CFDYC - TEL-TEK

Product Identification

Product ID:TEL-TEK
MSDS Date:01/01/1995
FSC:6850
NIIN:00D006855
MSDS Number: CFDYC

Responsible Party
RAMCO SPECIALTY PRODUCTS
5956 STATE ROAD
BAKERSFIELD, CA 93308-3022
US

Emergency Phone: 714-758-7795/80-255-3924

Info Phone: 800-334-7071/ FAX 714-635-0165

Preparer: LSS

Cage: 0AV13

Contractor
RAMCO SPECIALITY PRODUCTS
BAKERSFIELD, CA 93308-3022 US

Telephone: 714-758-7795

Cage: 0AV13

Ingredients

HEXANE (N-HEXANE) (CERCLA)

CAS: 110-54-3

RTECS: MN9275000

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLYTETRAFLUOROETHYLENE (FLUOROTELOMER)

CAS: 116-14-3

RTECS: KX4025000


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9596


ISOBUTANE

CAS: 75-28-5

RTECS: TZ4300000

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXCESS VAP INHAL CAN BE
HARMFUL,MAY CAUSE HEAD,DIZZ,ASPHYXIA,ANESTHETIC EFFECTS,POSSIBLE
UNCONSC.EYE/SKIN:POSSIBLE MILD IRRIT.INGEST:POSSIBLE CHEM
PNEUMONITIS IF ASPIRATED INTO LUNGS,NAU.CHRONIC EFFECTS:(EFFECTS
DUE TO EXCESS EXPO TORAW MATLS OF THIS MIXTURE)MAY CAUSE
CARDIAC/LIV ABNORMALITIES,KID &/OR LUNG DMG.
Explanation of Carcinogenicity:PER MSDS:CHEM LISTED AS CARC OR POT
CARC:NOT LISTED.
Effects of
Overexposure:INHAL-HARMFUL,HEADACHE,DIZZINESS,ASPHYXIA,ANESTHETIC
EFFECTS,UNCONSCIOUSNESS.EYE/SKIN MILD IRRIT.CHEM PNEUMONITIS IF
ASPIRATED INTO LUNGS,NAUSEA.CARDIAC & LIVER ABNORMALITIES, KIDENY
&/OR LUNG DAMAGE.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING EYE,SKIN OR
UPPER RESPIRATORY CONDITIONS.

First Aid

First Aid:EYE:FLUSH W/WATER FOR @LEAST 15MINS.IF IRRIT SEEK MED
ATTN.SKIN:WASH W/SOAP/WATER.IF IRRIT SEEK MED ATTN.INHAL:REMOVE TOF
RESH AIR.RESUSICITATE IF NECESSARY.GET MED ATTN.INGEST:DONT INDUCE
VOMITING.DR INK 2 LARGE GLASSES OF WATER.GET IMMED MED ATTN.

Fire Fighting

Flash Point:NA (SUPPLEMENTA)
Autoignition Temp:Autoignition Temp Text:NA
Lower Limits:N/E
Upper Limits:N/E
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:DO NOT EXPOSE AEROSOLS TO TEMPS ABOVE
120F OR THE CONTAINER MAY RUPTURE.

Accidental Release

Spill Release Procedures:ABSORB W/SUITABLE MEDIUM.INCINERATE OR
LANDFILL ACCORDING TO LOCAL, STATE AND FEDERAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DONT PUNCTURE OR INCINERATE
CONTAINERS.DONT STORE AT TEMPS ABOVE 120F.
Other Precautions:KEEP OUT OF REACHOF CHILDREN.AVOID FOOD
CONTAMINATION.AVOID BREATHING VAPORS.

Exposure Controls

Respiratory Protection:IF VAPOR CONCENTRATION EXCEEDS TLV USE
RESPIRATOR APPROVED BY US BUREAU OF MINES FOR ORGANIC VAPOR.
Ventilation:ADEQUATE VENTILATION TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:NEOPRENE GLOVES RECOMMENDED.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:NONE.
Work Hygienic Practices:WASH W/SOAP/WATER BEFORE HNDLG FOOD.REMOVE
CONTAMINATED CLOTHING.
Supplemental Safety and Health
FLAMMABILITY AS PER USA FLAME PROJECTION TEST:(AEROSOL)EXTREMELY
FLAMMABLE.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:50-60 AERO
Vapor Density:N/ESTIMATE
Spec Gravity:0.675 CONCEN
pH:NP
Viscosity:NP
Evaporation Rate & Reference:N/ESTIMATED
Solubility in Water:INSOLUBLE
Appearance and Odor:OPAQUE LIQUID, WITH SOLVENT ODOR
Percent Volatiles by Volume:NA
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:NO
ALKALINE METALS, WATER, STRONG OXIDIZING AGENTS, REACTIVE METALS SUCH
AS ALUMINUM & MAGNESIUM.
Stability Condition to Avoid:OPEN FLAME, WELDING ARCS, HEAT.
Hazardous Decomposition Products:CO2, CO,HF,PFIB,TFE,HEP AND
OLIGOMERS.ABOVE 800F TOXIC FLUORONATED GASES.

Disposal

Waste Disposal Methods:AEROSOL CANS WHEN VENTED TO ATMOSPHERIC PRESSURE
THROUGH NORMAL USE,POSE NO DISPOSAL HAZARD.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.