CFHTS - HI-TECH ENAMELS, 16-214

  • MSDS: CFHTS
  • Manufacturer: SEYMOUR OF SYCAMORE INC
  • Product Name: HI-TECH ENAMELS, 16-214
  • National Stock Number: 8010-00N078522
Product Identification

Product ID:HI-TECH ENAMELS, 16-214
MSDS Date:01/01/1993
FSC:8010
NIIN:00N078522
MSDS Number: CFHTS

Responsible Party
SEYMOUR OF SYCAMORE INC
917 CROSBY AVE
SYCAMORE, IL 60178
US

Emergency Phone: 800-255-3924

Info Phone: 815-895-9101

Cage: 59581

Contractor
SEYMOUR OF SYCAMORE
SYCAMORE, IL 60178-1343 US

Telephone: 815-895-9101/800-255-3924

Cage: 59581

Ingredients

.19-8.20

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: SEE ING

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9495


1.00%

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: SEE ING

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL;9495

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


1.97-3.45

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: SEE ING

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/125STEL;9495

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2.60%

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: SEE ING

OSHA PEL 1000 PPM

ACGIH TLV: 750PPM/1000STEL;9495

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


0.20-0.55

CAS: 8032-32-4

RTECS: OI6180000

Fraction By Weight: SEE ING

OSHA PEL 300 PPM

ACGIH TLV: 300 PPM; 9495


KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS) % WT

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: SEE ING

OSHA PEL N/K

ACGIH TLV: 100 MG/M3 (MFR)


ETHANOL, 2-PROPOXY-; (ETHYLENE GLYCOL MONOPROPYL ETHER) %

CAS: 2807-30-9

RTECS: KM2800000

Fraction By Weight: SEE ING

OSHA PEL N/K

ACGIH TLV: N/K


.90%

CAS: 64742-94-5

RTECS: WF3100000

Fraction By Weight: SEE ING

OSHA PEL N/K

ACGIH TLV: N/K


2.30

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: SEE ING

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9495


1.90

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: SEE ING

OSHA PEL N/K

ACGIH TLV: N/K


2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (HEXONE)

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: 3.52%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM/75 STEL; 9495

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


DIZZ, WEAK,

RTECS: 9999999ZZ


DEATH. GI IRRIT, VOMIT, & DIARR. ASPIR CAN CAUSE

RTECS: 9999999ZZ


& MUC MEMB OF THE NOSE & THROAT. CAN CAUSE CNS

RTECS: 9999999ZZ


INTOXICATING; EARLY EMOTIONAL INSTABILITY,

RTECS: 9999999ZZ


SKIN IRRIT. CNS

RTECS: 9999999ZZ


HUMAN

RTECS: 9999999ZZ


SHOULD BE MINIMIZED. IRRIT TO THE EYES & RESP TRACT.

RTECS: 9999999ZZ


CENTRAL NERVOUS SYSTEM DEPRESSION AND

RTECS: 9999999ZZ


TRACT IRRITATION, AND GASTROINTESTINAL SYMPTOMS.

RTECS: 9999999ZZ


FOR MORE SPECIFIC INFORMATION CONTACT NEHC .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL:EXPOS TO SOLV VAPS CONC
EXCEEDING ESTABLISHED THRESHOLD LIM VALUES CAN CAUSE RESP SYS
IRRIT. SYMP OF OVEREXP ARE IRRIT, HDCH, DIZZ, NAUS, POSS
UNCONSCIOUSNESS, & ASPHY. EYE:MAY CAUSE IRRI T ESP UPON DIRECT
CNTCT W/SPRAY. SKIN:PRLNG/RPTD LIQ CNTCT MAY CAUSE DEFAT OF SKIN,
LEADING TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:IRRIT & DERM. CHRONIC:ING 1:INHAL
TESTS IN RATS DUST FROM DRIED PROD PRODUCED AN INERT/NAUSANCE DUST
RESPONSE IN LUNGS. ING 2:HUMAN HLTH RISK MAY VARY FROM PERS TO
PERS. EXPOS SHOULD BE MINIM IZED. ANIMAL TEST STUDIES HAVE SHOWN
POSS EFTS TO:LIVER, KIDNEYS, & LUNGS. ANIMAL TEST STUDIES HAVE
SHOWN (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: REMOVE PATIENT TO FRESH AIR. IF BREATHING STOPS,
BEGIN ARTIFICIAL RESPIRATION. SEEK MEDICAL ATTENTION. EYE:
IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER.
INGESTION: ACCIDENTAL INGESTION IS UNLIKELY FROM AN AEROSOL CAN. IF
INGESTED, CALL A PHYSICIAN IMMEDIATELY.

Fire Fighting

Flash Point Method:TOC
Flash Point:-10F,-23C
Lower Limits:SEE ING
Upper Limits:9.5%
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, OR FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. H*2O MAY BE USED TO COOL CNTNRS TO PVNT
BURSTING. IF H*2O IS USED, FOG (SUPDAT)
Unusual Fire/Explosion Hazard:EXPOSURE TO HEAT MAY CAUSE BURSTING OF
AEROSOL CAN.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, AVOID
BREATHING VAPORS, VENTILATE AREA. WIPE UP WITH INERT MATERIAL AND
PLACE IN APPROPRIATE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120 DEG. F.
EXPOSURE TO HEAT OR PROLONGED EXPOSURE TO SUN MAY CAUSE BURSTING.
Other Precautions:USE ONLY AS DIRECTED. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING VAPORS AND INHALING CONTENTS CAN BE
HARMFUL OR FATAL.

Exposure Controls

Respiratory Protection:AVOID CONTINUOUS BREATHING OF VAPORS AND SPRAY
MIST. A NIOSH APPROVED SELF CONTAINED BREATHING APPARATUS REQUIRED
FOR CONCENTRATIONS ABOVE TLV LIMITS.
Ventilation:USE WITH ADEQUATE VENTILATION, SUFFICIENT TO PREVENT
INHALATION OF SOLVENT VAPORS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA. .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:NOZZLES ARE PREF. EFTS OF OVEREXP:EMBRYO/FETOXIC EFTS.
RELEVANCE UNKNOWN. HIGH VAPOR CONC ARE IRRIT TO EYES & RESP TRACT.
MAY CAUSE HDCH & DIZZ, ARE ANSETHETIC & MAY HAVE OTHER NERVOUS SYS
EFTS INCL DEATH. ING 3:SEVERE EYE IRRIT, REDNESS TEARING, & BLURRED
VISION. CAN CAUSE IRRIT, DEFAT, & (ING 12)

Chemical Properties

Vapor Pres:40 @ 70F
Vapor Density:HVR/AIR
Spec Gravity:0.72-0.84
Evaporation Rate & Reference:FASTER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:PAINT SOLVENT ODOR
Percent Volatiles by Volume:64-85

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STRONG ACIDS AND STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:DO NOT STORE ABOVE 120 DEG. F. KEEP FROM
SPARKS, PILOT LIGHTS, OR OPEN FLAMES.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS FUMES WHEN
HEATED TO DECOMPOSITION. FUMES MAY CONTAIN CARBON DIOXIDE AND/OR
CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DO NOT INCINERATE AEROSOL, DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS. DO NOT PLACE
CANS IN HOME COMPACTOR. DO NOT PUNCTURE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.