CCWTH - STP-460K

Product Identification

Product ID:STP-460K
MSDS Date:12/23/1994
FSC:6810
NIIN:00N075680
MSDS Number: CCWTH

Responsible Party
CALIFORNIA CARBON CO INC
2825 EAST GRANT ST
WILMINGTON, CA 90744
US

Emergency Phone: 213-775-6678

Info Phone: 310-436-1962

Cage: 2Z246

Contractor
CALIFORNIA CARBON CO INC
WILMINGTON, CA 90744-4033 US

Telephone: 562-436-1962

Cage: 2Z246

Ingredients

POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: <20%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACTIVATED CARBON (ACTIVATED CARBONS THAT HAVE ABSORBED

CAS: 7440-44-0

RTECS: FF5250000

OSHA PEL N/K

ACGIH TLV: N/K


THE IGNITION POINT AND MUST BE LABORATORY CHECKED FOR

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:AVOID EXPOSURE TO DUST LEVELS ABOVE 15
MG PER CUBIC METER. OVEREXPOSURE EFTS:TEMPORARY DRYNESS TO MUCOUS
MEMBRANE CAUSING COUGHING AND MINOR NOSE AND THROAT IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGESTION:CALL MD IMMEDIATELY . (PURE POSTASSIUM HYDROXIDE):
EYES:IRRIGATE EYES WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. SKIN:IRRIGATE SKIN WITH COPIOUS AMOUNTS OF WATER.
INHALATIO N:FOR INHALED DUST, MONITOR BREATHING AND ADMINISTER
ARTIFICIAL RESPIRATION OR OXYGEN. TRANSPORT TO HOSPITAL IF
REQUIRED.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NOT RATED BY THE NFPA-WATER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . SINCE WET ACTIVATED CARBON ABSORBS OXYGEN, DO NOT ENTER
CLOSED VESSEL WITHOUT SCBA.
Unusual Fire/Explosion Hazard:NEW KOH IMPREGNATED CARBON MAY REACT
EXOTHERMICALLY IF EXPOSED TO AIR UNDER STATIC CNDTNS. WHEN KOH
CARBON IS LOADED INTO A VESSEL, DESIGN AIR FLOW (SUPP DATA)

Accidental Release

Spill Release Procedures:COLLECT WITH BROOM AND SHOVEL. WEAR A NIOSH
APPROVED PARTICLE MASK, GOGGLES AND GLOVES. IF MEDIA BECOMES WET,
STORE FOR WASTE DISPOSAL IN PLASTIC LINED CONTAINERS. DO NOT ENTER
LARGE VESSELS W/OUT A N IOSH APPROVED SCBA-ESPECIALLY WHEN CARBON
IS WET.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:IN SEALED METAL DRUMS ONLY. PACKAGING
IN BOXES OR SLING BAGS REQUIRE IMMEDIATE USESAGE INTO AIR
PURIFICATION DEVICE WITH AIR MOVEMENT ACROSS MEDIA.
Other Precautions:PACKAGED ACTIVATED CARBON IS NOT RESISTANT TO
WEATHER/OUTSIDE STOR & REQS INDOOR TYPE I & TYPE II STOR
FACILITIES. CHECK OXYG CONTENT OF ATM OF ANY VESSEL CNTNING
ACTIVATED CARBON BEFORE ALLOWING ENTR Y OF PERS. STORE AWAY FROM
VOLAT(SUPDAT)

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . RESPIRATORY CLASSIFICATION TABLE G-2 PART
1910.93 (OSHA) RULES AND REGULATIONS. WHILE HANDLING, USE A NIOSH
APPROVED PARTICLE MASK.
Ventilation:LOCAL EXHAUST:VACUUM TO CONTROL DUST.
Protective Gloves:CORROSIVE CHEMICAL RESISTANT.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O:PURE KOH 0.9 PARTS TO 1 PART WATER. EXPLO HAZS:SHOULD BE
STARTED AND NOT INTERRUPTED. IF "HOT SPOTS" ARE PRESENT, RAPID
OXIDATION CAN BE STOPPED BY RESUMPTION OF AIR FLOW OR WATER SPRAY.
O THER PRECS:ORGANIC SOLVENTS AND MOISTURE (TO PRESERVE MEDIA).

Chemical Properties

Spec Gravity:1.8-2.1(H*2O=1)
Solubility in Water:SUPP DATA
Appearance and Odor:ODORLESS, BLACK CYLINDRICAL SOLID, FREE FLOWING
WHEN DRY.

Stability

Stability Indicator/Materials to Avoid:YES
LIQUID OR HIGHLY CONCENTRATED GASEOUS CHLORINE DIOXIDE; POTASSIUM
PAROXODISULPHATE, PEROXIDSED TETRAHYDROFURAN.
Stability Condition to Avoid:CLOSE PROXIMITY TO VOLATILE SOLVENTS; OPEN
FLAMES; STRONG OXIDIZING OR REDUCING CHEMICALS.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . (PURE POTASSIUM HYDROXIDE):WASH SPILL SITE WITH
COPIOUS AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.