Product Identification
Product ID:I-300,S-300,GPA(POLYMETHYLMETHACRYLATE,ACRYLIC)
MSDS Date:09/01/1993
FSC:8010
NIIN:00DOO6816
MSDS Number: CFDQB
Responsible Party
PITTSBURGH, PA 15219-2704
US
Emergency Phone: 412-433-7654 412-571-5888
Info Phone: 412-433-7654 412-571-5888
Cage: ARIST
Contractor
Telephone: 412-354-9859
Cage: NO672
Ingredients
BUTYL ACRYLATE-METHYL METHACRYLATE POLYMER
CAS: 25852-37-3
Fraction By Weight: 98%
COLORANT (MAY CONTAIN CADMIUM)
Fraction By Weight: 2%
CADMIUM (SARA 313) (CERCLA)
CAS: 7440-43-9
RTECS: EU9800000
OSHA PEL 0.2 MG/M3 DUST; Z-2
ACGIH TLV: 0.01 MG/M3 DUST;9495
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
Hazards
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:]HEATING OF THIS ITEM MAY CAUSE
RELEASE OF FREE METHYLMETHACRYLATE MONOMER. EYES:MAY CAUSE
IRRITATION. SKIN:MAY CAUSE IRRITATION & ALLERGIC SKIN REACTION
(FROM FREE METHYLMETHACRYLATE MONOMER IN THE N ATIVE PRODUCT).
INGESTION:MAY CAUSE G/IIRRITATION. INHALATION:MAY CAUSE SEVERE
RESPIRATORY IRRITATION, CNS DEPRESSION.
Explanation of Carcinogenicity:MAY CONTAIN CADMIUM & MONOMETHACRYLATE.
SEE THE INDIVIDUAL IARC & NTP REPORTS FOR DETAILS OF
CARCINOGENICITY.
Effects of Overexposure:INHALATION:COUGH, DIZZINESS, CONFUSION,
HEADACHE, DROWSINESS. SKIN:IRRITATION, ITCHING.
Medical Cond Aggravated by Exposure:PERSONS W/PRE-EXISTING SKIN &
RESPIRATORY AILMENTS MAY BE AT INCREASED RISK FROM EXPOSURE.
First Aid
First Aid:IF ANY IRRITATION PERSISTS OR SEVERE, GET MEDICAL ATTENTION.
EYE:FLUSH W/WATER FOR 15 MIN. SKIN:WASH W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. INHALED:REMOVE FROM
CONTAMINAT ED AREA. AID OR RESTORE BREATHING AS NEEDED.
Fire Fighting
Flash Point:N/A.
Autoignition Temp:Autoignition Temp Text:N/A.
Extinguishing Media:WATER, DRY CHEMICAL
Fire Fighting Procedures:WATER MAY BE USED TO COOL CONTAINERS. USE OF
SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED.
Unusual Fire/Explosion Hazard:FIRE CONDITIONS MAY EVOLVE TOXIC FUMES.
Accidental Release
Spill Release Procedures:SWEEP UP & DISPOSE OF PROPERLY.
Neutralizing Agent:MFR GAVE NO INFORMATION OF MSDS.
Handling
Handling and Storage Precautions:MFR GAVE NO INFORMATION OF MSDS.
Other Precautions:MATERIAL HAS SHARP EDGES;USE PROTECTIVE GLOVES WHEN
HANDLING. USE PROPER RESPIRATORY PROTECTION; AVOID BREATHING DUST.
Exposure Controls
Respiratory Protection:USE RESPIRATORY PROTECTION APPROVED FOR
PROTECTION AGAINST ORGANIC VAPORS & DUST. APPROPRIATE RESPIRATOR
DEPENDS ON TYPE & MAGNATUDE OF EXPOSURE.
Ventilation:USE LOCAL EXHAUST TO KEEP EXPOSURE
Protective Gloves:WORK GLOVES (SHARP EDGES)
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING, AS NEEDED. PROVIDE A
LOCAL EYE WASH STATION.
Work Hygienic Practices:MATERIAL HAS SHARP EDGES;USE PROTECTIVE GLOVES
WHEN HANDLING. USE PROPER RESPIRATORY PROTECTION; AVOID BREATHING
DUST.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:N1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:N/A.
Melt/Freeze Pt:M.P/F.P Text:N/A.
Vapor Pres:N/A.
Vapor Density:N/A.
Spec Gravity:N/A.
pH:N/A.
Solubility in Water:N/A.
Appearance and Odor:SOLID & ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:TEMPERATURES ABOVE 698F(370C).
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
MONOMERIC METHYLMETHACRYLATE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:MAY BE DISPOSED OF IN TRASH. FOR HAZARDOUS WASTE
REGULATIONS CALL 800-424-9346.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.