CDWCV - AMMONIUM BIFLUORIDE
- MSDS: CDWCV
- Manufacturer: FISHER SCIENTIFIC
- Product Name: AMMONIUM BIFLUORIDE
- National Stock Number: 6810-00N001396
Product Identification
Product ID:AMMONIUM BIFLUORIDE
MSDS Date:09/29/1994
FSC:6810
NIIN:00N001396
MSDS Number: CDWCV
Responsible Party
FAIR LAWN, NJ 07410
US
Emergency Phone: 201-796-7100
Info Phone: 201-798-7100
Cage: 1B464
Contractor
Telephone: 201-796-7100
Cage: 1B464
Ingredients
PELVIS & SPINAL COLUMN MAY OCCUR. FOR MORE INFO
RTECS: 9999999ZZ
TREAT SYMPTOMATICALLY & SUPPORTIVELY. GET
RTECS: 9999999ZZ
LIFTING UPPER & LOWER LIDS, UNTIL NO EVIDENCE OF
RTECS: 9999999ZZ
W/NORM SALINE UNTIL PH HAS REDUCED TO NORM (30-60
RTECS: 9999999ZZ
GIVE LGE AMTS OF MILK/WATER IMMED. DO NOT
RTECS: 9999999ZZ
UNABLE TO SWALLOW. DO NOT PERFORM GASTRIC
RTECS: 9999999ZZ
HIPS TO HELP PVNT ASPIR. TREAT SYMPTOMATICALLY &
RTECS: 9999999ZZ
GIVE CALCIUM GLUCONATE, 10
RTECS: 9999999ZZ
SYMPS DISAPPEAR. IF SERUM MAGNESIUM IS REDUCED,
RTECS: 9999999ZZ
BE ADMINISTERED BY QUALIFIED MEDICAL PERSONNEL.
RTECS: 9999999ZZ
ISOLATE HAZARD AREA AND DENY ENTRY. REPORTABLE
RTECS: 9999999ZZ
AMMONIUM BIFLUORIDE (CERCLA)
CAS: 1341-49-7
RTECS: BQ9200000
Fraction By Weight: 100%
OSHA PEL 2.5 MG (F)/M3
ACGIH TLV: 2.5 MG (F)/M3
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
DISORDERS, INCL HYPOCALCEMIA,
RTECS: 9999999ZZ
INCL CONGESTION & HEMORRHAGIC INFILTRATION OF ALL
RTECS: 9999999ZZ
CASES, MALAISE & EPIGASTRIC PAIN MAY PERSIST FOR
RTECS: 9999999ZZ
MEMB. THERE MAY BE DISCOLORATION OF TISS. EFTS ON
RTECS: 9999999ZZ
EDEMA OF EPIGLOTTIS & SHOCK MAY OCCUR. CHRONIC
RTECS: 9999999ZZ
SORE THROAT, SINUS TROUBLE, ASTHMA, INFLAMM &
RTECS: 9999999ZZ
RPTD/PRLNG EXPOS TO DUSTS, FUMES/CORR
RTECS: 9999999ZZ
MAY CAUSE FLUOROSIS CHARACTERIZED BY
RTECS: 9999999ZZ
WEAK & GEN ILL HLTH. EXCESS CALCIFICATION OF BONES
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IN PRESENCE OF MOISTURE A CORR
SUBSTANCE MAY BE FORMED. INHAL: DUST MAY CAUSE IRRIT W/COUGHING &
SHORTNESS OF BRTH, NAUS, & LARYNGEAL & PULM EDEMA. MAY
CAUSE/AGGRAVATE ASTHMA. SYSTEMIC POISONIN G AS DETAILED IN ACUTE
INGEST MAY OCCUR. MAY CAUSE SEV IRRIT OF RESP TRACT W/COUGHING,
CHOKING, PAIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: & POSS BURNS OF MUC MEMB. SEV CASES
MAY BE FATAL. SKIN: MAY CAUSE IRRIT W/REDNESS, PAIN & POSS BURNS.
