CDLVL - AV-2012;402037
- MSDS: CDLVL
- Manufacturer: SAFT AMERICA INC POWER SOURCES DIV
- Product Name: AV-2012;402037
- National Stock Number: 6140-01-055-9627
Product Identification
Product ID:AV-2012;402037
MSDS Date:02/28/1991
FSC:6140
NIIN:01-055-9627
MSDS Number: CDLVL
Responsible Party
VALDOSTA, GA 31603
US
Emergency Phone: 912-247-2331
Info Phone: 912-247-2331
Preparer: (ILLEGIBLE)
Cage: 09052
Contractor
Telephone: 912-247-2331
Cage: 09052
Ingredients
CADMIUM (SARA 313) (CERCLA) [CONSISTING OF CADMIUM,CADMIUM
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 8-20%
OSHA PEL 0.2 MG/M3 DUST; Z-2
ACGIH TLV: 0.01 MG/M3 DUST;9596
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
NICKEL (SARA 313) (CERCLA) [CONSISTING OF NICKEL,NICKEL
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 15-35%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9596
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:**ARTICLE** LEAKAGE FROM THIS BATTERY
MAY BE TOXIC AND CORROSIVE.
Explanation of Carcinogenicity:CONTAINS CADMIUM AND NICKEL WHICH ARE
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:IRRITATION OF THE NOSEAND
THROAT,SWEATING,CHILSS,SHORTNESS OF BREATH,WEAKNESS,LOCAL
DERMATITIS,NAUSEA,COUGHING,CHEST PAIN.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING
RESPIRATORY,PROSTATE,LIVER OR KIDNEY AILMENTS MAY BE AT INCREASED
RISK FROM EXPOSURE.
First Aid
First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH WATER.GET MEDICAL
ATTENTION IF NEEDED.EYES:FLUSH WITH WATER FOR 15 MINUTES.GET
IMMEDIATE MEDICAL ATTENTION.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN
OR ARTIFICI AL RESPIRATION IF NEEDED.GET IMMEDIATE MEDICAL
ATTENTION.INGEST:GET PROMPT QUALIFIED MEDICAL ATTENTION.IF
CONSCIOUS,INDUCE VOMITING UNDER MEDICAL SUPERVISION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:WATER,DRY CHEMICAL,CARBON DIOXIDE.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:CONTAIN SPILL;COLLECT IN A PLASTIC-LINED
CONTAINER.HEPA VACUUMING IS PREFERRED.FLUSH SPILL AREA WITH WATER.
Neutralizing Agent:NOT REPORTED.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
PLACE.KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:AVOID CONTACT WITH CLOTHING.AVOID GENERATING DUST.
Exposure Controls
Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A NIOSH/MSHA APPROVED RESPIRATOR FOR DUST.
Ventilation:NOSPECIAL REQUIREMENTS SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES OR GOGGLES.
Other Protective Equipment:PROVIDE A LOCAL EYE WASH STATION AND SAFETY
SHOWER.
Work Hygienic Practices:USE REASONABLE CARE IN HANDLING THIS
PRODUCT.WASH HANDS AFTER USE AND BEFORE EATING.
Supplemental Safety and Health
HMIS-LEVIEN SPOKE WITH TIM AT SAFT.WE LEARNED THAT THIS BATTERY IS A
DRY TYPE,NON-HAZARDOUS,AND NOT REGULATED FOR TRANSPORT.
Chemical Properties
HCC:N1
Spec Gravity:1.6
Solubility in Water:INSOLUBLE
Appearance and Odor:6 VOLT NI-CAD BATTERY.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:USE HAZMAT STORAGE.
Hazardous Decomposition Products:METAL OXIDE FUMES.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.THIS ITEM IS CONSIDERED RCRA HAZARDOUS
WASTE(D019)[FP-D].
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.