CGCTS - COLDPATCH

Product Identification

Product ID:COLDPATCH
MSDS Date:01/12/1997
FSC:9350
NIIN:00N082367
MSDS Number: CGCTS

Responsible Party
NORTH AMERICAN REFRACTORIES
1228 EUCLID AVE
CLEVELAND, OH 44115-1809
US

Emergency Phone: 814-234-7981;814-236-3890

Info Phone: 814-234-7981

Cage: 86653

Contractor
NORTH AMERICAN REFRACTORIES COMPANY
CLEVELAND, OH 44115-1809 US

Telephone: 814-234-7981/814-234-3890

Cage: 86653

Ingredients

SILICA, CRYSTALLINE - QUARTZ CONTAINING INGS 2 & 3

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 10-30%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.05 MG/M3 RDUST


SILICA, CRYSTALLINE - TRIDYMITE

CAS: 15468-32-3

RTECS: VV7335000

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.05 MG/M3 RDUST


ALUMINUM SILICATE

CAS: 1302-93-8

Fraction By Weight: 30-60%

OSHA PEL N/K

ACGIH TLV: N/K


HYDROUS ALUMINA SILICATE

CAS: 1302-87-0

Fraction By Weight: 30-60%

OSHA PEL N/K

ACGIH TLV: N/K


SILICIC ACID (H*2SIO*3), DISODIUM SALT; (SODIUM

CAS: 6834-92-0

RTECS: VV9275000

Fraction By Weight: 10-30%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CRYSTALLINE SILICA: INHAL OF
DUST CONTAINING CRYSTALLINE SILICA MAY CONRIBUTE TO PRE-EXISTING
PULM DISEASES SUCH AS ASTHMA & LUNG DISORDERS ASSOC W/SMKNG OF
TOCACCO. SODIUM SILICATE: MAY CUASE SKIN & EYE IRRITATION.
CHRONIC: CRYSTALLINE SILICA: CHRONIC OVEREXPOSURE TO DUST
CONTAINING RESPIRABLE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE SILICA-QUARTZ, CRISTOBALITE
& TRIDYMITE: IARC MONO, VOL 68, 1997: GROUP 1. NTP 7TH ANNUAL RPT
ON (SUPDAT)
Effects of Overexposure:HLTH HAZ: SIZED CRYSTALLINE DILICA (QUARTZ,
CRISTOBALITE, & TRIDYMITE) CAN CAUSE DELAYED LUNG INJURY. POINT OF
ATTACK: RESP SYS & LUNG. SOME RECENT ANIMAL STUDIES HAVE CAUSED
IARC TO CATEGORIZE CRYSTA LLINE SILICA AS 2A CARCIN. A 2A CARCIN IS
ONE WHICH (1) THERE IS SUFFICIENT EVIDENCE FOR CARCINOGENICITY TO
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . SKIN: WASH THOROUGHLY WITH SOAP
AND WATER. INHALATION: REMOVE TO FRESH AIR. EYES: FLUSH WITH WATER
FOR AT LEAST 15 MINUTES AND GET MEDICAL HELP.

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:NON-FLAMMABLE. MEDIA SUITABLE FOR SURROUNDING FIRE
.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:AVOID GENERATING DUST EXPOSURE DURING CLEANUP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID HIGH TEMPERATURE STORAGE.
Other Precautions:DUST CREATED DURING DEMOLITION OF USED PRODUCT MAY
CONTAIN CRYSTALLINE SILICA.

Exposure Controls

Respiratory Protection:NIOSH APPROVED DUST TYPE FOR EXPOSURE ABOVE TLV.
Ventilation:SUFFICIENT VENTILATION SHOULD BE USED TO INSURE EXPOSURES
BELOW THE TLV/PEL.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:HYGIENE MONITORING SHOULD BE DONE TO INSURE
PROPER EMPLOYEE PROTECTION DURING TEAROUT.
Supplemental Safety and Health
EXPLAN OF CARCIN: CARCIN, 1994: ANTICIPATED TO BE CARCINOGEN. EFTS OF
OVEREXP: EXPERIMENTAL ANIMALS. (2) THERE IS LIMITED EVIDENCE OF
CARCINOGENICITY TO HUMANS.

Chemical Properties

pH:9-10.9
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NOT AVAILABLE
Appearance and Odor:TAN, FINE-GRAINED, WET MIXTURE, ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:THIS PRODUCT IS STABLE AND NON-REACTIVE.
Hazardous Decomposition Products:CRYSTALLINE SILICA LEVELS IN USED
REFRACTORIES MAY BE HIGHER/LOWER THAN AS-SHIPPED DEPENDING ON
SERVICE CNDTNS.

Disposal

Waste Disposal Methods:DISPOSE OF MATERIAL ACCORDING TO LOCAL, STATE OR
FEDERAL REGULATIONS AND AS FINAL USED CONDITION OF THE PRODUCT
DICTATES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.