CDFTV - MN 908 ALKALINE MANGANESE DIOXIDE CELL
- MSDS: CDFTV
- Manufacturer: DURACELL INC
- Product Name: MN 908 ALKALINE MANGANESE DIOXIDE CELL
- National Stock Number: 6135-00F041643
Product Identification
Product ID:MN 908 ALKALINE MANGANESE DIOXIDE CELL
MSDS Date:01/17/1994
FSC:6135
NIIN:00F041643
MSDS Number: CDFTV
Responsible Party
BETHEL, CT 06801-5000
US
Emergency Phone: 203-796-4292/617-449-7600
Info Phone: 203-796-4292/617-449-7600
Cage: GO384
Contractor
Telephone: 203-796-4000
Cage: 90303
Ingredients
PAPER, SILICA GEL
Fraction By Weight: 100%
MERCURY, QUICKSILVER (IARC CARCINOGEN GROUP 3) *96-4*
CAS: 7439-97-6
RTECS: OV4550000
OSHA PEL 0.05 MG/CUM
ACGIH TLV: 0.01 MG/CUM (SKIN)
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
PLASTIC
Fraction By Weight: 4%
POTASSIUM HYDROXIDE
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 85%
OSHA PEL 2 MG/CUM (CEILING)
ACGIH TLV: 2 MG/CUM (CEILING)
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
MANGANESE DIOXIDE, MANGANESE PEROXIDE *96-4*
CAS: 1313-13-9
RTECS: OP0350000
Fraction By Weight: 37%
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
ZINC
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 15%
OSHA PEL 15 MG/CUM
ACGIH TLV: 10 MG/CUM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 11%
CARBON, ACTIVATED CARBON, GRAPHITE
CAS: 7440-44-0
RTECS: FF5250100
Fraction By Weight: 4%
OSHA PEL 3.5 MG/CUM
ACGIH TLV: 3.5 MG/CUM
STEEL
Fraction By Weight: 18%
OSHA PEL 10 MG/CUM
ACGIH TLV: 10 MG/CUM
BRASS
Fraction By Weight: 2%
OSHA PEL 10 MG/CUM
ACGIH TLV: 10 MG/CUM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THESE CHEMICALS ARE CONTAINED IN A
SEALED CAN. RISK OF EXPOSURE OCCURS ONLY IF BATTERY IS
MECHANICALLY, PHYSICALLY/ELECTRICALLY ABUSED. SKIN & EYE CONTACT
W/POTASSIUM HYDROXIDE MAY CAUSE CHEMICAL BURN S & PERMANENT EYE
INJURY.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:CHEMICAL BURNS.
First Aid
First Aid:SKIN/EYES: IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR
15 MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Fire Fighting Procedures:WEAR SCBA WHEN A LARGE NUMBER OF CELLS ARE
INVOLVED IN A FIRE.
Unusual Fire/Explosion Hazard:CELLS MAY RELEASE TOXIC ZINC FUMES WHEN
EXPOSED TO FIRE.
Accidental Release
Spill Release Procedures:AVOID SKIN & EYE CONTACT.
Handling
Handling and Storage Precautions:STORE AT ROOM TEMP. AVOID SKIN & EYE
CONTACT. DON'T ATTEMPT TO RECHARGE. INSTALL CELLS IAW/EQUIPMENT
INSTRUCTIONS. DON'T DISPOSE OF IN FIRE.
Other Precautions:REPLACE ALL BATTERIES IN EQUIPMENT AT SAME TIME.
DON'T MIX BATTERY SYSTEMS SUCH AS ALKALINE & ZINC CARBON IN SAME
EQUIPMENT. DON'T CARRY BATTERIES LOOSE IN POCKET/BAG.
Exposure Controls
Respiratory Protection:SCBA WHEN LARGE NUMBERS OF CELLS ARE INVOLVED IN
A FIRE.
Ventilation:SUBSEQUENT TO FIRE, PROVIDE AS MUCH VENTILATION AS
POSSIBLE.
Protective Gloves:NEOPRENE, RUBBER/LATEX-NITRILE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Supplemental Safety and Health
MSDS INFORMATION IS FOR MANGANESE DIOXIDE.
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:995F
Spec Gravity:5
Solubility in Water:0%
Appearance and Odor:BLACK POWDER
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, DISASSEMBLY, RECHARGE,
MECHANICAL/PHYSICAL/ELECTRICAL ABUSE, HIGH TEMPS, FIRE.
Hazardous Decomposition Products:WHEN HEATED: HAZARDOUS FUMES OF ZINC &
CAUSTIC POTASSIUM HYDROXIDE.
Disposal
Waste Disposal Methods:SMALL QUANTITIES: DISPOSE OF W/HOUSEHOLD TRASH.
LARGE QUANTITIES: TREAT AS IF A HAZARDOUS WASTE. DON'T INCINERATE
SINCE CELLS MAY EXPLODE AT EXCESSIVE TEMPS. DISPOSE OF IAW/FEDERAL,
STATE & LOCAL REGU LATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.