CFCWG - LEAD ACID BATTERY
- MSDS: CFCWG
- Manufacturer: EXIDE CORP
- Product Name: LEAD ACID BATTERY
- National Stock Number: 6140-01-263-7799
Product Identification
Product ID:LEAD ACID BATTERY
MSDS Date:02/01/1996
FSC:6140
NIIN:01-263-7799
MSDS Number: CFCWG
Responsible Party
READING (FORMALLY IN HORSHAM), PA 19612-4205
US
Emergency Phone: 610-378-0500/800-424-9300(CHEMTREC)
Info Phone: 610-378-0550/ FAX -0616
Preparer: ENV. RESOURCES DEPT.
Cage: 20038
Contractor
Telephone: 610-378-0500/0798
Cage: NO672
Ingredients
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 53%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.15 MG/M3;DUST 9394
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA III)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: 0.2%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9394
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA 313) (CERCLA)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: 0.003%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.01 MG/M3, A1; 9495
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
CALCIUM, METAL
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: 0.02%
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 0.06%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9394
SULFURIC ACID (SARA III)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 30-40%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9394
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
INGREDIENTS 8-9 COMPRISE THE CASE MATERIAL
POLYPROPYLENE
CAS: 9003-07-0
RTECS: TR5000000
Fraction By Weight: 5-6%
RUBBER, HARD
OTHER COMPONENTS, INGREDIENT 11
SILICA, CRYSTALLINE - FUSED (GEL CELL BATTERIES ONLY)
CAS: 60676-86-0
RTECS: VV7328000
Fraction By Weight: 3-5%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.1 MG/M3 RDUST;9394
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE-ELECTROLYTE:SEVERE SKIN
IRRITATION, DAMAGE TO CORNEA MAY CAUSE BLINDNESS, UPPER
RESPIRATORY. LEAD:HEADACHE, FATIGUE, ABDOMINAL PAIN, LOST APPETITE,
MUSCLE ACHES. CHRONIC-ELECTROLYTE:POSSIBLE ERO SION OF TOOTH
ENAMEL; INFLAMMATION OF NOSE, THROAT, BRONCHIAL TUBES. LEAD:ANEMIA,
NEUROPATHY. KIDNEY DAMAGE, REPRODUCTO
Explanation of Carcinogenicity:CONTAINS INORGANIC ACID, LEAD, ARSENIC.
SEE THE INDIVIDUAL IARC & NTP REPORTS FOR DETAILS OF
CARCINOGENICITY.
Effects of Overexposure:ELECTROLYTE:SEVERE SKIN IRRITATION, DAMAGE TO
CORNEA. SEVERE UPPER RESPIRATORY IRRITATION. LEAD:HEADACHE,
FATIGUE, ABDOMINAL PAIN, LOST APPETITE, MUSCLE ACHES.
Medical Cond Aggravated by Exposure:OVEREXPOSURE TO SULFURIC ACID MIST
MAY CAUSE LUNG DAMAGE & AGGRAVATE PULMONARY CONDITIONS. CONTACT OF
SULFURIC ACID W/SKIN MAY AGGRIVATE SKIN DISEASES SUCH AS ECZEMA &
CONTACT DERMATITIS.
First Aid
First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
EYE:FLUSH W/WATER FOR 15 MIN. SKIN:WASH W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. INHALED:REMOVE FROM
EXPOSURE. A ID OR RESTORE BREATHING AS NEEDED. INGESTED:DO NOT
INDUCE VOMITING. GIVE 1-2 GLASSES OF MILK OR WATER TO DRINK. GET
IMMEDIATE MEDICAL ATTENTION. NOTHING BY MOUTH IF UNCONSCIOUS.
Fire Fighting
Lower Limits:4.1,HYDROGEN
Upper Limits:74.2HYDROGEN
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:IF BATTERIES ON CHARGE, SHUT OFF POWER. USE
POSITIVE PRESSURE SCBA. WATER APPLIED TO ACID GENERATES HEAT AND
CAUSES SPATTER. WEAR ACID RESISTANT CLOTHING.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE HYDROGEN GAS IS
GENERATED DURING CHARGING & OPERATION OF BATTERY. TO AVOID RISK OF
FIRE OR EXPLOSION, KEEP SPARKS AWAY FROM BATTERIES.
