CFDTC - 888 7176 K-LAB CYAN DVLPR REPLENISHER,PROCESS K-14M,WORK SOL
- MSDS: CFDTC
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 888 7176 K-LAB CYAN DVLPR REPLENISHER,PROCESS K-14M,WORK SOL
- National Stock Number: 6750-00D006386
Product Identification
Product ID:888 7176 K-LAB CYAN DVLPR REPLENISHER,PROCESS K-14M,WORK SOL
MSDS Date:09/20/1996
FSC:6750
NIIN:00D006386
MSDS Number: CFDTC
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 800- 242-2424
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 95-100%
SODIUM SULFATE
CAS: 7757-82-6
RTECS: WE1650000
Fraction By Weight: 1-5%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
SODIUM HYDROXIDE (CERCLA)
CAS: 1310-73-2
RTECS: WB4900000
Fraction By Weight: <1%
OSHA PEL 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
4-(N-ETHYL-N-2-HYDROXYETHYL)-2-METHYLPHENYLENEDIAMINE
CAS: 25646-77-9
RTECS: KJ6477000
Fraction By Weight: <1.0%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXPECTED TO BE LOW HAZ FOR
RECOMMENDED HANDLING. EYES:CAUSES IRRITATION. SKIN:CAUSES IRRIT.MAY
CAUSE ALLERGIC SKIN REACTION. INGEST:EXPECTED TO BE LOW INGEST HAZ.
Explanation of Carcinogenicity:PER MSDS:CARCINOGENICITY
CLASSIFICATION:IARC/ACGIH/NTP/OSHA:NONE.
Effects of Overexposure:EYE/SKIN IRRITATION. ALLERGIC SKIN REACTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:IF SYMPTOMATIC MOVE TO FRESH AIR. GET MED ATTN IF
SYMPTONS PERSIST. EYES:IMMED FLUSH W/PLENTY OF WATER FOR @LEAST
15MINS. GET MED ATTN. SKIN:IMMED REMOVE CONTAM CLOTH/SHOES.WASH
W/SOAP/PLENTY OF WATER. GET MED ATTN. INGEST:DRINK 1-2 GLASSES OF
WATER. SEEK MED ATTN. NEVER GIVE ANYTHING BY MOUTH IF UNCONSC.
Fire Fighting
Flash Point:NONE,NON-COMBUST
Autoignition Temp:Autoignition Temp Text:NP
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:FLUSH TO SEWER W/LG AMTS OF WATER.OTHERWISE
ABSORB W/VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN
CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO REMOVE
RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID EYE/SKIN/CLOTH CONTACT.USE
W/ADEQU VENTI.ROUTINE USE OF NONALKALINE(ACID)TYP HNDCLNR/REG
WORKSURF/GLOVE/ETC CLEANING HELP MIN SKIN REACTION.
Other Precautions:KEEP CNTNR CLSD.KEEP AWAY FROM INCOMP SUBST.MATL
STRONGLY ALKALINE AQU SOLN.PROPERTIES:LOW BIOCHEM OXY DEMAND,LITTLE
POT TO CAUSE OXY DEPLETION IN AQU SOLN;MOD POT TO AFFECT SOME AQU
ORGANISMS;LOW POT TO AFFEFTS GERM &/OR EARLY GROWTH(SUPP)
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS, GOGGLES.
Other Protective Equipment:EYEBATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH CONTAM CLOTH BEF REUSE;DESTROY/CLEAN WELL
CONTAM SHOES.WASH THOROUGHLY AFTER HNDLG.
Supplemental Safety and Health
PH:12.0-12.2. OTHER PRECAUT:OF SOME PLANTS;LOW POT TO BIOCOCONE.WHEN
DILUTE W/LG AMT OF WATER MATL RELEASED DIR/INDIR INTO ENVIRO NOT
EXPECTED TO HAVE SIGNIFICANT IMPACT. PNIND:A(CONCEN);HCC=C2.
Chemical Properties
HCC:C2
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.03
pH:SUPPLE
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, ODORLESS
Percent Volatiles by Volume:95-100
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE (NON-COMBUSTIBLE)
Disposal
Waste Disposal Methods:DISCHARGE/TREATMENT/DISPOSAL MAY BE SUBJECT TO
NATIONAL/STATE/LOCAL LAWS. FLUSH TO SEWER W/LG AMTS OF WATER. CHEM
SUBJ TO SEC 313 TITLE III SARA/40CFR372 REPORTING REQMTS:NONE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.