999999ZZ


RESPONSIBLE FOR OPERATION OF YOUR FACILITY'S INDUS

RTECS: 9999999ZZ


SPILLS OR LEAKS OF THIS PRODUCT TO THE INDUSTRIAL

RTECS: 9999999ZZ


WASTE. HOWEVER, SPILL OR LEAK RESIDUALS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS MATERIAL IS NOT CONSIDERED TO BE
A CARCINOGEN BY NTP, IARC OR OSHA.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:WASH EXPOS AREA W/PLENTY OF SOAP & WATER. REPEAT
WASHING. RINSE EXPOS AREA FOR AT LEAST 15 MIN. CONSULT HLTH CARE
PROFESSIONAL. IF CLTHG COMES IN CNTCT W/PROD, CLTHG SHOULD BE
REMOVED IMMED & LAU NDERED BEFORE REUSE. EYES: FLUSH IMMED
W/COPIOUS AMTS OF TAP WATER OR NORM SALINE FOR MINIMUM OF 15 MIN.
TAKE EXPOS INDIVIDUAL TO HLTH CARE PROFESSIONAL. INHAL: IF PERSON
EXPERIENCES NAUS, (SUPDAT)

Fire Fighting

Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:WATER FOG, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:INITIALLY MINIMIZE AREA EFFECTED BY
SPILL/LEAK. BLOCK ANY POTNTL ROUTES TO WATER SYS. ASSESS IMPACT ON
CONTAMD ENVIRONS & MINIMIZE ANY ADVERSE EFTS. CNTCT J&M
REPRESENTATIVE IMMED. DETERM IF FED, STAT E &/OR LOC RELS
NOTIFICATION IS REQD. (ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID AREAS OF EXTREME HEAT OR COLD.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NONE REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:GENERAL (MECHANICAL) ROOM VENTILATION IS EXPECTED TO BE
SATISFACTORY.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EMERGENGY EYE WASH & DELUGE
SHOWER . WEAR IMPERVIOUS APRON.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH: 11.5-12.5. FIRST AID PROC: HDCH OR DIZZ, IMMED MOVE TO FRESH AIR.
IF INDIVIDUAL HAS DFCLTY BRTHG OR IS CYANOTIC ADMIN OXYGEN IF
AVAIL. CALL MD. INGEST: DO NOT INDUCE VOMIT. RINSE MOUTH W/COPIOUS
A MTS OF WATER/MILK FIRST. THEN SLOWLY DILUTE STOM CONTENTS W/6 TO
8 OZ OF WATER. IN CASES WHERE INDIVIDUAL IS (ING 5)

Chemical Properties

Spec Gravity:9.3
pH:SUPDAT
Solubility in Water:MISCIBLE
Appearance and Odor:CLEAR, EMBER LIQUID; MODERATE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:CONTAMINATION OF ANY KIND.
Hazardous Decomposition Products:BURNING MAY LIBERATE CARBON MONOXIDE,
CARBON DIOXIDE, HYDROGEN GAS, NITROGEN OXIDES.

Disposal

Waste Disposal Methods:FOLLOW ALL FED, STATE & LOC REGS GOVERNING DISP
OF WASTE MATLS. DETERM IF WASTE CONTAINING THIS PROD CAN BE HANDLED
BY AVAIL INDUS EFFLUENT SYS OR OTHER ON-SITE WASTE MANAGEMENT. PROD
IS NOT SPECIFICA LLY LISTED IN 40 CFR 261 AS RCRA HAZ (ING 10)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.