Accidental Release
Spill Release Procedures:STOP FLOW OF MATERIAL, CONTAIN/ABSORB SPILL
W/SAND, EARTH, VERMICULITE. DO NOT USE COMBUSTABLE MATERIALS.
NEUTRALIZE W/SODA ASH, SODIUM BICARBONATE, LIME. WEAR
ACID-RESISTANT CLOTHING, BOOTS & FACE SH IELD.
Neutralizing Agent:SODA ASH (SODIUM CARBONATE), BAKING SODA, OR QUICK
LIME (CALCIUM OXIDE).
Handling
Handling and Storage Precautions:STORE IN UNDER ROOF IN A COOL, DRY,
WELL-VENTILATED AREA AWAY FROM INCOMPATIBLES. STORE IN AREA
APPROPRIATE FOR ACID SPILLS.
Other Precautions:USE CARE TO AVOID ELECTRIC SHOCK FROM CHARGING
EQUIPMENT. SHUT OFF POWER TO CHARGERS WHEN NOT IN USE & BEFORE
DETACHING BATTERY. KEEP CHARGING SPACE VENTILATED. KEEP VENT CAPS
IN POSITION. KEEP SOURCE S OF IGNITION OUT OF CHARGING AREA.
Exposure Controls
Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS. WHEN
CONCENTRATIONS OF SULFURIC ACID MIST ARE KNOWN TO EXCEED PEL, USE
NIOSH OR MSHA-APPROVED RESPIRATORY PROTECTION.
Ventilation:STORE & HANDLE IN WELL VENTILATED AREAS. IF MECHANICAL
VENTILATION IS USED, COMPONENTS MUST BE ACID-RESISTANT.
Protective Gloves:RUBBER/PLASTIC GLOVES W/GAUNTLET.
Eye Protection:CHEMICAL GOGGLES OR FACE SHIELD.
Other Protective Equipment:ACID-RESISTANT APRON. UNDER SEVERE EXPOSURE
OR EMERGENCY CONDITIONS, WEAR ACID-RESISTANT CLOTHING & BOOTS.
Work Hygienic Practices:HANDLE BATTERIES CAUTIOUSLY. AVOID SPILLS. KEEP
VENT CAPS IN PLACE. AVOID CONTACT W/INTERNAL PARTS. WEAR PROTECTIVE
EQPT
Supplemental Safety and Health
IN AREAS WHERE SULFURIC ACID IS HANDLED IN CONCENTRATIONS GREATER THAN
1%, EMERGENCY EYEWASH STATIONS AND SHOWERS SHOULD BE PROVIDED, WITH
UNLIMITED WATER SUPPLY. **SUPERVISOR ORDERED ENTRY OF HCC COD E &
PROPER SHIPPING NAME AS ASSIGNED BYTECH SUPPORT PERSONNEL. SEE ADD
DATA FOR FURTHER COMMENTS.
Chemical Properties
HCC:C1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:203F,95C
Melt/Freeze Pt:M.P/F.P Text:N/A.
Vapor Pres:17 TO 11
Vapor Density:>1
Spec Gravity:1.230-1.350
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:100%
Appearance and Odor:CLEAR LIQUID W/SHARP PENETRATING, PUNGENT ODOR.
BATTERY IS A MANAFACTURED ARTIC
Stability
Stability Indicator/Materials to Avoid:YES
COMBUSTABLES, ORGANIC MATERIAL, STRONG REDUCING AGENTS, METALS, SULFUR
TRIOXIDE GAS, STRONG OXIDIZERS, WATER.
Stability Condition to Avoid:PROLONGED OVERCHARGE; SOURCES OF IGNITION.
Hazardous Decomposition Products:SULFUR TRIOXIDE, CARBON MONOXIDE,
SULFIRIC ACID MIST, SULFUR DIOXIDE, HYDROGEN.
Disposal
Waste Disposal Methods:SPENT BATTERIES:SEND TO SECONDARY LEAD SMELTER
FOR RECYCLING. PLACE NEUTRALIZED SLURRY INTO SEALED CONTAINERS &
DISPOSE OF AS HAZARDOUS WASTE, AS APPLICABLE. CONSULT STATE
ENVIRONMENTAL AGENCY &/OR FE DERAL EPA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.