CCBYP - 76 GUARDOL OIL 30
- MSDS: CCBYP
- Manufacturer: UNION OIL CO OF CALIFORNIA UNOCAL CHEMICALS DIV
- Product Name: 76 GUARDOL OIL 30
- National Stock Number: 9150-00-186-6696
Product Identification
Product ID:76 GUARDOL OIL 30
MSDS Date:10/04/1995
FSC:9150
NIIN:00-186-6696
MSDS Number: CCBYP
Responsible Party
LOS ANGELES, CA 90060
US
Emergency Phone: 800-424-9300(CHEMTREC)/503-641-3222
Info Phone: 213-977-7589
Cage: 23034
Contractor
Telephone: 213-977-7589
Cage: 23034
Ingredients
MINERAL OIL,HYDROTREATED (SEVERE), PETROLEUM DISTILLATE,
CAS: 64742-54-7
RTECS: PY8035501
Fraction By Weight: 0-95%
MINERAL OIL, PETROLEUM DISTILLATE, SOLVENT DDEWAXED
CAS: 64742-65-0
RTECS: PY8038501
Fraction By Weight: 0-95%
ADDITIVES
Fraction By Weight: 11.5-14%
SOLVENT DEWAXED RESIDUAL OIL (PETROLEUM)
CAS: 64742-62-7
Fraction By Weight: 0-11%
ZINC COMPOUND
Fraction By Weight: 1-2%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and
Chronic:EYE:IRRIT,STINGING,WATERING,REDNESS,SWELLING.SKIN:MILD
IRRIT,REDNESS,BURNING,DRYING,CRACKING,NO HARMFUL EFFECTS FROM
ABSORPTION.INHAL:NO INFO AVAIL.STUDIES BY OTHER EXPO RTS SUGGEST
LOW DEGREE OF TOXI CITY.INGEST:NO HARMFUL EFFECTS REPORTED.
Explanation of Carcinogenicity:PER MSDS:AMTL HAS NOT BEEN ID AS
CARCINOGEN BY NTP/IARC/OSHA.USED MOTOR OIL ID AS POSSIBLE SKIN
CANCER BY IARC.
Effects of Overexposure:IRRIT OF NOSE/THROAT & DIGESTIVE TRACT.
Medical Cond Aggravated by Exposure:CONDITIONS AGGRAVATED BY EXPO MAY
INCLUDE SKIN DISORDERS. TARGET ORGANS:INADEQUATE DATA AVAILABLE.
First Aid
First Aid:EYE:MOVE TO FRESH AIR.IRRIT/RED OCCURS FLUSH W/WATER.GET MED
ATTN.DIRECT CONTACT FLUSH W/WATER FOR @LEAST 15MINS LIFT
EYELIDS.GET MED ATTN.SKIN:WIPE OFF EXCESS.REMOVE COTNAMIN
CLOTH/SHOES/WASH WELL W/ MILD SOAP/WATER/WATERLESS SKIN
CLEANSER.IRRIT/RED OCCURS GET MED ATTN.INHAL:MOVE TO FRESH
AIR.SUMPT PERSIST GET MED ATTN.NOT BREATH IMMED BEGIN ART
RESP;BREATH DIFFI OXY GIVEN BY QUAL PEROSN.(SUPPLE)
Fire Fighting
Flash Point Method:COC
Flash Point:428F,220C
Autoignition Temp:Autoignition Temp Text:NO DAT
Lower Limits:NO DATA
Upper Limits:NO DATA
Extinguishing Media:DRY CHEMI,CO2,HALON,FOAM,WATERSPRAY.WATER/FOAM
CAUSE FROTHING OF MATLS HEATED >212F.HALON DECOMPO INTO TOXIC
MATLS.(SUP)
Fire Fighting Procedures:WEAR BUNKER GEAR,SCBA FIRE BEYOND INCIPIENT
STAGE,OTHER APPROP PPE AS CONDITIONS WARRANT.ISOLATE
AREA.WATERSPRAY MIN/DISPERSE VAP.COOL W/WATER.AVOID SPREAD LIQ.
Unusual Fire/Explosion Hazard:MATL MAY BURN BUT WILL NOT IGN
READILY.VAP HEAVIER THAN AIR & ACCUMULATE IN LOW AREAS.CNTNR NOT
PROPERLY COOLED CAN EXPLO IN HEAT OF FIRE.
