CCSVR - K-311 BATTERY

  • MSDS: CCSVR
  • Manufacturer: ACR ELECTRONICS INC
  • Product Name: K-311 BATTERY
  • National Stock Number: 6135-01-050-3193
Product Identification

Product ID:K-311 BATTERY
MSDS Date:04/04/1996
FSC:6135
NIIN:01-050-3193
Kit Part:Y
MSDS Number: CCSVR

Responsible Party
ACR ELECTRONICS INC
5757 RAVENSWOOD RD
FT LAUDERDALE, FL 33312
US

Emergency Phone: 305-981-3333

Info Phone: 305-981-3333

Cage: 18560

Contractor
ACR ELECTRONICS INC
FT. LAUDERDALE, FL 33312 US

Telephone: 305-981-3333

Cage: 18560

Ingredients

POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 5-9%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


MANGANESE DIOXIDE

CAS: 1313-13-9

RTECS: OP0350000

Fraction By Weight: 32-38%

OSHA PEL 5 MG MN/M3 CEILING

ACGIH TLV: 5 MG MN/M3


ZINC (SARA 313) (CERCLA)

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 11-16%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE EFFECTS-AN CAUTE EXPOSURE WILL
NOT GENERALLY AGGRAVATED BY ANY MEDICAL CONDITION. CHRONIC
EFFECTS-THESE CHEMICALS ARE CONTAINED IN SEALED CAN. RISK OF
EXPOSURE OCCURS ONLY IF THE BATTERY IS MECH ANICALLY OR ELCTRICALLY
ABUSED. MOST LIKELY RSIK IS WHEN CELLS LEAKS.
Explanation of Carcinogenicity:IARC, NTP, AND OSHA DO NOT LIST K-311
BATTERY AS A CARCINOGEN.
Effects of Overexposure:POTASSIUM HYDROXIDE IS CAUSTIC AND SKIN CONTACT
CAN CAUSE IRRITATION OR BURNS. EYE CONTACT WITH POTASSIUM HYDROXIDE
MAY CAUSE PERMANENT INJURY.

First Aid

First Aid:INHALATION-REMOVE INDIVIDUAL TO FRESH AIR. EYE-FLUSH WITH
COPIOUS AMOUNTS OF WATER FOR 15 MINUTES THEN SEE PHYSICIAN AT ONCE.
SKIN-FLUSH WITH WATER AND WASH WITH SOAP AND WATER. INGESTION-NOT
APPLICAB LE

Fire Fighting

Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS WHEN A LARGE NUMBER OF CELLS ARE INVOLVED.
Unusual Fire/Explosion Hazard:CELL CAN RUPTURE WHEN SUBJECTED TO HIGH
TEMPERATURES.

Accidental Release

Spill Release Procedures:USE GENERAL CLEANUP PROCEDURES. USE RUBBER
GLOVES FOR CLEANING OF SPILLS OR HANDLING INTERNAL PARTS OF CELLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE CELLS IN DRY PLACE.
Other Precautions:AVOID SKIN AND EYE CONTACT. DO NOT INHALE VAPORS.
COLLECT ALL RELEASED MATERIAL IN A PLASTIC BAG FOR WASTE DISPOSAL.

Exposure Controls

Supplemental Safety and Health
ENGINEERING CONTROLS: NOT REQUIRED FOR NORMAL USE.

Chemical Properties

HCC:Z7
Appearance and Odor:CLEAR LIQUID (KOH), GREY POWDER (ZINC), BLACK
POWDER (MNO2).

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.