CFNQX - FLUORESCENT, FL-6 RED

  • MSDS: CFNQX
  • Manufacturer: PLASTI KOTE CO INC
  • Product Name: FLUORESCENT, FL-6 RED
  • National Stock Number: 8010-00N027320
Product Identification

Product ID:FLUORESCENT, FL-6 RED
MSDS Date:08/26/1994
FSC:8010
NIIN:00N027320
MSDS Number: CFNQX

Responsible Party
PLASTI-KOTE CO INC
1000 LAKE RD
MEDINA, OH 44256
US

Emergency Phone: 216-725-4511

Info Phone: 216-725-4511

Cage: 07778

Contractor
TEMPO PRODUCTS CO A PLASTI-KOTE CO INC
MEDINA, OH 44256 US

Telephone: 330-725-4511

Cage: 07708

Ingredients

38 @ 20C

CAS: 64742-89-8

Fraction By Weight: 40-45%

OSHA PEL N/K

ACGIH TLV: 300 PPM (MFR)


SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (AROMATIC

CAS: 64742-95-6

RTECS: WF3400000

Fraction By Weight: 0-5%

OSHA PEL N/K

ACGIH TLV: 100 PPM (MFR)


2.0 @ 20C

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 10-15%

OSHA PEL N/K

ACGIH TLV: 100 PPM (MFR)


HYDROCARBON PROPELLANT (PROPANE/ISOBUTANE);

CAS: 68476-86-8

Fraction By Weight: 20%

OSHA PEL 1000 PPM (MFR)

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: EXCESS INHAL OF VAPS CAN
CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH, POSS UNCON
& EVEN ASPHY. EYES: CAN CAUSE SEV IRRIT, REDNESS, TEARING, BLURRED
VISION. INGEST: CAN CAUSE G I IRRIT, NAUS, VOMIT, DIARR. SKIN: CAN
CAUSE IRRIT. CHRONIC: RPTS HAVE ASSOC RPTD & PRLNG OCCUP (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: OVEREXP TO SOLVS W/PERM BRAIN & NERV
SYS DMG. SEV OVEREXP IN LAB ANIMALS HAS ALSO CAUSED LIVER
ABNORMALITIES & DMG TO KIDNEYS, LUNGS, & SPLEEN, HEART & ADRENALS.
INTENTIONAL MISUSE BY DELIBE RATELY CONCENTRATING & INHALING
CONTENTS MAY BE HARMFUL/FATAL.
Medical Cond Aggravated by Exposure:CAN CAUSE RESPIRATORY AND/OR SKIN
REACTION.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF BRTHG IS DFCLT, ADMIN OXYGEN.
IF BRTHG HAS STOPPED, GIVE ARTF RESP & SEEK MED HELP. EYES: FLUSH
W/WATER FOR AT LEAST 15 MIN WHILE HOLDING EYELIDS OPEN. INGEST: DO
NOT IN DUCE VOMIT (ASPIR OF MATL INTO LUNGS CAN CAUSE PNEUMIT,
WHICH CAN BE FATAL). KEEP PERS WARM, QUIET & GET MED ATTN/POIS CTL
CTR. SKIN: WASH W/SOAP & WATER/VARIOUS HAND CLEANERS, & WASH
CLOTHING.

Fire Fighting

Flash Point Method:TCC
Flash Point:0F,-18C
Lower Limits:1.0%
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFFECTIVE. WATER MAY BE USED TO COOL CLSD
CONTRS TO PVNT PRESS BUILD-UP & POSS (SUP DAT)
Unusual Fire/Explosion Hazard:CLSD CONTRS MAY EXPLODE &/AUTOIGNITE WHEN
EXPOSED TO EXTREME HEAT. VAPS ARE HVR/AIR & MAY TRAVEL ALONG
GROUND/MAY BE MOVED BY VENT & IGNITED BY PILOT (SUP DAT)

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. VENTILATE
AREA. ABSORB LIQUID ON PAPER, VERMICULITE, FLOOR ABSORBENT, OR
OTHER ABSORBENT MATERIAL AND TRANSFER TO A CLOSED CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT PUNCTURE OR INCINERATE. DO NOT
STORE ABOVE 120F, OR IN DIRECT SUNLIGHT, OR NEAR HEAT OR OPEN
FLAMES.
Other Precautions:STORE LARGE QUANTITIES IN BUILDINGS PROTECTED FOR
STORAGE OF FLAMMABLE LIQUIDS.

Exposure Controls

Respiratory Protection:FOR CASUAL/OCCAS USE-TO AVOID BRTHG VAPS/SPRAY
MIST, OPEN WINDOWS & DOORS/USE OTHER MEANS TO ENSURE FRESH AIR
ENTRY DURING APPLICATION & DRYING. IF YOU EXPERIENCE EYE WATERING,
HDCH/DIZZ, INCR FRESH A IR, WEAR RESP PROT (NIOSH TC23C(SUP DAT)
Ventilation:FOR REGULAR/CONTINUOUS USE-PROVIDE SUFFICIENT MECHANICAL
(GEN) AND/OR LOCAL EXHAUST VENT TO MAINTAIN EXPOS BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT, SUCH AS NEOPRENE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
WHERE SPECIAL/UNUSUAL CNDTNS EXIST, SEEK EXPERT ASSIST OF AN (SUP
DAT)
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING WASHROOM. AS
WITH ALL CHEMICALS, MINIMIZE PERSONAL CONTACT.
Supplemental Safety and Health
FIRE FIGHT PROC: AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT. IF WATER
IS USED, FOG NOZZ ARE PREF. EXPLO HAZ: LIGHTS, OTHER FLAMES, SPKS,
HEATERS, SMKNG, ELEC MOTORS/OTHER LOCATIONS DISTANT FROM MATL
HNDLG POINT. RESP PROT: OR EQUIVALENT)/LEAVE AREA. OTHER PROT
EQUIP: INDUSTRIAL HYGIENIST.

Chemical Properties

Boiling Pt:B.P. Text:>133F,>56C
Melt/Freeze Pt:M.P/F.P Text:1500F,816C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:<1 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:SLIGHT TO MODERATE
Appearance and Odor:TYPICAL SOLVENT PAINT
Percent Volatiles by Volume:80-90

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS AND HEAT.
Stability Condition to Avoid:HEAT, SPARKS, AND OPEN FLAME.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS, CARBON
DIOXIDE/CARBON MONOXIDE, VARIOUS HYDROCARBONS, NITROGEN COMPOUNDS,
ETC, WHEN BURNED.

Disposal

Waste Disposal Methods:MATERIAL COLLECTED ON ABSORBENT MATERIAL MAY BE
DEPOSITED IN A POSTED TOXIC SUBSTANCES LANDFILL IN ACCORDANCE WITH
LOCAL, STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.