ABSORPTION MAY OCCUR THRU DAMAGED SKIN & RSLT IN SYSTEMIC
POISONING. EYE: DUSTS/SOLNS MA Y CAUSE IRRIT & POSS BURNS. INGEST:
SYMPS OF ACUTE FLUORIDE TOXICITY MAY BE CAUSED BY A VARIETY OF
METABOLIC (ING 2)
Medical Cond Aggravated by Exposure:PERSONS WITH ASTHMA.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR IMMED. PERFORM ARTF RESP IF NEC.
MAINTAIN AIRWAY, BLOOD PRESS & RESP. KEEP WARM & AT REST. TREAT
SYMPTOMATICALLY & SUPPORTIVELY. GET MED ATTN IMMED. SKIN: REMOVE
CONTAM CLTH G & SHOES IMMED. WASH W/SOAP & WATER UNTIL NO EVIDENCE
OF CHEM REMAINS (APPROX 15-20 MIN). IF BURNS OCCUR, COVER AFFECTED
AREA SECURELY W/STERILE, DRY, LOOSE-FITTING DRESSING. (ING 12)
Fire Fighting
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR
REGULAR FOAM. FOR LARGER FIRES, USE WATER SPRAY, FOG OR REGULAR
FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
MOVE CONTR FROM FIRE AREA IF W/OUT RISK. APPLY COOLING WATER TO
SIDES OF CONTRS EXPOSED TO FLAMES (SUP DAT)
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO
HEAT OR FLAME.
Accidental Release
Spill Release Procedures:DO NOT TOUCH MATL. STOP LEAK IF W/OUT RISK.
SML SPILL: TAKE UP W/ABSORB MATL & PLACE INTO CONTRS FOR LATER
DISP. SML DRY SPILL: W/CLEAN SHOVEL PLACE MATL INTO CLEAN, DRY
CONTR & COVER. LGE SPILL: DIKE FAR AHEAD OF SPILL FOR LATER DISP.
(ING 21)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE ALL FED, STATE & LOC REGS WHEN
STORING SUBSTANCE. STORE IN PLASTIC, RUB, WOOL/PARAFFINED CONTRS.
STORE AWAY FROM INCOMPATIBLE SUBSTANCES.
Other Precautions:DO NOT STORE IN GLASS/PORCELAIN CONTRS. STORE IN
COOL, DRY PLACE; KEEP CONTR TIGHTLY CLSD WHEN NOT IN USE. MAY BURN
BUT DOES NOT IGNITE READILY. FLAMM, POISONOUS GASES MAY ACCUM IN
TANKS & HOPPER CARS . MAY IGNITE COMBUST (WOOD, PAPER, OIL).
Exposure Controls
Respiratory Protection:THE SPECIFIC RESP SELECTED MUST BE BASED ON
CONTAM LEVELS FOUND IN WORK PLACE, MUST NOT EXCEED WORKING LIMS OF
RESP & BE NIOSH APPRVD. FOR COMPLETE LIST OF RESPIRATORS CONTACT
NEHC .
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION SYSTEM TO MEET PUBLISHED
EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
APPROP PROT CLTHG & EQUIP TO PVNT CONT W/SUBSTANCE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: UNTIL WELL AFTER FIRE IS OUT. STAY AWAY FROM ENDS OF
TANKS. DO NOT USE WATER DIRECTLY ON MATL. IF LGE AMTS OF COMBUST
MATLS INVOLVED, USE WATER SPRAY/FOG IN FLOODING AMTS TO ABSORB CO
RR VAPS. COOL CONTRS FROM AS FAR AS DIST AS POSS. KEEP UPWIND.
Chemical Properties
Boiling Pt:B.P. Text:463F,239C
Melt/Freeze Pt:M.P/F.P Text:>257F,>125C
Vapor Pres:NEGLIGIBLE
Spec Gravity:1.211-1.51
Solubility in Water:38-58%
Appearance and Odor:ODORLESS, WHITE, RHOMBIC OR TETRAGONAL,
DELIQUESCENT CRYSTALS OR FLAKES
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, STRONG BASES, CEMENT, GLASS, METALS, SILICEOUS MATERIALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY INCLUDE TOXIC AND CORROSIVE
AMMONIA, HYDROGEN FLUORIDE, AND TOXIC OXIDES OF NITROGEN.
Disposal
Waste Disposal Methods:OBSERVE ALL FEDERAL, STATE AND LOCAL REGULATIONS
WHEN DISPOSING OF THIS SUBSTANCE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their