CCTCL - FLOW-MATE, 0600

  • MSDS: CCTCL
  • Manufacturer: CERTIFIED LABS
  • Product Name: FLOW-MATE, 0600
  • National Stock Number: 8030-00N061202
Product Identification

Product ID:FLOW-MATE, 0600
MSDS Date:03/14/1995
FSC:8030
NIIN:00N061202
MSDS Number: CCTCL

Responsible Party
CERTIFIED LABS
IRVING, TX 75015
US

Emergency Phone: 214-438-1381

Info Phone: 214-438-1381

Preparer: B SANFORD

Cage: 0A649

Contractor
CERTIFIED LABS DIV OF NCH CORP
152170 IRVING, TX 75015 US

Telephone: 214-438-1381972-438-1381

Cage: 53417

Ingredients

GLYCOLS, POLYETHYLENE MONO(TRIMETHYLNONYL);

CAS: 60828-78-6

RTECS: MD0907900

OSHA PEL N/K

ACGIH TLV: N/K


PARAMENTHADIENE; (TERPENE HYDROCARBONS)

CAS: 68956-56-9

OSHA PEL N/K

ACGIH TLV: N/K


ACETALDEHYDE (SARA 313) (CERCLA)

CAS: 75-07-0

RTECS: AB1925000

Fraction By Weight: <0.1%

OSHA PEL 200 PPM

ACGIH TLV: C 25PPM, A3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


P-DIOXANE; (DIOXANE)

CAS: 123-91-1

RTECS: JG8225000

Fraction By Weight: <0.1%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ETHYLENE OXIDE (SARA 302/313) (CERCLA)

CAS: 75-21-8

RTECS: KX2450000

Fraction By Weight: <0.1%

OSHA PEL 1 PPM; SEE 1910.1047

ACGIH TLV: 1 PPM, A2

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


FORMALDEHYDE (SARA 302/313) (CERCLA)

CAS: 50-00-0

RTECS: LP8925000

Fraction By Weight: <0.1%

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM, A2

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


AGAIN. GET IMMED MED ATTN IF DISCOMFORT OCCURS.

RTECS: 9999999ZZ


TREAT PATIENT SYMPTOMATICALLY. INGEST & SUBSEQUENT

RTECS: 9999999ZZ


INTO THE LUNGS WHICH CAN CAUSE DAMAGE AND MAY BE

RTECS: 9999999ZZ


PREVENT PRODUCT FROM CONTAMINATING SOIL OR

RTECS: 9999999ZZ


TRACES OF FREE ETHYLENE OXIDES MAY BE PRESENT IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: IRRIT. MAY CAUSE ITCH,
REDNESS, PAIN, SWELL, EXCESS TEAR PRODUCTION & BLINKING. CORNEAL
INJURY & PERM VISUAL IMPAIRMENT IS POSS W/LONG TERM EXPOS. SKIN:
MAY CAUSE IRRIT, ITCH, REDNESS & SW ELL. RPTD/PRLNG EXPOS MAY LEAD
TO DERM.INHAL: LGE AMTS OF VAPS/MIST MAY CAUSE IRRIT TO RESP TRACT
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: W/COUGHING, SNEEZING & NAUS.
PRLNG/RPTD INHAL MAY RSLT IN LUNG INJURY. INGEST: GI IRRIT W/POSS
NAUS, VOMIT, DIARR, THIRST, FAINTNESS, DIZZ, WEAK & DROW. MAY ALSO
CAUSE STINGING/BURNING SENSA TION IN MOUTH & THROAT, SWELL, FORM OF
LESIONS & CHEST PAIN. INGEST & SUBSEQUENT VOMIT OF THIS PROD CAN
LEAD (SUP DAT)
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY AND SKIN
CONDITIONS SUCH AS ASTHMA, EMPHYSEMA, AND DERMATITIS.

