CCCGJ - THORIUM-232

Product Identification

Product ID:THORIUM-232
MSDS Date:01/01/1987
FSC:6665
NIIN:01-247-7284
MSDS Number: CCCGJ

Responsible Party
OAK RIDGE NATIONAL LABORATORY
OAK RIDGE, TN
US

Info Phone: 215-343-4670

Cage: NO290

Contractor
OAK RIDGE NATIONAL LABORATORY
H OAK RIDGE, TN 18976-2424 US

Telephone: 215-343-4670

Cage: NO290

Ingredients

THORIUM 232 (0.03 MICOCURIES OR 30 NANOCURIES)

Hazards

Routes of Entry: Inhalation:UNKNOWN Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN-RADIOACTIVE EXPOSURE OF
BARE SKIN CAN RESULT FOR PROLONGED EXPOSURE. INGESTION-RADIOACTIVE
EXPOSURE OF INTERNAL ORGANS CAN RESULT FROM INGESTION OF METAL.
CHRONIC EFFECTS/CARCINOGENICITY: PROLONGED EXPOSURE CAN BE
CARCINOGENIC.
Explanation of Carcinogenicity:EXPOSURE TO RADIOACTIVITY OVER EXTENDED
PERIODS OF TIME MAY CAUSE VARIOUS FORMS OF CANCER.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: GET VICTIM TO
PHYSICIAN OR EMERGENCY ROOM IMMEDIATELY. BE SURE AND TELL MEDICAL
PERSONNEL THAT POSSIBLE RADIOACTIVITY/RADIATION IS INVOLVED.

Fire Fighting

Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: MEDIA
APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:AS A MINIMUM; RESPIRATORY PROTECTION FOR FIRE
FIGHTING OPERATIONS INVOLVING LARGE AMOUNTS OF SOURCE MATERIAL AS
THE SMOKE MAY BE RADIOACTIVE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:MOVE UNDAMAGED PACKAGES FROM THE SPILL AREA.
PICK-UP MATERIAL. DECONTAMINATE THE SPILL AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP IN STORAGE CONTAINER WHEN NOT IN
USE. DO NOT TOUCH CHECK SOURCE WITH BARE HAND.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
THIS CHECK SOURCE IS PROVIDED WITH ION CHAMBER, P/N C-7757. THIS ION
CHMBER IS FOUND ON RADIACMETER, P/N SM400, NSN 6665-01-157-3780.
REFERENCE DATA/LITERATURE-T.O. 11H4-7-15-1. MFR REP, MR. TERRY SCH
WAGER, 16 OCT 1996 STATED THAT THERE ISNO MSDS REQUIRED BUT ONE
PROVIDED FOR INFO ONLY.

Chemical Properties

HCC:A2
Boiling Pt:B.P. Text:8132F,4500C
Spec Gravity:18.95
Solubility in Water:INSOLUBLE.
Appearance and Odor:THORIUM METAL FOUND IN CHECK SOURCE PROVIDED WITH
ION CHAMBER (P/N C-7757).

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH CHLORINE, SULFUR, PHOSPHORUS AND CONCENTRATED ACIDS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF IAW LOCAL, STATE & FEDERAL
ENVIRONMENTAL REGULATIONS (TITLE 10 CFR). DOD PERSONNEL-REMOVE
CHECK SOURCE & DISPOSE OF THROUGH YOUR SERVICE LOW LEVEL
RADIOACTIVE WASTE SOURCE POC; THEN TURN IN IONIZATION CHAMBER W/O
CHECK SOURCE TODRMO.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.