CFLFD - 802300-14 EMERGENCY ESCAPE BREATHING DEVICE
- MSDS: CFLFD
- Manufacturer: SCOTT AVIATION DIV OF FIGGIE INTL INC
- Product Name: 802300-14 EMERGENCY ESCAPE BREATHING DEVICE
- National Stock Number: 4240-01-217-0046
Product Identification
Product ID:802300-14 EMERGENCY ESCAPE BREATHING DEVICE
MSDS Date:10/01/1997
FSC:4240
NIIN:01-217-0046
MSDS Number: CFLFD
Responsible Party
LANCASTER, NY 14086
US
Emergency Phone: 716-683-5100
Info Phone: 716-683-5100/FAX 716-681-1089
Cage: 53655
Contractor
Telephone: 716-683-5100
Cage: 15927
Ingredients
INGREDIENTS 11-15 ARE FOR SCRUBBER-IF APPLICABLE?
SODIUM CHLORATE
CAS: 7775-09-9
RTECS: FO0525000
Fraction By Weight: <90%
BARIUM PEROXIDE
CAS: 1304-29-6
RTECS: CR0175000
Fraction By Weight: <7%
OSHA PEL 5 MG BA/M3
ACGIH TLV: 2 MG BA/M3
POTASSIUM PERCHLORATE
CAS: 7778-74-7
RTECS: SC9700000
Fraction By Weight: <2%
IRON
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: <7%
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: <5%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.1 MG/M3 RDUST;9596
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: <3%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9596
MICA - SILICATES (< 1% CRYSTALLINE SILICA)
CAS: 12001-26-2
RTECS: VV8760000
Fraction By Weight: <2%
OSHA PEL 20 MPPCF; Z-3
ACGIH TLV: 3 MG/M3 RDUST; 9596
MAGNESIUM OXIDE
CAS: 1309-48-4
RTECS: OM3850000
Fraction By Weight: <0.2%
OSHA PEL 15 MG/M3 PARTICULATE
ACGIH TLV: 10 MG/M3; FUME; 9596
TALC (CONTAINING NO ASBESTOS)
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: <2%
OSHA PEL 20 MPPCF Z-3
ACGIH TLV: 2 MG/M3 RDUST; 9596
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: <0.1%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5MG(FE)/M3FUME,B2;96
LITHIUM HYDROXIDE
CAS: 1310-65-2
RTECS: OJ6307070
SILICA GEL (MOLECULAR SIEVE)
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: <60%
OSHA PEL 6 MG/M3
ACGIH TLV: 10 MG/M3
ALPHA-ALUMINA (ALUMINUM OXIDE) (SARA 313)
CAS: 1344-28-1
RTECS: BD1200000
Fraction By Weight: <40%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9596
SODIUM OXIDE
CAS: 1313-59-3
Fraction By Weight: <20%
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: <1%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.1 MG/M3 RDUST;9596
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT CAN BURN. SKIN CONTACT CAN
BE IRRITATING; MAY CAUSE RASH. INGESTION MAY BE TOXIC; BARIUM &
SODIUM CHLORATE ARE BOTH TOXIC BY INGESTION-REPORTED LETHAL DOSES
OF SODIUM CHLORATE ARE 2 GRAMS FOR CHILDREN & 15-30 GRAMS FOR
ADULTS. INHALATION MAY CAUSE IRRITATION OF MUCOUS MEMBRANES, THROAT
& NOSE.
Explanation of Carcinogenicity:NTP LISTS SILICON DIOXIDE, TALC &
QUARTZ. IARC LISTS SILICON DIOXIDE.
Effects of Overexposure:EYE-BURNS. SKIN-IRRITATION, RASH.
INGESTION-BOTH BARIUM & SODIUM CHLORATE ARE TOXIC.
INHALATION-IRRITATION TO THE MUCOUS MEMBRANES, THROAT & NOSE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-FLUSH WITH WATER FOR
15 MINUTES, HOLD LIDS APART. SKIN-WASH WITH MILD SOAP & WATER.
INHALED-AVOID BREATHING DUST. REMOVE TO FRESH AIR. INGESTED-CONTACT
PHYSICI AN IMMEDIATELY.
Fire Fighting
Extinguishing Media:WATER! OXIDIZERS GENERATE THEIR OWN OXYGEN AS THEY
BURN & CANNOT BE EXTINGUISHED BY MEANS OTHER THAN WATER.
Fire Fighting Procedures:AVOID BODILY CONTACT. WEAR SELF-CONTAINED
BREATHING APPARATUS & PROTECTIVE EQUIPMENT. KEEP MATERIAL FROM
EXPOSURE TO HIGH HEAT BY USING WATER TO COOL & DILUTE.
Unusual Fire/Explosion Hazard:DO NOT USE CO2 OR DRY EXTINGUISHERS AS
THEY ARE INEFFECTIVE & MAY CREATE A WORSE SITUATION.
Accidental Release
Spill Release Procedures:LOOSE CHEMICALS & COMPONENTS SHOULD BE
CAREFULLY PLACED INTO A DRY METAL CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:MAINTAIN AT NORMAL, AMBIENT
TEMPERATURE & PRESSURE. DO NOT STORE IN WET OR MOIST ENVIRONMENTS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES IF HANDLING CORE/DUST.
Eye Protection:NONE SPECIFIED BY MANUFACTURER.
Other Protective Equipment:WEAR IMPERVIOUS GLOVES IF HANDLING THE
CHEMICAL CORE OR DUST FROM THE CHEMICAL CORE. LAUNDER CONTAMINATED
CLOTHING.
Work Hygienic Practices:WASH AFTER HANDLING CORE CHEMICALS OR DUST FROM
CHEMICAL CORE BEFORE EATING, DRINKING, OR SMOKING.
Supplemental Safety and Health
THIS DEVICE IS A SOLID STATE CHEMICAL GENERATOR AND CLASSIFIED AS AN
"ARTICLE" IN 29 CFR 19100.1200(C), AND DOES NOT REQUIRE AN MSDS.
HOWEVER, FOR FEDERAL PROCUREMENT, AN MSDS IS REQUIRED PER APPENDIX
A FEDERAL STANDARD NO. 313, 10.1.3(D) WHICH LISTS OXIDIZERS AS
HAZARDOUS BY DEFINTION IN 49 CFR 173.151.
Chemical Properties
HCC:D1
NRC/State Lic Num:NONE
Spec Gravity:VARIES
pH:ALKALI
Solubility in Water:APPRECIABLE
Appearance and Odor:GREY COMPRESSED, CHEMICAL CORE ENCASED WITHIN A
METAL GENERATOR CANISTER.
Stability
Stability Indicator/Materials to Avoid:YES
OILS, ORGANIC METALS & ACIDS.
Stability Condition to Avoid:AVOID STORING, MIXING OR CONTAMINATING W/
CHEMICALS, MINERAL ACIDS & COMBUSTIBLE MATERIALS.
Hazardous Decomposition Products:CAN INCLUDE CHLORINE & CHLORINE
DIOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:GENERATORS MUST BE SPENT PRIOR TO DISPOSAL. DUE
TO THE BARIUM WITHIN THE GENERATOR IT IS CONSIDERED A HAZARDOUS
WASTE EVEN AFTER IT IS SPENT. SPENT GENERATOR MUST BE DISPOSED OF
IN ACCORDANCE WITH LOC AL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.