CCPZL - IMRON 5000 POLYURETHANE ENAMELS, 519H

  • MSDS: CCPZL
  • Manufacturer: E I DUPONT DE NEMOURS AND CO
  • Product Name: IMRON 5000 POLYURETHANE ENAMELS, 519H
  • National Stock Number: 8010-00N073991
Product Identification

Product ID:IMRON 5000 POLYURETHANE ENAMELS, 519H
MSDS Date:01/01/1995
FSC:8010
NIIN:00N073991
MSDS Number: CCPZL

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

ACRYLIC POLYMER A

CAS: 42767-92-0

OSHA PEL N/K

ACGIH TLV: N/K


ACRYLIC POLYMER B

CAS: 42767-92-0

OSHA PEL N/K

ACGIH TLV: N/K


ANTHRAQUINONE PIGMENT

OSHA PEL N/K

ACGIH TLV: N/K


8.0

CAS: 123-86-4

RTECS: AF7350000

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM/200STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2.2 @ 20C

CAS: 110-43-0

RTECS: MJ5075000

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE

CAS: 108-65-6

RTECS: AI8925000

OSHA PEL N/K

ACGIH TLV: N/K


25.0 @ 20C

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HIGH CONCS HAVE

RTECS: 9999999ZZ


OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. CAN BE

RTECS: 9999999ZZ


TO SIT 10 MIN, MIN. TYPICAL DECONTAM SOLNS ARE

RTECS: 9999999ZZ


AMMONIA, 2-5% DETERGENT, BALANCE WATER. THIS

RTECS: 9999999ZZ


AFTER 48 HOURS, CONTAINER MAY BE SEALED AND

RTECS: 9999999ZZ


PROBLEMS/PRIOR RXN TO ISOCYANATES SHOULD NOT

RTECS: 9999999ZZ


PROT IN PAINTING AREA. FOLLOW THE RESPIRATOR

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC:INGEST:GI DISTRESS.
INHAL:MAY CAUSE NOSE & THROAT IRRIT. RPTD & PRLNG OVEREXP TO SOLVS
MAY LEAD TO PERM BRAIN & NERV SYS DMG. EYE WATERING, HDCH, NAUS,
DIZZ & LOSS OF COORD ARE SIGNS THA T SOLV LEVELS ARE TOO HIGH.
EXPOS TO ISOCYANATES MAY CAUSE RESP SENSIT. THIS EFT MAY BE PERM,
MAY BE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:DELAYED FOR SEVERAL HRS AFTER EXPOS.
RPTD OVEREXP TO ISOCYANATES MAY CAUSE A DECR IN LUNG FUNC WHICH MAY
BE PERM. MAY CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNG LIQ CONT MAY
CAUSE SKIN IRRIT W/D ISCOMFORT & DERM. BUTYL ACETATE:MAY CAUSE
ABNORM LIVER FUNC. TESTS FOR EMBRYOTOX ACTIVITY IN ANIMALS HAS BEEN
(SUP DAT)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH OR BREATHING
PROBLEMS OR PRIOR REACTION TO ISOCYANATES MUST NOT BE EXPOSED TO
VAPORS OR SPRAY MIST OF THIS PRODUCT.

First Aid

First Aid:INGESTION: IN THE UNLIKELY EVENT OF INGESTION, CALL MD IMMED
& HAVE NAMES OF INGREDIENTS AVAILABLE. INHALATION: IF AFFECTED BY
INHALATION OF VAPOR/SPRAY MIST, REMOVE TO FRESH AIR. IF BREATHING
DIFFICU LTY PERSISTS/OCCURS LATER, CONSULT MD. EYES: IMMED FLUSH
W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. CALL MD. SKIN: WASH
W/SOAP & WATER. IF IRRITATION OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:73.0F,22.8C
Lower Limits:0.9%
Upper Limits:23.0%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH POINT, EMITS
FLAMMABLE VAPS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAMMABLE AT TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:DO NOT BREATHE VAPS. DO NOT GET IN EYES/SKIN.
WEAR POS PRESS SUPP AIR VAP/PARTICULATE RESP (NIOSH APPRVD), EYE
PROT, GLOVES & PROT MATL. REMOVE SOURCES OF IGNIT. ABSORB W/INERT
MATL. VENT AREA. POUR L IQ DECONTAMINATE SOLN OVER SPILL & ALLOW
(ING 11)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS, AND FLAME. CLOSE CONTAINER AFTER EACH USE.
GROUND CONTAINERS WHEN POURING.
Other Precautions:DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT,
BRAZE OR WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR
APPROPRIATE VENTILATION.

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR POS PRESS SUPP
AIR RESP (NIOSH APPRVD TC-19C) WHILE MIXING ACTIVATOR W/ANY
PAINT/CLEAN ENAMEL, DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS
ARE EXHAUSTED. INDIVIDUAL S W/HISTORY OF LUNG/BRTHG (ING 14)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . COVERALLS RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
EFTS OF OVEREXP: INCONCLUSIVE. HAS BEEN TOX TO FETUS IN LAB ANIMALS AT
DOSES THAT ARE TOX TO MOTHER. METHYL AMYL KETONE:INGEST STUDIES ON
LAB ANIMALS SHOWED THAT VERY HIGH ORAL DOSES CAUSED INCRD LIVE R &
KIDNEY WTS. PROPYLENE GLYCOL MONOMETHYL ETHER ACETATE:MAY CAUSE MOD
EYE BURNING. RECURRENT OVEREXP MAY RSLT (ING 9)

Chemical Properties

Boiling Pt:B.P. Text:>135F,>57C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.99
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:7-100

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE, OXIDES OF HEAVY METALS IN INGREDIENTS SECTION.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE, AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.