CFFJC - 028-780210-2

  • MSDS: CFFJC
  • Manufacturer: CONAX FLORIDA CORP
  • Product Name: 028-780210-2
  • National Stock Number: 4220-01-301-6362
Product Identification

Product ID:028-780210-2
MSDS Date:09/05/1997
FSC:4220
NIIN:01-301-6362
MSDS Number: CFFJC

Responsible Party
CONAX FLORIDA CORP
2801 75TH STREET N
SAINT PETERSBURG, FL 33710-2936
US

Emergency Phone: 813-345-8000

Info Phone: 813-345-8000

Preparer: DSCR-VBA(LEVIEN)

Cage: 62323

Contractor
CONAX FLORIDA CORP
SAINT PETERSBURG, FL 33710-2936 US

Telephone: 813-345-8000

Cage: 62323

Ingredients

CARBON DIOXIDE;MASS=0.51LBS

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 100%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;96

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CARBON DIOXIDE IS AN ASPHYXIANT. HIGH
CONCENTRATIONS CAN PRODUCE PARALYSIS OF THE RESPIRATORY CONTROL
CENTER OF THE NERVOUS SYSTEM. 2-3% WILL INCREASE RESPIRATION. >4%
PRODUCES LABORED BREATHING AND I S DANGEROUS FOR EVEN A FEW
MINUTES. >12% CAUSES RAPID UNCONSCIOUSNESS AND DEATH.
Explanation of Carcinogenicity:NONE OF THE INGREDIENTS IN THIS PRODUCT
IS LISTED BY NTP, IARC OR OSHA AS A CARCINOGEN.
Effects of Overexposure:FAINT "ACIDIC" TASTE, HEADACHE, DIZZINESS,
SHORTNESS OF BREATH, MUSCULAR WEAKNESS, DROWSINESS, AND RINGING OF
THE EARS.
Medical Cond Aggravated by Exposure:PERSONNEL WITH PRE-EXISTING CHRONIC
RESPIRATORY DISEASES OR HEART DISORDER SHOULD REFRAIN FROM
BREATHING EXCESSIVE CARBON DIOXIDE. RECOVERY IS USUALLY RAPID FROM
SHORT TERM OVEREXPOSURE.

First Aid

First Aid:FIRST AID: INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN/CPR
IF NEEDED. RESCUE PERSONNEL SHOULD WEAR SELF-CONTAINED BREATHING
APPARATUS WITH FULL FACE MASK.

Fire Fighting

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.

Accidental Release

Spill Release Procedures:REMOVE PERSONNEL. VENTILATE AREA. WEAR SELF-
CONTAINED BREATHING APPARATUS. MOVE LEAKING CONTAINER OUTDOORS IF
WITHOUT RISK. SLOWLY RELEASE INTO ATMOSHPHERE. RETURN DEFECTIVE
CYLINDER TO SUPPLIER. TES T AREA FOR OXYGEN BEFORE ALLOWING
RE-ENTRY.

Handling

Handling and Storage Precautions:STORE CARBON DIOXIDE CYLINDERS UPRIGHT
IN A COOL, DRY LOCATION, AWAY FROM CHEMICALS WITH SAFETY CAP
INSTALLED.
Other Precautions:NEVER WORK ON A PRESSURIZED SYSTEM. IF THERE IS A
LEAK, CLOSE THE CYLINDER VALVE, BLOW DOWN SYSTEM BY VENTING TO A
SAFE PLACE, THEN REPAIR LEAK.

Exposure Controls

Respiratory Protection:WEAR SELF-CONTAINED BREATHING APPARATUS WHEN
CONCENTRATIONS ARE ABOVE PEL.
Ventilation:MECHANICAL (GENERAL) AND/OR LOCAL EXHAUST VENTILATION TO
KEEP EXPOSURE LEVELS BELOW PEL.
Protective Gloves:LEATHER GLOVES.
Eye Protection:SAFETY GLASSES OF FULL FACE SHIELD.
Other Protective Equipment:SELF-CONTAINED BREATHING APPARATUS. SAFETY
SHOES. DO NOT WEAR CONTACT LENSES.
Work Hygienic Practices:KEEP SAFETY VALVES IN GOOD WORKING CONDITIONS.
KEEP DEBRIS AND UNNECESSARY EQUIPMENT AWAY FROM CO2 EQUIPMENT.
Supplemental Safety and Health
CLOSE VALVE WHEN NOT IN USE AND WHEN EMPTY. CARBON DIOXIDE, BEING
HEAVIER THAN AIR, TENDS TO ACCUMULATE NEAR THE FLOOR OF AN ENCLOSED
SPACE DISPLACING THE AIR AND CREATING AN OXYGEN DEFFICIENT ATMOSPH
ERE. VENTILATE BEFORE ENTRY. VERIFY SUFFICIENT OXYGEN
CONCENTRATION.

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:SUBLIMES
Melt/Freeze Pt:M.P/F.P Text:-108F,-78C
Spec Gravity:1.527
Solubility in Water:APPRECIABLE
Appearance and Odor:GAS,COLORLESS AND ODORLESS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
OF IGNITION
Hazardous Decomposition Products:IN THE PRESENCE OF AN ELECTRICAL
DISCHARGE, CARBON DIOXIDE IS DECOMPOSED TO FORM CARBON MONOXIDE AND
OXYGEN.

Disposal

Waste Disposal Methods:CONTACT YOUR LOCAL ENVIRONMENTAL OFFICER.
MANUFACTURER RECOMMENDS VENTING SLOWLY TO ATMOSPHERE WITH ADEQUATE
VENTILATIONS. DISPOSE OF IN ACCORDANCE WITH ALL FEDERAL, STATE AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.