CCRHM - IMRON 5000 POLYURETHANE ENAMELS, 528H

  • MSDS: CCRHM
  • Manufacturer: E I DUPONT DE NEMOURS AND CO
  • Product Name: IMRON 5000 POLYURETHANE ENAMELS, 528H
  • National Stock Number: 8010-00N073996
Product Identification

Product ID:IMRON 5000 POLYURETHANE ENAMELS, 528H
MSDS Date:01/01/1995
FSC:8010
NIIN:00N073996
MSDS Number: CCRHM

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET STREET
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

ACRYLIC POLYMER A

CAS: 42767-92-0

OSHA PEL N/K

ACGIH TLV: N/K


ACRYLIC POLYMER I

CAS: 25766-58-9

OSHA PEL N/K

ACGIH TLV: N/K


8.0 @

CAS: 123-86-4

RTECS: AF7350000

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM/200STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2.2 @ 20C

CAS: 110-43-0

RTECS: MJ5075000

OSHA PEL N/K

ACGIH TLV: N/K


CI PIGMENT ORANGE; (MONOAZZO PIGMENT)

CAS: 12236-62-3

OSHA PEL N/K

ACGIH TLV: N/K


ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE

CAS: 108-65-6

RTECS: AI8925000

OSHA PEL N/K

ACGIH TLV: N/K


THIS PROD. DO NOT PERMIT ANYONE W/OUT PROT IN

RTECS: 9999999ZZ


HAS BEEN INCONCLUSIVE. HAS BEEN TOX TO

RTECS: 9999999ZZ


INGEST STUDIES ON LAB ANIMALS

RTECS: 9999999ZZ


KIDNEY WEIGHTS. PROPYLENE GLYCOL MONOMETHYL ETHER

RTECS: 9999999ZZ


OVEREXPOSURE MAY RESULT IN LIVER AND KIDNEY INJURY.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:GI DISTRESS. INHAL:MAY CAUSE
NOSE & THROAT IRRIT. RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD TO
PERM BRAIN & NERV SYS DMG. EYE WATERING, HDCHS, NAUS, DIZZ & LOSS
OF COORD ARE SIGNS THAT SOLV LEVEL S ARE TOO HIGH. EXPOS TO
ISOCYANATES MAY CAUSE RESP SENSIT. EFTS MAY BE PERM. EFT MAY BE
DELAYED FOR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:SEVERAL HRS AFTER EXPOS. RPTD OVEREXP
TO ISOCYANATES MAY CAUSE DECR IN LUNG FUNCTION WHICH MAY BE PERM.
SKIN/EYE CONT:MAY CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT
MAY CAUSE SKIN IRR IT W/DISCOMFORT & DERM. BUTYL ACETATE:MAY CAUSE
ABNORMAL LIVER FUNCTION. TESTS FOR EMBRYOTOX ACTIVITY IN
ANIMALS(ING 9)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH BREATHING PROBLEMS
OR PRIOR REACTION TO ISOCYANATES MUST NOT BE EXPOSED TO VAPORS OR
SPRAY MIST OF THIS PRODUCT.

First Aid

First Aid:INGESTION:IN THE UNLIKELY EVENT OF INGESTION CALL MD IMMED &
HAVE NAMES OF INGREDIENTS AVAILABLE. INHALATION:IF AFFECTED BY
INHALATION OF VAPOR/SPRAY MIST, REMOVE TO FRESH AIR. IF BREATHING
DIFFICULTY PERSISTS/OCCURS LATER, CONSULT MD. EYES:IMMEDIATELY
FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES; CALL MD. SKIN:WASH
WITH SOAP AND WATER. IF IRRITATION OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:100F,38C
Lower Limits:0.9%
Upper Limits:23.0%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILDUP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAMMABLE VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAM @ TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:DO NOT BRTHE VAPS, GET IN EYES/ON SKIN. WEAR
POS PRESS SUPP AIR VAP/PARTICULATE RESP (NIOSH TC-19C APPRVD), EYE
PROT, GLOVES & PROT MATL. REMOVE SOURCES OF IGNIT. ABSORB W/INERT
MATL. VENT AREA. POUR LIQ DECONTAM SOLN OVER SPILL & ALLOW
TO(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING.
Other Precautions:DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT,
BRAZE OR WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR
APPROPRIATE VENTILATION.

Exposure Controls

Respiratory Protection:DO NOT BRTHE VAPS/MISTS. WEAR POS PRESS SUPP AIR
RESP (NIOSH (TC-19C)/APPRVD) WHILE MIXING ACTIVATOR W/ANY
PAINT/CLEAR ENAMEL, DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS
ARE EXHSTED. INDIVIDUALS W/HISTORY OF LUNG/BRTHG PROBLEMS(SUPDAT)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES ARE RECOMMENDED.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
SPILL PROC:SIT 10 MIN, MIN. TYPICAL DECONTAM SOLNS ARE:20% SURFACTANT
(TERGITOL TMN 10), 80% WATER, 0-10% AMMONIA, 2-5% DETERGENT,
BALANCE WATER. THIS PROCEDURE CAN GENERATE PRESS. DO NOT SEAL
CNTNR. AFTER 48 HRS, CNTNR MAY BE SEALED & DISP OF. RESP PROT:OR
PRIOR RXN TO ISOCYANATE SHOULD NOT USE/BE EXPOSED TO (ING 8)

Chemical Properties

Boiling Pt:B.P. Text:>135F,>57C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.09
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:7-100

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS IN HAZARDOUS INGREDIENTS.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE CLOSED
CONTAINERS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.