CDQJL - 864 1128 KODAK K-LAB YELLOW, DEVELOPER, PROCESS K-14M, SOLN
- MSDS: CDQJL
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 864 1128 KODAK K-LAB YELLOW, DEVELOPER, PROCESS K-14M, SOLN
- National Stock Number: 6750-00D006400
Product Identification
Product ID:864 1128 KODAK K-LAB YELLOW, DEVELOPER, PROCESS K-14M, SOLN
MSDS Date:09/20/1996
FSC:6750
NIIN:00D006400
Kit Part:Y
MSDS Number: CDQJL
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 716-722-5151
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 95-100%
SODIUM SULFATE DECAHYDRATE (GLAUBER'S SALT)
CAS: 7757-82-6
RTECS: WE1650000
Fraction By Weight: 1-5%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
HEXYLENE GLYCOL
CAS: 107-41-5
RTECS: SA0810000
Fraction By Weight: <1%
OSHA PEL C 25 PPM
ACGIH TLV: C 25 PPM; 9596
4-(N-ETHYL-N-2-HYDROXYETHYL)-2-METHYLPHENYLENEDIAMINE
Fraction By Weight: <1%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALE-EXPECTED TO BE A LOW HAZARD FOR
RECOMMENDED HANDLING. EYE-CAUSES IRRITATION. SKIN-CAUSES
IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. INGESTION-EXPECTED TO
BE A LOW INGESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALE-IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYE-IMMEDIATELY FLUSH WITH PLENTY OF
WATER FOR 15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY REMOVE
CONTAMINATED CLOTHING & SHOES & WASH WITH SOAP & WATER. GET
EMDICAL ATTENTION. INGEST-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL
ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSICOUS PERSON.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE AGENT APPROPIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT, THEN PALCE
IN A CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO
REMOVE RESIDUAL CONTAMINA TION.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
INCOMPATIBLE SUBSTANCES.
Other Precautions:AVOID CONTACT WITH EYES, SKIN AND CLOTHING. USE WITH
ADEQUATE VENTILATION. WASH THOROUGHLY AFTER HANDLING.NONE
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:WEAR IMPERVIOUS GLOVES
Eye Protection:SAFETY GLASSES WITH SIDE SHIELD
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:B3
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.03
pH:12.5
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS.
Percent Volatiles by Volume:95-100
Stability
Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MUST BE MADE IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.