CCJCR - PENAIR M-5575

Product Identification

Product ID:PENAIR M-5575
MSDS Date:10/07/1993
FSC:6850
NIIN:01-248-9831
MSDS Number: CCJCR

Responsible Party
PENETONE CORP SUB OF WEST CHEMICAL PRODUCTS INC
74 HUDSON AVENUE
TENAFLY, NJ 07670-1017
US

Emergency Phone: 201-567-3000/800-424-9300(CHEMTREC)

Info Phone: 201-567-3000

Cage: 56883

Contractor
PENETONE CORP
TENAFLY, NJ 07670 US

Telephone: 201-567-3000

Cage: 56883

Ingredients

PETROLEUM HYDROCARBON;(ALIPHATIC HYDROCARBONS)

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 8.2%


HEAVY AROMATIC NAPHTHA (SOLVENT NAPHTHA); (AROMATAIC

CAS: 64742-94-5

RTECS: WF3100000

Fraction By Weight: 8.2%


WATER

CAS: 7732-18-5

RTECS: ZC0110000


SURFACTANTS (MIXTURE-ANIONIC & NONIONIC)


DIETHYLENE GLYCOL MONOBUTYL ETHER

CAS: 112-34-5

RTECS: KJ9100000

Fraction By Weight: <5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CAN BE IRRIT TO EYE/SKIN/RESP
TRACT.EYE:SLIGHTLY IRRIT BUT DOES NOT INJURE TISSUE.HI VAP CONC MAY
BE IRRIT.SKIN:FREQ/PROL CONTACT MAY IRRIT/DRY SKIN,CAUSE
DERM.INHAL:HI VAP/AEROSOL CONC(>TLV)IRRIT RES P
TRACT,HEADACHES,DIZZ,ANESTHESIA,DROWS,UNCONSC,OTHER CNS
EFFECTS.INGEST:SM AMTS INTO LUNGS BY SWALLOW/VOMIT.(SUPPLEMEN)
Effects of Overexposure:IRRIT EYE/SKIN/RESP TRACT. SLIGHTLY IRRIT EYE.
IRRIT,DRY SKIN, DERMATITIS. IRRIT RESP TRACT, HEADACHES, DIZZINESS,
ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS, OTHER CNS EFFECTS.
SEVERE/DELAYED HEALTH EFF ECTS SUCH AS INFLAMMATION OF LUNGS,
INFECTION OF BRONCHI. IRRIT DIGESTIVE TRACT, DIARRHEA.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS CONDITION.

First Aid

First Aid:EYE:FLUSH W/LG AMTS OF WTER.SEE PHYSICIAN IMMED. SKIN:FLUSH
W/LG AMTS OF WATER.USE SOAP IF AVAILABLE.REMOVE CONTAMIN
CLOTH.IRRIT DEVELOPS/PERSIST CONSULT PHYSICIAN.INHAL:REMOVE TO
FRESH AIR.ADMINISTER OXY OR ART RESP AS NEEDED.CALL PHYSICIAN
IMMED.INGEST:DO NOT INDUCE VOMIT.USE STOMACH PUMP.CALL PHYSICIAN
IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:145F,63C
Autoignition Temp:Autoignition Temp Text:N/DETR
Lower Limits:NOT DETERMIN
Upper Limits:NOT DETERMIN
Extinguishing Media:EXTINGUISH W/WATER, FOAM, OR DRY CHEMICAL.
Fire Fighting Procedures:EITHER ALLOW FIRE TO BURN OUT UNDER CONTROLLED
CONDITIONS OR EXTINGUISH W/WATER,FOAM,OR DRY CHEMICAL.
Unusual Fire/Explosion Hazard:COMBUSTIBLE.CAN FORM COMBUSTIBLE MIXTURES
@OR ABOVE FLASH POINT.CNTNRS CAN RUPTURE & EXPLODE UNDER FIRE
CONDITIONS DUE TO PRESSURE & VAPOR BUILDUP.

Accidental Release

Spill Release Procedures:LAND:REMOVE IGN SOURCE.USE ABSORB
MATL(TOWELS,ABSORB POWDERS).PUT MATL INTO PROPER WASTE DISPO CNTNR
W/LID TIGHTLY COVERED.SOLVT SOAK MATL MAY SPONT
COMBUST.DIKE/RECOVER/USE ABSORB TO DRY AREA.RINSE W
/WATER.WATER:SKIM/SUITABLE ABSORB.CONTAINS (SUPPL)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORAGE TEMP:AMBIENT.DO NOT STORE
ABOVE 120F.KEEP AWAY FROM HEAT SOURCES,OPEN FLAMES,OTHER IGN
SOURCES.DO NOT STORE NEAR STRONG OXIDANTS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:AN ORGANIC VAPOR MASK SHOULD BE USED IF TLV IS
EXCEEDED & PARTICLE MASK IF PRODUCT IS SPRAYED.DO NTO MIST PRODUCT.
USE COARSE SPRAY ONLY.
Ventilation:NONE NEEDED UNDER NORMAL USE CONDITIONS.ENCLSD AREA/LG AMTS
OF PROD BEING USED USE OF FANS/OTHER MECH VENTI RECOMMENDED.
Protective Gloves:SOLVENT RESIST GLOVDS.
Eye Protection:SAF GLASSES,SPLASH PROOF GOGG,FCSHIELDS.
Other Protective Equipment:RUBBER BOOTS, APRONS, GAUNTLETS, RAINGEAR
SHOULD BE WORN DEPENDING ON HOW PRODUCT USED.
Work Hygienic Practices:LAUNDER CONTAMIN CLOTH BEF REUSE.
Supplemental Safety and Health
HEALTH HAZ:MAY CAUSE SEVERE/DELAYED HEALTH EFFECTS SUCH AS INFLAMM OF
LUNGS,INFECTION OF BRONCHI.MAY IRRIT DIGESTIVE TRACT,DIARRHEA.
SPILL:SURFACTNAT-CAUSE DISPERSE IN WATER.LOC HI CONC MAY CAUSE FISH
KILLS BUT NO PERSISTEN/LONG TERM EFFECTS RESULT.CHECK W/LOC ENVIRO
REG AGENCIES FOR REPORT REQMTS.

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:=WATER
Vapor Density:N/DETERMIN
Spec Gravity:0.98 @75F
pH:8-9
Viscosity:NP
Evaporation Rate & Reference:<0.05 (N-BUTYL ACETATE=1)
Solubility in Water:EMULSIFIES.
Appearance and Odor:CLEAR BLUE VISCOUS LIQUID W/MILD HYDROCARBON
SOLVENT ODOR.
Percent Volatiles by Volume:20
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SMIKE,FUMES,OXIDES OF CARBON.

Disposal

Waste Disposal Methods:NONE SPEC BY MFG.RCRA HAZ CLASS:NON-HAZ WASTE.NO
CERCLA MATLS;RECOMMEND CONTACT LOC AUTHORITIES TO DETERMINE IF
THERE MAY BE OTHER LOC REPORTING REQMTS.SARA TITLE III 313
CHEM:DIETHYLENE GLYCOL MONOBU TYL ETHER <5%. HMIS:FOLLOW ALL
APPLICABLE LAWS/REG

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.