CDZBR - 862 3274, KODAK EKTACOLOR PRIME DEVELOPER REGENERATOR (SOLN)
- MSDS: CDZBR
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 862 3274, KODAK EKTACOLOR PRIME DEVELOPER REGENERATOR (SOLN)
- National Stock Number: 6750-00D006095
Product Identification
Product ID:862 3274, KODAK EKTACOLOR PRIME DEVELOPER REGENERATOR (SOLN)
MSDS Date:08/02/1996
FSC:6750
NIIN:00D006095
Kit Part:Y
MSDS Number: CDZBR
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 95-100%
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 1-5%
ETHANOL, 2,2',2"-NITRILOTRI-; (TRIETHANOLAMINE)
CAS: 25646-71-3
RTECS: PB0431000
Fraction By Weight: <1%
ACGIH TLV: 5 MG/M3
DIETHYLHYDROXYLAMINE
CAS: 3710-84-7
RTECS: NC3500000
Fraction By Weight: <1%
Hazards
LD50 LC50 Mixture:TLV: TRIETHANOLAMINE: 5 MG/M3 TWA
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE A LOW
HAZARD FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN.
MAY CAUSE TRANSIENT IRRITATION. SKIN: MAY CAUSE IRRITATION. MAY
CAUSE ALLERGIC SKIN REACTION. INGESTIO N: EXPECTED TO BE A LOW
INGESTION HAZARD. MAY CAUSE IRRITATION OF THE GASTROINTESTINAL
TRACT.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHALATION-MOVE TO FRESH AIR. TREAT SYMPTOMATICALLY. GET
MEDICAL ATTENTION IF SYMPTOMS OCCUR. EYES-IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR AT LEAST 15 MIN. GET MEDICAL ATTENTION.
SKIN-IMMEDIATELY F LUSH WITH PLENTY OF WATER FOR 15 MIN WHILE
REMOVING CONTAMINATED CLOTHES. GET MEDCIAL ATTENTION.
INGESTED-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL ATTENTION. NEVER
GIVE ANYTHING BY MOUTH IF UNCONSCIOS
Fire Fighting
Flash Point:NONE.
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:SMALL: FLUSH TO SEWER WITH LARGE AMOUNTS OF
WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE IN A CONTAINER FOR CHEMICAL WASTE. CLEAN
SURFACE THOROUGHLY TO REMOVE RE SIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USE. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS.
Protective Gloves:IMPERVIOUS GLOVES FOR RISK OF EXPOSURE.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
WEAR PROTECTIVE CLOTHING APPROPIATE FOR THE RISK OF EXPOSURE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
THIS IS THE WORKING SOLUTION!
Chemical Properties
HCC:B3
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6 AIR=1
pH:10.8
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID. LIGHT YELLOW. MINTY ODOR.
Percent Volatiles by Volume:95-100
Stability
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.