Accidental Release
Spill Release Procedures:MAY IGNITE-REMOVE ALL IGN SOURCES.USE
EXPLO-PROOF EQPMT.STAY UPWIND/AWAY.ISOLATE/STOP LEAK W/O RISK.WEAR
PPE.PREVENT FROM ENTER SEWERS/STORM DRAINS/OTHER DRAINAGE SYS/NAT
WATERS.NOTIFY AUHTORITIES/NAT RESP CNTR 800-424-8802.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DON'T ENTER CONF SPACES(TK,PITS)W/O
PROPER ENTERY PROCEDURES(ASTMD4276/29CFR1910.146).FOLLOW OSHA ANSI
Z49.1/GOVT/INDUST REFS ON CLEAN/REPAIR/ETC.
Other Precautions:EMPTY CNTRN RETAIN RESIDUE(LIQ/VAP)-DANGEROUS.DON'T
PRESS/CUT/WELD/BRAZE/SOLDER/DRILL/GRIND/EXPO CNTNR TO
HEAT/FLAME/SPARK/OTHER IGN SOURCE.MAY EXPLO/CAUSE INJURY/DEATH.KEEP
TIGHTLY CLSD.USE/STORE IN COOL DRY WELL VENTI AREA/APPROVED CNTNR.
Exposure Controls
Respiratory Protection:CURRENT VENTI PRAC AREN'T ADEQUATE TO MAINTAIN
AIRBORNE CONC BELOW ESTABLISHED EXPO LIMITS ADDN
VENTILATION/EXHAUST SYS MAY BE REQUIRED.USE RESP WHEN CONC EXCEED
ESTABLISHED EXPO LIMITS.DEPEND ON CONC USE APPROP CATRID NOISH
APPROVE/AIRSUPP
Ventilation:SEE RESPIRATORY PROTECTION.RER.
Protective Gloves:IMPERMEABLE SPEC TO MATL HNDL GLOVES.
Eye Protection:APPROVED EYE PROTECTION
Other Protective Equipment:SOURCE OF CLEAN WATER BE AVAILABLE IN
WORKAREA FOR FLUSING EYE/SKIN.IMPERVIOUS CLOTH SHOULD BE WORN AS
NEEDED.
Work Hygienic Practices:WASH THROUGHLY AFT HNDLG.DON'T WEAR CONTAMIN
CLOTH/SHOES.USE GOOD PERSONAL HYGIENE PRACTICE.
Supplemental Safety and Health
EXT MATL:CO DISPLACES OXY.USE CAUT WHEN USE HALON/CO2 IN CONF AREA.
1STAID:GET MED ATTN.INGEST:NO 1STAID NORMALLY REQUIRED.IF
INGEST/SYPMT OCCURS GET MED ATTN.DR:ASPIRATION PRODUCES SER
ASPIRATION PNE UMONIA.
Chemical Properties
HCC:V6
Boiling Pt:B.P. Text:>556F,>291C
Melt/Freeze Pt:M.P/F.P Text:NO DATA
Decomp Temp:Decomp Text:NP
Vapor Pres:NO DATA
Vapor Density:>1
Spec Gravity:0.89-0.90
pH:NO DAT
Viscosity:100-11CST@40C
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:CLEAR BROWN, LIQUID, CHARACTERISTIC PETROLEUM ODOR.
Percent Volatiles by Volume:NEGLIG
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
AVOID COTNACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXTENDED EXPO TO HIGH TEMPERATURES CAN
CAUSE DECOMPOSITION.
Hazardous Decomposition Products:COMBUST:MAJOR AMTS OF OXIDES OF CARBON
& MINOR AMTS OF OXIDES OF NITROGEN, PHOSPHORUS, SULFUR, ZINC.
Disposal
Waste Disposal Methods:EMPTY DR COMPLETELY DRAIN/PROPERLY BUNG/PROMPTLY
SHIP TO SUPPLIER/DR RECONDITIONER.ALL CNTRN SHOULD BE DISPO IN
ENVIRO SAFE MANNER/IAW GOVT REGS.AS IS NOT HAZ WASTE.CONSULT
STATE/LOC REGS REGARDING PR OPER DISPO OF MATL.SARA 313 CHEM:ZN
CMPD.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.