CFSRN - CARBON DIOXIDE
- MSDS: CFSRN
- Manufacturer: MG INDUSTRIES
- Product Name: CARBON DIOXIDE
- National Stock Number: 6830-00N081594
Product Identification
Product ID:CARBON DIOXIDE
MSDS Date:11/25/1985
FSC:6830
NIIN:00N081594
MSDS Number: CFSRN
Responsible Party
VALLEY FORGE, PA 19482
US
Emergency Phone: 800-345-6351
Info Phone: 800-382-0534
Cage: MGIND
Contractor
Telephone: 215-630-5422
Cage: MGNDU
Ingredients
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
OSHA PEL 5000 PPM
ACGIH TLV: 5000 PPM/30000 STEL
CONTACT CLOSEST SUPPLIER LOCATION OR CALL
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
USE CHECK VALVE/TRAP IN DISCHARGE LINE TO PVNT
RTECS: 9999999ZZ
COMPRESSED GAS ASSOC'S PAMPHLETS P-1, G-6, G-6.1,
RTECS: 9999999ZZ
DRY, WELL-VENTILATED AREA AWAY FROM HEAVILY
RTECS: 9999999ZZ
ARE STORED TO EXCEED 130F (54C). CYLS SHOULD BE
RTECS: 9999999ZZ
KNOCKED OVER. FULL & EMPTY CYLS SHOULD BE
RTECS: 9999999ZZ
FULL CYLS BEING STORED FOR EXCESS PERIODS OF TIME.
RTECS: 9999999ZZ
STRUCTURAL MATLS. MOIST CARBON DIOXIDE IS CORR BY
RTECS: 9999999ZZ
309 & 310 STAINLESS STEELS MAY BE USED AS WELL AS
RTECS: 9999999ZZ
ARE SLIGHLY CORRODED. AT NORMAL TEMPS CARBON
RTECS: 9999999ZZ
COMPRESSED GAS CYLS SHOULD NOT BE REFILLED EXCEPT
RTECS: 9999999ZZ
OF COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED BY
RTECS: 9999999ZZ
OF FEDERAL LAW (49CFR).
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: LOW CONCENTRATIONS
(3-5 MOLAR %) CAUSE INCREASED RESPIRATION & HEADACHE. EIGHT TO 15
MOLAR 1, CONCENTATIONS CAUSE HEADACHES, NAUSEA & VOMITING WHICH MAY
LEAD TO UNCONSCIOUSNESS IF N OT MOVED TO OPEN AIR/GIVEN OXYGEN.
HIGHER CONCENTRATIONS CAUSE RAPID CIRCULATORY INSUFFICIENCY
LEADING(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: TO COMAS & DEATH. TOX PROPERTIES:
CARBON DIOXIDE IS MOST POWERFUL CEREBRAL VASODILATOR KNOWN.
INHALING LG CONCS CAUSES RAPID CIRCULATORY INSUFFICIENCY LEADING TO
COMA & DEATH. CHRONIC HARMFU L EFTS ARE NOT KNOWN FROM INHAL OF LOW
(3-5 MOLAR %) CONCENTRATIONS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO
CARBON DIOXIDE. RESCUE PERS SHOULD BE EQUIPPED W/NIOSH APPRVD SCBA.
INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/POTABLE WATER FOR MINIMUM
OF 15 MINS, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMTS OF
WATER. CALL MD . INHAL: CONSCIOUS PERSONS SHOULD BE ASSISTED TO
UNCONTAMD AREA & INHALE FRESH AIR. QUICK REMOVAL (SUPDAT)
Fire Fighting
Extinguishing Media:NONFLAMMABLE, INERT GAS. MEDIA SUITABLE FOR
SURROUNDING FIRE .
Fire Fighting Procedures:NOT APPLICABLE. USE NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE.
Accidental Release
Spill Release Procedures:EVAC ALL PERS FROM AFFECTED AREA. USE APPROP
PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE PIPING
W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CNTNR/CNTNR
VALVE, CONT CLOSEST S UPPLIER LOCATION/CALL EMER TELEPHONE
NOLISTED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:USE ONLY IN WELL-VENTILATED AREAS.
VALVE PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED
W/VALVE OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK
FOR CYL MOVEMENT. USE PRESS REDUCING REGULATOR WHEN CONNECTING CYL
TO LOWER PRESS (<1500 PSIG) PIPING/SYS. DO NOT HEAT CYL BY ANY
MEANS TO INCR DI SCHARGE RATE OF PROD FROM CYL. (ING 3)
Exposure Controls
Respiratory Protection:NIOSH APPROVED POSITIVE PRESSURE AIR LINE WITH
MASK OR NIOSH APPRVD SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:LOCAL EXHAUST: TO PREVENT ACCUMULATION ABOVE TWA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:FROM CONTAMINATED AREA IS MOST IMPORTANT. UNCONSCIOUS
PERSONS SHOULD BE MOVED TO UNCONTAMINATED AREA, GIVEN
MOUTH-TO-MOUTH RESUSCITATION & SUPPLEMENTAL OXYGEN. ASSURE THAT
VOMITED MATER IAL DOES NOT OBSTRUCT AIRWAY BY USE OF POSITIONAL
DRAINAGE. FURTHER TREATMENT SHOULD BE SYMPTOMATIC & SUPPORTIVE.
Chemical Properties
Boiling Pt:B.P. Text:-109F,-79C
Melt/Freeze Pt:M.P/F.P Text:-70F,-57C
Vapor Pres:856 PSIA
Spec Gravity:1.65 (AIR =1)
Solubility in Water:VERY SOLUBLE
Appearance and Odor:COLORLESS, ODORLESS GAS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:FORMS CARBONIC ACID IN THE PRESENCE OF
WATER.
Hazardous Decomposition Products:CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . DO
NOT ATTEMPT TO DISPOSE OF WASTE/UNUSED QTYS. RETURN IN SHIPPING
CNTNR PROPERLY LBLD, W/ANY VALVE OUTLET PLUGS/CAPS SECURED & VALVE
PROT CAP IN PLACE TO SUPPLIER. FOR EMER DISP ASSISTANCE,(ING 2)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.