CFHFW - NIMH BATTERY, SEALED, CL4057C
- MSDS: CFHFW
- Manufacturer: ALEXANDER MFG CO
- Product Name: NIMH BATTERY, SEALED, CL4057C
- National Stock Number: 6140-00N078054
Product Identification
Product ID:NIMH BATTERY, SEALED, CL4057C
MSDS Date:02/01/1996
FSC:6140
NIIN:00N078054
MSDS Number: CFHFW
Responsible Party
MASON CITY, IA 50401
US
Emergency Phone: 515-423-8955
Info Phone: 515-423-1161
Cage: 56469
Contractor
Telephone: 515-423-1161/8955
Cage: 56469
Ingredients
NICKEL & NICKEL HYDROXIDE
Fraction By Weight: 20-30%
OSHA PEL N/K
ACGIH TLV: N/K
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-4%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION:DURING FIRE INVOLVING LARGE
QUANTITIES OF BATTERIES, FUMES MAY BE RELEASED. EYE:IF BATTERY
RUPTURES, SKIN MAY COME IN CONTACT W/TRACE AMOUNT OF POTASSIUM
HYDROXIDE, WILL CAUSE A BURN. SKIN: IF BATTERY RUPTURES, SKIN MAY
COME IN CONTACT W/TRACE AMOUNT OF POTASSIUM HYDROXIDE, WILL CAUSE
BURN. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL COMPOUNDS:IARC MONO ON EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GROUP 2B. NTP 7TH
ANNUAL(SUPDAT)
Effects of Overexposure:HLTH HAZ:ACUTE AND CHRONIC:NOT APPLICABLE.
SIGNS & SYMPTOMS OF EXPOSURE: NOTE:UNDER NORMAL USE, CL4206 BATTERY
DOES NOT RELEASE TOXIC MATERIAL.
Medical Cond Aggravated by Exposure:NOT APPLICABLE.
First Aid
First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD
( ). SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .
Fire Fighting
Extinguishing Media:NO INFORMATION AVAILABLE. MEDIA SUITABLE FOR
SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WAREHOUSE OR DEPOT TYPE STORAGE.
Unusual Fire/Explosion Hazard:FUMES MAY BE RELEASED DURING BURNING.
Accidental Release
Spill Release Procedures:ELECTROLYTE. POTASSIUM HYDROXIDE IS CAUSTIC.
DO NOT ALLOW SKIN OR EYE CONTACT. FLUSH WITH WATER. THERE IS ONLY A
TRACE AMOUNT OF POTASSIUM HYDROXIDE AVAILABLE IN THE BATTERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT INCINERATE OR MUTILATE:MAY
BURST RELEASING TOXIC MATERIAL.
Other Precautions:DO NOT SHORT CIRCUIT THE BATTERY, IT MAY CAUSE BURNS
WHEN IN CONTACT WITH THE SKIN OR EYES.
Exposure Controls
Respiratory Protection:NOT APPLICABLE. NIOSH APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:REPORT ON CARCINOGENS, 1994:ANTICIPATED TO BE
CARCINOGEN. HUMAN:LUNGS, NASAL CAVITIES.
Chemical Properties
Evaporation Rate & Reference:NOT KNOWN
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:BURNING (FIRE), RUPTURING.
Hazardous Decomposition Products:FUMES MAY BE RELEASED DURING A FIRE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.