CCGLB - 6036200 INITIATOR,ONE-WAY TRANSFER EXPLOSIVE ACTUATED

  • MSDS: CCGLB
  • Manufacturer: SCOT INC
  • Product Name: 6036200 INITIATOR,ONE-WAY TRANSFER EXPLOSIVE ACTUATED
  • National Stock Number: 1377-01-167-6621
Product Identification

Product ID:6036200 INITIATOR,ONE-WAY TRANSFER EXPLOSIVE ACTUATED
MSDS Date:11/27/1991
FSC:1377
NIIN:01-167-6621
MSDS Number: CCGLB

Responsible Party
SCOT INC.
2525 CURTISS ST
DOWNERS GROVE, IL 60515-0705
US

Emergency Phone: 800-535-5053

Info Phone: 708-969-0620

Preparer: NICHOLAS F TURCIC

Cage: MO896

Contractor
SCOT INC.
DOWNERS GROVE, IL 60515-0705 US

Telephone: 708-969-0620

Cage: MO896

Ingredients

LEAD AZIDE

CAS: 13424-46-9

RTECS: OF8650000

Fraction By Weight: 40%


HNS HEXANITROSTILBENE

Fraction By Weight: 60%


ALUMINUM HOUSING

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE

First Aid

First Aid:OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:USE WATER ONLY. FOR LARGE FIRES, FLOOD AREA W/WATER
FROM A DISTANCE.
Fire Fighting Procedures:MOVE CONTAINER W/O RISK. APPLY COOLING WATER
TO SIDES, UNTIL FIRE IS OUT. IN CARGO AREA, USE UNMANNED HOSE
HOLDER/MONITOR NOZZLES. WITHDRAW & LET FIRE BURN.
Unusual Fire/Explosion Hazard:IF INITIATOR IS INITIATED SOME LIGHT
METALLIC FRAGMENTATION WOULD OCCUR W/A HOT DISCHARGE THAT WOULD
POSE A FIRE HAZARD. (SEE SUPP)

Accidental Release

Spill Release Procedures:USE FLOODING QUANTITIES OF WATER AS FOG. COOL
CONTAINERS W/FLOODING AMOUNTS OF WATER, APPLY FROM AS FAR A
DISTANCE AS POSSIBLE. EVACUATE TO A RADIUS OF 1500 FEET.

Handling

Handling and Storage Precautions:USE CAUTION IN HANDLING ACTUATED
DEVICE SURFACE TEMP MAY BE 200F.
Other Precautions:KEEP FIRE AWAY.

Exposure Controls

Supplemental Safety and Health
MODERATE EXPLOSION HAZARD WHEN SHOCKED/EXPOSED TO HEAT.

Stability

Stability Indicator/Materials to Avoid:YES
NOXIOUS GASES
Stability Condition to Avoid:HEAT, FLAME, SHOCK

Disposal

Waste Disposal Methods:DISPOSAL OF WASTE IS PERFORMED BY QUALIFIED
DEMOLITION PERSONNEL IAW/FEDERAL, STATE & LOCAL REGULATIONS.
EXPLOSIVE CLASS C UN0173.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.