CDGBS - NAPA 4070 FAMILY SPIN ON COOLANT CONDITIONER
- MSDS: CDGBS
- Manufacturer: PERRY FILTERS INC
- Product Name: NAPA 4070 FAMILY SPIN ON COOLANT CONDITIONER
- National Stock Number: 6850-01-387-1529
Product Identification
Product ID:NAPA 4070 FAMILY SPIN ON COOLANT CONDITIONER
MSDS Date:05/15/1986
FSC:6850
NIIN:01-387-1529
MSDS Number: CDGBS
Responsible Party
OKLAHOMA CITY, OK 73143
US
Emergency Phone: 405-672-2311
Info Phone: 405-672-2311
Cage: 59549
Contractor
Telephone: 405-672-2311
Cage: 59549
Ingredients
SODIUM TETRABORATE PENTAHYDRATE
Fraction By Weight: 39%
SODIUM NITRITE (CERCLA)
CAS: 7632-00-0
RTECS: RA1225000
Fraction By Weight: 13.4%
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
SODIUM NITRATE
CAS: 7631-99-4
RTECS: WC5600000
Fraction By Weight: 23.5%
2-MERCAPTOBENZOTHIAZOLE
CAS: 149-30-4
RTECS: DL6475000
Fraction By Weight: 7.1%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CAN CAUSE FLUSHED FACE, UNEVEN
HEART ACTION, TRMORS, DIZZINESS. INGESTION OF LARGE AMOUNT MAY
CAUSE SYSTEMATIC EFFECTS AND DEATH. CHRONIC: MAY CAUSE ALLERGIC
SKIN REACTION IN SOME INDIVIDUALS A ND POSSIBLE YELLOWING OF SKIN.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:FLUSHED FACE, UNEVEN HEART ACTION, TREMORS,
DIZZINESS, SYSTEMIC EFFECTS, DEATH, YELLOWING OF SKIN, ALLERGIC
REACTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES-FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL ATTENTION
IF IRRITATION DEVELOPS. SKIN-REMOVE CONTAMINATED CLOTHES. FLUSH
WITH WATER THEN WASH WITH MILD SOAP & WATER. INGESTED-IF CONSCIOUS,
DRINK PL ENTY OF WATER. CONTACT PHYSICIAN IMMEDIATELY. AVOID
ALCOHOLIC DRINKS.
Fire Fighting
Extinguishing Media:WATER FOG, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:KEEP UPWIND OF FIRE. WEAR SELF-CONTAINED
BREATHING APPARATUS AND FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE
WATER TO COOL FIRE EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:OXIDIZER! DO NOT STORE NEAR FUELS.
EXPLODES WHEN HEATED OVER 1000F OR MIXED WITH CYANIDES. WILL IGNITE
ON FRICTION WHEN CONTAMINATED WITH ORGANIC MATTER.
Accidental Release
Spill Release Procedures:KEEP SPILLED MATERIAL AWAY FROM COMBUSTIBLES.
STOP LEAK IF W/O RISK. COLLECT SPILLED MATERIAL INTO A CLEAN, DRY
METAL CONTAINER. ADD WATER & TIGHTLY COVER. USE AS SOON AS
POSSIBLE. USE NONCOMBUSTIBLE LIQUID SPILLS. SHOVEL INTO CLEAN
METAL CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM
COMBUSTIBLE MATERIALS AND ACIDS. KEEP CONTAINER CLOSED WHEN NOT IN
USE. DO NOT INHALE DUSTS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29 CFR
1910.134.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:RUBBER APRON, LONG-SLEEVED SHIRT AND
TROUSERS. FOR PROLONGED CONTACT-IMPERVIOUS CLOTHES. DLA-HMIS:EYE
WASH/SAFETY SHOWER
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
MSDS AS RECEIVED WAS WRITTEN FOR BRIQUETTES. DLA-HMIS BEST GUESS IS
THAT THE BRIQUETTES ARE USED TO MAKE UP THE LIQUID FOUND IN THE
PINT BOTTLES THAT MAKE UP THIS NSN.
Chemical Properties
HCC:D1
Spec Gravity:1.03
Solubility in Water:COMPLETE
Appearance and Odor:TAN & PURPLE BRIQUETTE; MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS.
Stability Condition to Avoid:EXTREME HEAT, FLAMMABLES, FLAME,
INCOMPATIBLE MATERIALS.
Hazardous Decomposition Products:TOXIC OXIDES OF NITROGEN, SULFUR AND
CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:RCRA IGNITABLE WASTE. INCINERATE IN ACCORDANCE
WITH LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.