CCLQC - RATION HEATING/FUEL,COMPRESSED,TRIOXANE,MIL-F-10805D
- MSDS: CCLQC
- Manufacturer: TRUETECH INC (FORMERLY CHEMICAL COMPOUNDING CORP )
- Product Name: RATION HEATING/FUEL,COMPRESSED,TRIOXANE,MIL-F-10805D
- National Stock Number: 9110-00-263-9865
Product Identification
Product ID:RATION HEATING/FUEL,COMPRESSED,TRIOXANE,MIL-F-10805D
MSDS Date:01/21/1997
FSC:9110
NIIN:00-263-9865
MSDS Number: CCLQC
Responsible Party
RIVERHEAD, NY 11901-2555
US
Emergency Phone: 516-727-8600
Info Phone: 516-727-8600 516-727-7592(FAX)
Preparer: DSCR-VBA(LEVIEN)
Cage: KO155
Contractor
Telephone: 516-727-8600
Cage: KO155
Ingredients
TRIOXANE
CAS: 110-88-3
Fraction By Weight: 95%
OSHA PEL 5MG/M3 (RESPIR DUST)
ACGIH TLV: 10MG/M3 (TOTAL DUST)
METHYLENE BLUE(INGREDIENT 2 AND INGREDIENT 3 = 5%)
CAS: 61-73-4
RTECS: SO5600000
MAGNESIUM STEARATE(INGREDIENT 2 AND INGREDIENT 3 = 5%)
CAS: 557-04-0
RTECS: WI4390000
Hazards
LD50 LC50 Mixture:ORAL LD50 (RAT) IS 5G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE SEVERE EYE INJURY.MAY CAUSE
RESPIRATORY IRRITATION.BURNING RELEASES FORMALDEHYDE.
Explanation of Carcinogenicity:FORMALDEHYDE(A DECOMPOSITION PRODUCT) IS
LISTED NTP,IARC AND OSHA.
Effects of Overexposure:INHAL(FORMALDEHYDE):BURNING SENSATION,TEARING.
Medical Cond Aggravated by Exposure:PERSONS WITH PREEXISTING
RESPIRATORY CONDITIONS MAY BE ADVERSELY AFFECTED BY THIS PRODUCT.
First Aid
First Aid:SKIN:REMOVE CONTAMINATED CLOTHING.WASH WITH WATER.GET MEDICAL
ATTENTION.EYES:WASH WITH WATER.GET MEDICAL ATTENTION.INHAL:REMOVE
FROM EXPOSURE.GIVE OXYGEN OR CPR IF NEEDED.GET MEDICAL
ATTENTION.INGEST: GET PROMPT QUALIFIED MEDICAL ATTENTION.IF
CONSCIOUS,RINSE MOUTH WITH WATER,THEN DRINK 2 GLASSES OF WATER.
Fire Fighting
Flash Point Method:OC
Flash Point:113F,45C
Lower Limits:3.6
Upper Limits:29
Extinguishing Media:WATER SPRAY,CARBON DIOXIDE,DRY CHEMICAL,FOAM.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL FIREFIGHTING GEAR.
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES.
Accidental Release
Spill Release Procedures:ELIMINATE SOURCES OF IGNITION.USE PROPER
RESPIRATORY AND PROTECTIVE EQUIPMENT.SWEEP INTO A DUSTPAN;PLACE IN
APPROPRIATE CONTAINER FOR DISPOSAL.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
AREA.KEEP CONTAINER TIGHTLY CLOSED.KEEP AWAY FROM SOURCES OF
IGNITION.
Other Precautions:ANYDROUS CONDITIONS CAUSE SLOW POLYMERIZATION.HEAT
ABOVE 300F GENERATES FORMALDEHYDE.SUBLIMES IN THE PRESENCE OF AIR.
Exposure Controls
Respiratory Protection:IF HEATED ABOVE 300F OR WHILE IN CONFINED SPACES
USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:USE LOCAL EXHAUST.
Protective Gloves:RUBBER,NEOPRENE.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:PROVIDE A LOCAL EYE WASH STATION AND SAFETY
SHOWER.
Work Hygienic Practices:USE REASONABLE CARE IN HANDLING THIS ITEM.
Supplemental Safety and Health
HMIS SPOKE TO MARK LAMENSDORF AT TRUTECH ON 21JAN97.THE MSDS WAS
PREPARED FOR A TECHNICAL SUPPORT REQUEST,USING THE BEST AVAILABLE
INFORMATION.THE PEL FOR FORMALDEHYDE IS 0.75PPM(TWA-8HR);2PPM
STEL;TL V IS 0.3PPM(CEILING).
Chemical Properties
HCC:F8
Boiling Pt:B.P. Text:238F,114C
Melt/Freeze Pt:M.P/F.P Text:142F,61C
Vapor Pres:10
Vapor Density:<1.2
Spec Gravity:1.17
Solubility in Water:APPRECIABLE
Appearance and Odor:BARS.WHITE SOLID NEEDLE-LIKE PRISMATIC
CRYSTALS,SWEET ODOR.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS AND STRONG MINERAL ACIDS.
Stability Condition to Avoid:HIGH HEAT.FORMALDEHYDE IS PRODUCED ABOVE
302F.THIS MATERIAL SUBLIMES WHEN EXPOSED TO AIR.
Hazardous Decomposition Products:CARBON MONOXIDE,CARBON
DIOXIDE,FORMALDEHYDE,PARAFORMALDEHYDE.
Conditions to Avoid Polymerization:POLYMERIZES SLOWLY UNDER ANHYDROUS
CONDITIONS(AN ENVIRONMENT WITHOUT WATER).
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.INCINERATION IS RECOMMENDED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.