CCSCK - TONER KIT 8/15 (150 GRAMS), 5397-30

  • MSDS: CCSCK
  • Manufacturer: RICOH CORP
  • Product Name: TONER KIT 8/15 (150 GRAMS), 5397-30
  • National Stock Number: 6850-00N074685
Product Identification

Product ID:TONER KIT 8/15 (150 GRAMS), 5397-30
MSDS Date:08/01/1995
FSC:6850
NIIN:00N074685
MSDS Number: CCSCK

Responsible Party
RICOH CORP
5 DEDRICK PLACE
WEST CALDWELL, NJ 07006
US

Emergency Phone: 800-336-6737

Info Phone: 800-336-6737; 201-882-2000

Cage: RICOH

Contractor
RICOH CORP
WEST CALDWELL, NJ 07006 US

Telephone: 201-882-2000

Cage: RICOH

Ingredients

CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: <5%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


IRON (III) OXIDE; (IRON OXIDE)

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: 50-60%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3 FUME (FE)


SOLVENT BLACK 7; (DYE)

CAS: 8005-02-5

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


STYRENE/ACRYLATE POLYMER; (STYRENE ACRYLIC POLYMER)

CAS: 25213-39-2

Fraction By Weight: 40-50%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES/INHAL:NOT APPLIC.
SKIN:IRRIT (RABBIT) - MILDLY IRRITATING. INGEST:>5 G/KG BODYWEIGHT.
CHRONIC:IN A XEROX SPONSORED CHRONIC INHAL STUDY IN RATS USING A
SPECIAL TEST TONER, THERE WERE NO LUNG CHANGES AT ALL IN LOWEST
EXPOS LEVEL (1 MG/M3), MOST RELEVANT LEVEL TO POTNTL HUMAN EXPOS. A
VERY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK:IARC MONOGRAPHS ON EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 65, PG 24-27, 1995:GROUP 2B.
Effects of Overexposure:HLTH HAZ:SLIGHT DEGREE OF FIBROSIS WAS NOTED IN
25% OF ANIMALS AT MIDDLE EXPOS LEVEL (4 MG/M3) WHILE A SLIGHT
DEGREE OF FIBROSIS WAS OBSERVED AT HIGHEST EXPOS LEVEL (16 MG/M3)
IN ALL ANIMALS. THESE FI NDINGS ARE ATTRIBUTED TO "LUNG
OVERLOADING", A GENERIC RESPONSE TO EXCESSIVE AMTS OF ANY DUST
RETAINED IN LUNGS (SUPDAT)
Medical Cond Aggravated by Exposure:WILL NOT OCCUR.

First Aid

First Aid:EYES:TRY TO REMOVE OR FLUSH OUT W/EYE DROPS FOR AT LEAST 15
MINUTES. IF UNSUCCESSFUL, GET MEDICAL ATTENTION. SKIN:WASH
THOROUGHLY W/SOAP & WATER. INHAL:REMOVE FROM EXPOSURE.
INGEST:DILUTE STOMACH CONT ENTS W/SEVERAL GLASSES OF WATER.

Fire Fighting

Extinguishing Media:FOAM, WATER SPRAY, DRY CHEMICALS OR CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NO SPECIAL FIRE-FIGHTING PROCEDURE IS NECESSARY.
Unusual Fire/Explosion Hazard:WILL NOT OCCUR.

Accidental Release

Spill Release Procedures:IF SPILLED, SWEEP UP USING APPRVD TONER VACUUM
CLEANER W/0.5 MICRON FILTER SUCH AS ATRIX AAA TONER VACUUM (RICOH
EDP CODE 342MIU). USE OF VACUUM CLEANER NOT RATED FOR TONER
PARTICULATE COULD BE POTNTL FIRE HAZ &/OR RSLT IN PERSONAL
INJURY.(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP OUT
OF REACH OF CHILDREN. MINIMIZE BREATHING DUST.
Other Precautions:IN ORDER TO AVOID RISK OF POWDER ENTERING EYES, DO
NOT HANDLE IN WINDY AREAS. MINIMIZE INHALATION OF DUST.

Exposure Controls

Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE NEEDED UNDER NORMAL CONDITIONS OF USE.
Ventilation:LOCAL EXHAUST:NONE NEEDED UNDER NORMAL CONDITIONS OF USE.
MECHANICAL (GENERAL):ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . NONE NEEDED UNDER NORMAL CONDITIONS OF USE.
Work Hygienic Practices:CLEANSE SKIN THOROUGHLY AFTER CONTACT, BEFORE
BREAKS & MEALS, & AT THE END OF WORK PERIODS.
Supplemental Safety and Health
EFTS OF OVEREXP:FOR PRLNG INTERVAL. SPECIAL TEST TONER WAS TEN TIMES
MORE RESPIRABLE THAN COMMERCIALLY AVAIL TONER TO COMPLY W/EPA
TESTING PROTOCOL & WOULD NOT FUNCTION PROPERLY IN XEROGRAPHIC
EQUIP. SPILL PROC:REMOVE RESIDUE W/SOAP & WATER. WASTE DISP
METH:PROPER METHOD OF DISPOSAL.

Chemical Properties

Spec Gravity:1.99
Solubility in Water:NEGLIGIBLE; <0.1%
Appearance and Odor:BLACK POWDER; NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CARBON MONOXIDE & OTHER DECOMPOSITION
PRODUCTS IN THE CASE OF INCOMPLETE COMBUSTION.

Disposal

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . USED
TONER SHOULD BE DISP OF IN ENVIRONMENTALLY SAFE MANNER & I/A/W GOVT
REGS. DO NOT INCIN. DISP REGS VARY FROM LOCALITY TO LOCALITY,
THEREFORE, CONSU LT YOUR LOC OFFICE OF THE EPA TO DETERMINE(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.