CCJDX - UNKNOWN (NO PART NUMBER OR TRADE NAME LISTED ON MSDS)

  • MSDS: CCJDX
  • Manufacturer: TADIRAN ELECTRONIC INDUSTRIES
  • Product Name: UNKNOWN (NO PART NUMBER OR TRADE NAME LISTED ON MSDS)
  • National Stock Number: 6135-01-301-8776
Product Identification

Product ID:UNKNOWN (NO PART NUMBER OR TRADE NAME LISTED ON MSDS)
MSDS Date:07/06/1995
FSC:6135
NIIN:01-301-8776
MSDS Number: CCJDX

Responsible Party
TADIRAN ELECTRONIC INDUSTRIES
40 SEAVIEW BLVD
PORT WASHINGTON, NY 11050
US

Emergency Phone: 516-621-4980

Info Phone: 4087271-4980

Cage: 0BYG1

Contractor
TADIRAN ELECTRONIC INDUSTRIES
PORT WASHINGTON, NY 11050 US

Telephone: 516-621-4980

Cage: 0BYG1

Ingredients

LITHIUM (METAL)

CAS: 7439-93-2

RTECS: OJ5540000


THIONYL CHLORIDE

CAS: 7719-09-7

RTECS: XM5150000

Fraction By Weight: 50%

OSHA PEL C 1 PPM

ACGIH TLV: C 1 PPM; 9495


SULFUR DIOXIDE (SARA 302)

CAS: 7446-09-5

RTECS: WS4550000

OSHA PEL 5 PPM

ACGIH TLV: 2 PPM/5 STEL; 9495

Hazards

LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:CORROSIVE LIQUID, CAUSES BURNS,
HARMFUL IF INHALED.
Explanation of Carcinogenicity:MFR GAVE THE ABOVE LISTINGS ON THE MSDS
BUT NO OTHER COMMENTS WERE RECORDED ON THE MSDS.

First Aid

First Aid:SEEK MEDICAL ASSISTANCE FOR FURTHER TREATMENT, OBSERVATION &
SUPPORT IF NECESSARY.

Fire Fighting

Extinguishing Media:LIT-X-EXTINGUISHER
Fire Fighting Procedures:NO WATER ALLOWED (APPLICABLE FOR WAREHOUSE).
USE MANUFACTURER'S RECOMMENDED PROCEDURES.
Unusual Fire/Explosion Hazard:RELEASE OF SULFUR DIOXIDE, HYDROGEN AND
HYDROCHLORIC ACID, IF OPENED.

Accidental Release

Spill Release Procedures:GET FULL PROTECTIVE EQUIPMENT. USE LARGE
CONTAINER FILLED W/OIL, FILTERED MASKS. VENTILATE THE CONTAMINATED
AREA.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

Handling

Handling and Storage Precautions:SPECIFIED BY U.L.:WARNING! FIRE,
EXPLOSION & SEVERE BURN HAZARD. DO NOT RECHARGE, DISASSEMBLE, HEAT
ABOVE 212F, INCINERATE OR EXPOSE CONTENTS TO WATER
Other Precautions:MFR GAVE NO INFORMATION ON MSDS.

Exposure Controls

Work Hygienic Practices:MFR GAVE NO INFORMATION ON MSDS. IF CONTACT
W/INTERNALS OCCUR, USE STRICT CHEMICAL HYGIENE PROCEDURES.
Supplemental Safety and Health
MSDS RECEIVED FROM NAVY (FOCAL POINT N). NAVY IDENTIFIED THE NSN & CAGE
CODE.

Chemical Properties

HCC:N1
NRC/State Lic Num:NONE

Stability

Stability Indicator/Materials to Avoid:YES
INTERNAL CONTENTS W/WATER.
Stability Condition to Avoid:FIRE, HEATING ABOVE 150C.
Hazardous Decomposition Products:SUFUR DIOXIDE, HYDROGEN CHLORIDE,
HYDROGEN
Conditions to Avoid Polymerization:WILL NOT OCCUR. EXPOSURE TO INTERNAL
MATERIALS.

Disposal

Waste Disposal Methods:BURY IN GROUND 1 METER DEEP, DISPOSE OF
W/SPECIAL EQUIPMENT OR USE PROFESSIONAL BATTERY DISPOSAL SERVICE.
DISPOSAL SERVICES BY B.D.T. 716-634-6794. HMIS:DISPOSE I/A/W
FEDERAL, STATE & LOCAL REGULATION S.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.