First Aid

First Aid:INHAL: REMOVE FROM AREA TO FRESH AIR. SEEK MED ATTN IF RESP
IRRIT DEVELOPS/IF BRTHG BECOMES DFCLT. EYE: IMMED RINSE W/WATER.
REMOVE ANY CONT LENSES & CONTINUE FLUSHING FOR AT LEAST 15 MIN.
HOLD EYELID S APART TO ENSURE RINSING OF ENTIRE SURF OF EYES & LIDS
W/WATER. GET IMMED MED ATTN. SKIN: WASH AFFECTED AREAS W/PLENTY OF
SOAP & WATER FOR SEVERAL MIN. REMOVE & CLEAN CONTAM CLTHG & SHOES.
(SUP DAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:109F,43C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL FIRE-EXPOSED CONTRS W/WATER SPRAY TO PVNT
BURSTING. SPILLED MATERIAL MAY BE SLIPPERY.
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL TO DIST
SOURCES OF IGNIT & FLASHBACK. PROD MAY PRDCE FLOATING FIRE HAZ AS
LIQ FLOATS ON WATER. DO NOT SPRAY DIRECT STREAM(SUP DAT)

Accidental Release

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. DIKE &
CONTAIN SPILL IF SAFE TO DO SO. USE ONLY NON-SPARKING EQUIPMENT.
ABSORB W/INERT MATL & TRANSFER INTO PROPERLY LABELED CONTR FOR
DISPOSAL. WEAR APPROP PROT CLT HG. USE CARE AS SPILLS MAY BE
SLIPPERY.(ING 10)
Neutralizing Agent:NONE KNOWN.

Handling

Handling and Storage Precautions:STORE BETWEEN 35F AND 100F. USE WITH
CAUTION AROUND HEAT, SPARKS, PILOT LIGHTS, STATIC ELECTRICITY AND
OPEN FLAME.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, SOLDER, DRILL,
GRIND/EXPOSE EMPTY CONTRS TO HEAT, HOT SURF, SPKS/OPEN FLAMES.
ALWAYS STORE MATL IN ITS ORIGINAL CONTR. KEEP OUT OF REACH OF
CHILDREN. READ ENTIRE LABEL BE FORE USING PROD. (ING 11)

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS OF USE. A
NIOSH APPROVED RESPIRATOR IN POORLY VENTILATED AREAS AND/OR FOR
EXPOSURE ABOVE THE ACGIH TLV OR OSHA PEL OR WHERE MISTING EXISTS.
Ventilation:GEN MECHANICAL VENT IS NORM ADEQ. LOCAL VENT IS RECOMMENDED
TO CTL EXPOS FROM OPERATIONS THAT CAN GENERATE MISTS/VAPS.
Protective Gloves:POLYVINYL ALCOHOL.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . WEAR GENERAL DUTY WORK CLOTHING AND SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH:8.2 @ 10%. EXPLO HAZ:OF WATER INTO PROD. EFTS OF OVEREXP:TO ASPIR OF
PROD INTO LUNGS WHICH CAN CAUSE DMG & MAY BE FATAL. TARGET
ORGANS:EYES. CHRONIC:NO CHRONIC EFTS KNOWN. FIRST AID PROC:SEEK MED
A TTN IF IRRIT DEVELOPS. INGEST:GIVE 3-4 GLASSES OF WATER, BUT DO
NOT INDUCE VOMIT. IF VOMIT OCCURS, GIVE FLUIDS (ING 7)

Chemical Properties

Boiling Pt:B.P. Text:330F,166C
Vapor Pres:1.38
Vapor Density:4.9
Spec Gravity:0.845 (H*2O=1)
pH:SUPDAT
Evaporation Rate & Reference:0.165 (BUTYL ACETATE=1)
Solubility in Water:SLIGHT
Appearance and Odor:RED/ORANGE TRANSPARENT, MENTHOL/CITRUS ODOR
Percent Volatiles by Volume:96

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZERS, ALKALIES AND REDUCING AGENTS.
Stability Condition to Avoid:AVOID HEAT, HOT SURFACES, SPARKS AND OPEN
FLAMES.
Hazardous Decomposition Products:OXIDES OF CARBON, SMOKE AND FUMES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.