CFCSY - CLASSIC,SUPER HEAVY DUTY,INDUSTRIAL,412
- MSDS: CFCSY
- Manufacturer: EVEREADY BATTERY CO INC
- Product Name: CLASSIC,SUPER HEAVY DUTY,INDUSTRIAL,412
- National Stock Number: 6135-00-643-3485
Product Identification
Product ID:CLASSIC,SUPER HEAVY DUTY,INDUSTRIAL,412
MSDS Date:07/02/1996
FSC:6135
NIIN:00-643-3485
MSDS Number: CFCSY
Responsible Party
WESTLAKE, OH 44145-2536
US
Emergency Phone: 216-835-7368
Info Phone: 216-835-7368
Cage: 66571
Contractor
Telephone: 216-835-7368
Cage: 83740
Ingredients
CARBON BLACK/ACETYLENE BLACK
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: 3 - 7%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3; 9596
AMMONIUM CHLORIDE (CERCLA)
CAS: 12125-02-9
RTECS: BP4550000
Fraction By Weight: 0 - 10%
OSHA PEL 10 MG/M3
ACGIH TLV: 10 MG/M3 FUME; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
Fraction By Weight: 15 - 31%
OSHA PEL 5 MG MN/M3 CEILING
ACGIH TLV: 5 MG MN/M3
ZINC (SARA 313) (CERCLA)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 7 - 42%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC CHLORIDE (SARA 313) (CERCLA)
CAS: 7646-85-7
RTECS: ZH1400000
Fraction By Weight: 2 - 10%
OSHA PEL 1 MG/M3
ACGIH TLV: 1MG/M3/2STEL(FUME)96
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NOT RELEVENT
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS OF USE, THE
BATTERY IS HERMETICALLY SEALED. IF BROKEN OR IN FIRE: TARGET
ORGANS:EYES, SKIN, RESPIRATORY AND GI TRACTS. ACUTE- INGESTION CAN
BE HARMFUL. CONTENTS OF AN OPEN BATT ERY CAN CAUSE SERIOUS CHEMICAL
BURNS OFGI TRACT, EYES, SKIN AND RESPIRATORY TRACT. CHRONIC-
UNKNOWN.
Explanation of Carcinogenicity:ACETYLENE BLACK IS LISTED AS A POSSIBLE
CARCINOGEN BY INTERNATIONA AGENCY FOR RESEARCH ON CANCER (IARC) PER
MSDS.
Effects of Overexposure:NONE IF BATTERY IS NOT BROKEN OR IN FIRE. IF
BURNED OR LEAKING: SEVERE IRRITATION, CHEMICAL BURNS, PAIN, NAUSEA,
VOMITING, DIARRHEA, DIZZINESS, UNCONSCIOUSNESS, ALLERGIC PULMONARY
ASTHMA
Medical Cond Aggravated by Exposure:NOT RELEVANT
First Aid
First Aid:IF INGESTED, DO NOT INDUCE VOMITING NOR GIVE FOOD/DRINK. SEEK
MEDICAL ATTENTION IMMEDIATELY. CALL NATIONAL BATTERY INGESTION
HOTLINE FOR ADVICE (202-625-3333) COLLECT DAY/NIGHT. IF INHALED,
PROVIDE FR ESH AIR & CALL A DOCTOR. IF SKIN IS CONTAMINATED, REMOVE
CLOTHING & WASH SKIN WITH SOAP & WATER. IF IRRITATION PERSISTS, SEE
DOCTOR. FOR EYE, FLUSH IMMEDIATELY WITH WATER FOR 15 MINUTES. SEE
DOCTOR.
Fire Fighting
Flash Point:NOT RELEVANT
Lower Limits:NOT RELEVANT
Upper Limits:NOT RELEVANT
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, FOAM OR DRY CHEMICAL
FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS. COOL EXTERIOR OF BATTERIES IF
EXPOSED TO FIRE TO PREVENT RUPTURE.
Unusual Fire/Explosion Hazard:BATTERIES MAY RUPTURE.
Accidental Release
Spill Release Procedures:IF BROKEN, COLLECT AND TRANSFER TO PROPER
CONTAINER FOR DISPOSAL. WEAR GLOVES.
Neutralizing Agent:NOT RELEVANT
Handling
Handling and Storage Precautions:STORE IN COOL, VENTILATED AREA.
ELEVATED TEMPERATURES CAN RESULT IN SHORTENED BATTERY LIFE. KEEP
OUT OF REACH OF SMALL CHILDREN.
Other Precautions:DO NOT DISPOSE OF IN FIRE, PUT IN BACKWARDS, MIX WITH
USED/OTHER TYPE. DO NOT TOUCH BROKEN/LEAKING BATTERIES. AVOID
MECHANICAL/ELECTRICAL ABUSE. DO NOT ATTEMPT TO RECHARGE. AVOID
SHORT CIRCUITS. DO NO T CARRY BATTERIES LOOSE IN POCKET.
Exposure Controls
Respiratory Protection:NOT NECESSARY UNDER NORMAL CONDITIONS.
Ventilation:NOT NECESSARY UNDER NORMAL CONDITIONS.
Protective Gloves:NATURAL RUBBER IF HANDLING LEAKERS
Eye Protection:SAFETY GLASSES+SIDE SHIELDS FOR LEAKERS
Other Protective Equipment:NOT NECESSARY UNDER NORMAL CONDITIONS.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES.
Supplemental Safety and Health
THE MANUFACTURER STATES THIS BATTERY IS AN ARTICLE AND, AS SUCH, IS NOT
SUBJECT TO OSHA HAZARD COMMUNICATION STANDARD REQUIREMENT FOR
PREPARATION OF A MATERIAL SAFETY DATA SHEET. AS AN ARTICLE, THIS B
ATTERY AND ITS CONTENTS ARE NOT SUBJECTTO THE REQUIREMENTS OF THE
EMERGENCY PLANNING AND COMUNITY RIGHT-TO-KNOW ACT.
Chemical Properties
HCC:Z7
NRC/State Lic Num:NOT RELEVANT
Decomp Temp:Decomp Text:NOT KNOWN
Spec Gravity:NOT RELEVANT
Viscosity:NOT RELEVANT
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:NOT RELEVANT
Appearance and Odor:BATTERY/ARTICLE - ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
NOT KNOWN
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:NOT KNOWN
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. RECYCLING RECOMMENDED. CALL 1-800-8-BATTERY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.