CFPVQ - VCI-373

  • MSDS: CFPVQ
  • Manufacturer: CORTEC CORP
  • Product Name: VCI-373
  • National Stock Number: 8030-00N080047
Product Identification

Product ID:VCI-373
MSDS Date:02/12/1996
FSC:8030
NIIN:00N080047
MSDS Number: CFPVQ

Responsible Party
CORTEC CORP
4119 WHITE BEAR PARKWAY
ST PAUL, MN 55110
US

Emergency Phone: 612-429-1100; 800-426-7839

Info Phone: 612-429-1100; 800-426-7839

Preparer: MARGARITA KHARSHAN

Cage: 44695

Contractor
THE CORTEC CORPORATION
SAINT PAUL, MN 55110-7634 US

Telephone: 651-429-1100/800-4-CORTEC

Cage: 44695

Ingredients

ETHANOL, 2-BUTOXY-; (ETHYLENE GLYCOL MONOBUTYL ETHER)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 5-10%

OSHA PEL 50 PPM, S

ACGIH TLV: 25 PPM, S


DENATURED ETHYL ALCOHOL; (DENATURED ETHANOL)

Fraction By Weight: <5%

OSHA PEL 200 PPM (MFR)

ACGIH TLV: 200 PPM (MFR)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:RPTD/PRLNG SKIN CONT W/THIS MATL CAN
CAUSE IRRIT. EYE CONT W/THIS MATL CAUSES IRRIT. EXCESSIVE INHAL OF
HIGH VAP CONCS MAY IRRIT UPPER RESP TRACT. IF PROD IS
SPRAYED/ATOMIZED, INHAL OF PARTICLES, MIST S MAY IRRIT UPPER RESP
TRACT & SHOULD BE AVOIDED. INGEST OF THIS PROD IS EXPECTED TO BE
HARMFUL. ANIMAL(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EFTS ON THE CNS, HEMOTOPOIETIC TISSUES, BLOOD,
KIDNEYS & LIVER, ASSOC W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER
(EGBE). (EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO.90-118 .
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. CONSULT MD.
SKIN:WASH AFFECTED AREA W/SOAP & WATER. IF IRRITATION OR RASH
PERSISTS, CONSULT MD. INHAL:REMOVE TO UNCONTAMINATED AREA,
ADMINISTER OXYGEN IF NE CESSARY. GET MEDICAL ATTENTION. INGEST:DO
NOT INDUCE VOMITING. IF VICTIM HAS STOPPED BREATHING BEGIN CPR. GET
IMMEDIATEL MEDICAL ATTENTION.

Fire Fighting

Flash Point:>248F,>120C
Extinguishing Media:WATER, CARBON DIOXIDE OR OTHER DRY CHEMICAL FIRE
FIGHTING AGENTS.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:ABSORB ON SWEEPING COMPOUND OR OTHER ABSORBENT
MATERIAL. KEEP OUT OF STREAMS OR WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID EYE & SKIN CONTACT. AVOID
EXCESSIVE INHALATION OF PRODUCT VAPORS.
Other Precautions:"EMPTY" CNTNRS RETAIN RESIDUE (LIQ &/OR VAP) & CAN BE
DANGEROUS. DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
GRIND/EXPOSE SUCH CNTNRS TO HEAT, FLAME, SPKS/OTHER SOURCES OF
IGNIT; THEY MAY EXPL ODE & CAUSE INJURY/DEATH. DO NOT(SUPDAT)

Exposure Controls

Respiratory Protection:A NIOSH APPROVED RESPIRATOR TO REMOVE VAPORS OR
PARTICLE MISTS WHEN NECESSARY.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:CHEM RESISTANT RUBBER OR PLASTIC GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT:50-62(WT). OTHER PREC:ATTEMPT TO CLEAN SINCE RESIDUE IS DFCLT
TO REMOVE. COMPLETELY DRAIN "EMPTY" DRUMS, PROPERLY BUNG & PROMPTLY
DISP IN AN ENVIRONMENTALLY SAFE MANNER & I/A/W GOVT REGS. RECY CLE
DRUMS ONLY THROUGH QUALIFIED REPROCESSING ORGANIZATIONS.

Chemical Properties

Spec Gravity:1.16-1.21
Appearance and Odor:OLIVE GREEN, VISCOUS LIQUID; SLIGHT AMMONIA ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, ALKALIS & OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID CONTACT W/INCOMPATIBLE MATERIALS.
Hazardous Decomposition Products:OXIDES OF CARBON & NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W EXISTING FEDERAL, STATE & LOCAL
ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.