CFPHP - M115

  • MSDS: CFPHP
  • Manufacturer: BLOUNT INC
  • Product Name: M115
  • National Stock Number: 1395-00N078320
Product Identification

Product ID:M115
MSDS Date:01/01/1995
FSC:1395
NIIN:00N078320
MSDS Number: CFPHP

Responsible Party
BLOUNT INC
2299 SNAKE RIVER AVE
LEWISTON, ID 83501
US

Emergency Phone: 208-746-2351

Info Phone: 208-746-2351

Cage: BLOUN

Contractor
OMARK CCI,INC
39 ONALASKA, WI 54650 US

Telephone: 608-781-5800

Cage: 13723

Ingredients

< 0.1-1.75

CAS: 15245-44-0

Fraction By Weight: <1.75%

OSHA PEL N/K

ACGIH TLV: N/K


1-TETRAZENE, 1-GUANYL-4-NITROSAMINOGUANYL-; (TETRACENE) %

CAS: 109-27-3

RTECS: XF6900000

Fraction By Weight: <0.25%

OSHA PEL N/K

ACGIH TLV: N/K


< 0.1-1.50

CAS: 10022-31-8

RTECS: CQ9625000

Fraction By Weight: <1.50%

OSHA PEL 5 MG BA/M3

ACGIH TLV: 2 MG BA/M3


< 0.1-0.75

CAS: 12627-52-0

RTECS: CC9450000

Fraction By Weight: <0.75%

OSHA PEL N/K

ACGIH TLV: N/K


COPPER (SARA 313) (CERCLA)

CAS: 7440-50-8

RTECS: GL5325000

Fraction By Weight: 60-70%

OSHA PEL 0.1MG/M3 FUME/1 DUST

ACGIH TLV: 0.2 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ZINC COMPOUNDS (SARA 313) (CERCLA)

CAS: 7440-66-6

RTECS: ZG8600000

Fraction By Weight: 25-30%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PENTAERYTHRITOL TETRANITRATE; (PETN)

CAS: 78-11-5

RTECS: RZ2620000

Fraction By Weight: 0-0.25%

OSHA PEL N/K

ACGIH TLV: N/K


IF LEFT UNTREATED, WEAK, INSOMNIA,

RTECS: 9999999ZZ


IN MOUTH, ANEMIA, CONSTIP, HDCH, MUSCLE & JOINT

RTECS: 9999999ZZ


ENCEPHALOPATHY, & DMG TO REPRO SYS IN BOTH MALES &

RTECS: 9999999ZZ


HAZARD LIST. SEEK CONSULTATION FROM APPROPRIATE

RTECS: 9999999ZZ


INFORMATION AND SAFE HANDLING AND EXPOSURE

RTECS: 9999999ZZ


PRESENT UNLESS PROD IS FIRED/OTHERWISE

RTECS: 9999999ZZ


& SHIPPING SHOULD NOT CAUSE EXPOS TO THESE HAZS.

RTECS: 9999999ZZ


LEAD & ITS INORG CMPDS ARE NEUROTOXINS

RTECS: 9999999ZZ


OF LEAD EXPOS, CONSULT OCCUP SFTY & HLTH ADMIN

RTECS: 9999999ZZ


ALL STEPS OF THE ABOVE PROCESS SHOULD BE

RTECS: 9999999ZZ


TIME-WEIGHTED AVERAGE, USE HEARING

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: AFTER PRIMERS HAVE BEEN
FIRED, DUST, VAP &/FUMES MAY BE IRRIT TO RESP SYS & CAN RSLT IN
BOTH ACUTE & CHRONIC OVEREXP. SKIN CONT: AFTER PRIMERS HAVE BEEN
FIRED, DUST, VAP &/FUMES MAY CAUS E IRRIT. FRAGMENTED PROJECTILES
FROM PRIMERS CAN CAUSE PUNCTURE WOUNDS. SKIN ABSORPTION: AFTER
PRIMERS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: HAVE BEEN FIRED, DUST, VAP &/FUMES
ARE NOT READILY ABSORBED THRU SKIN. EYES: AFTER PRIMERS HAVE BEEN
FIRED, DUST, VAP &/FUMES MAY CAUSE IRRIT. INGEST: WHEN PRIMERS ARE
FIRED/OTHERWISE DISCHA RGED, DUST, VAP &/FUMES MAY BE ABSORBEDBY
DIGESTIVE SYS, & CAN RSLT IN BOTH ACUTE & CHRONIC OVEREXP. (SUP
DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/COPIOUS QTYS OF WATER FOR AT LEAST 15 MIN. GET
MED ATTN. IF PHYSICAL INJURY HAS OCCURRED BECAUSE OF PROJECTILES,
GET IMMED MED ATTN. SKIN: WASH THORO W/SOAP & WATER. IF PHYSICAL
INJURY H AS OCCURRED BECAUSE OF PROJECTILES, GETIMMED MED ATTN.
INHAL: REMOVE FROM EXPOS. GET MED ATTN IF EXPERIENCING EFTS OF
OVEREXP. INGEST: GET IMMED MED ATTN. ALL HAZARDS ARE NOT EXPECTED
TO BE (ING 13)

Fire Fighting

Extinguishing Media:WATER. FOG-TYPE SPRAY TO COOL SURROUNDING
ATMOSPHERE AND COMBUSTIBLES AND TO LOWER TEMPERATURE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:FLAMMABLE AND EXPLOSIVE MATERIAL. PRODUCT
MAY EXPLODE IF HEATED ABOVE 200C (392F).

Accidental Release

Spill Release Procedures:SCRAP PRIMERS SHOULD BE STORED IN A CONTAINER
OF WATER TO WHICH DETERGENT HAS BEEN ADDED AS A "WETTING" AGENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. DO NOT
CRUSH, DROP, OR PUNCTURE CONTAINER. AVOID HEAT, ELECTRICAL CURRENT,
ACIDS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:IF AIRBORNE CONCENTRATIONS EXCEED PEL, WEAR
NIOSH APPROVED RESPIRATORY PROTECTION IN ACCORDANCE WITH OSHA
STANDARD 29 CFR 1910.134.
Ventilation:MECHANICAL: MUST BE PROVIDED IF NECESSARY TO KEEP EXPOSURE
LEVELS BELOW LISTED TLV AND/OR PEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYEWASH AND DELUGE
SHOWER . IF NOISE LEVELS EXCEED 90 DBA FOR AN 8 HOUR (ING 18)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: INGEST OF COMPLETE PRIMER CAN CAUSE IRRIT TO DIGESTIVE
SYS, & POSS OTHER UNKNOWN EFTS. IF LEFT UNTREATED, WEAK, VOMIT,
LOSS OF APPETITE, UNCOORDINATED BODY MOVEMENTS, CONVLS, STUPOR &
POSS COMA. DMG TO BOTH MALE & FEMALE REPRO SYS IS POSS. (ING 8)

Chemical Properties

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:THE ONLY PROPER METH FOR PREPARING PRIMERS FOR
RECLAMATION IS TO SUBJECT PRIMERS (IN SML QTYS) TO SUFFICIENT HEAT
TO RENDER PRIMING MIX INERT. AFTER PRIMERS HAVE BEEN RENDERED INERT
BY METH DESCRIBED, REMAINING SCRAP SHOULD BE RECYCLED/DISP. (ING
17)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.