CGFNC - 850 6248 ANACOMP AUTOEXCEL(R) FIXER, 1 GALLON READY-TO-USE

  • MSDS: CGFNC
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: 850 6248 ANACOMP AUTOEXCEL(R) FIXER, 1 GALLON READY-TO-USE
  • National Stock Number: 6750-00D007239
Product Identification

Product ID:850 6248 ANACOMP AUTOEXCEL(R) FIXER, 1 GALLON READY-TO-USE
MSDS Date:10/29/1997
FSC:6750
NIIN:00D007239
Kit Part:Y
MSDS Number: CGFNC

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 800- 242-2424

Cage: 19139

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 80-90%


AMMONIUM THIOSULFATE

CAS: 7783-18-8

RTECS: XN6465000

Fraction By Weight: 10-15%


SODIUM ACETATE

CAS: 127-09-3

RTECS: AJ4300010

Fraction By Weight: 1-5%


AMMONIUM BISULFITE (CERCLA)

CAS: 10192-30-0

RTECS: WT3595000

Fraction By Weight: <1%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


AMMONIUM ACETATE (CERCLA)

CAS: 631-61-8

RTECS: AF3675000

Fraction By Weight: <1%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXPECTED TO BE A LOW HAZARD FOR
RECOMMENDED HANDLING.IN CONTACT W/STRONG ACIDS/IF HEATED SULFITES
MAY LIBERATE SULFUR DIOXIDE GAS WHICH IRRIT RESP TRACT.SOME
ASTHMATICS/HYPERSENS INDIVIDUALS MAY EXPERIENCE DIFFI
BREATH.EYE:NO SPEC HAZ KNOWN.MAY CAUSE TRANSIENT IRRIT.SKIN:MATL
HAS LOW POT TO CAUSE (SIGN/SYMPTOMS)
Explanation of Carcinogenicity:PER MSDS:CARCINOGENICITY
CLASSIFICATION:IARC/ACGIH/NTP/OSHA:NONE.
Effects of Overexposure:HEALTH:ALLERGIC SKIN REACTIONS;HOWEVER CASES OF
HUMAN SKIN SENSITIZATION HAVE BEEN REPORTED.INGEST:MAY BE HARMFUL
IF SWALLOWED.SOME ASTHMATICS OR SULFITE-SENS INDIVIDUALS MAY
EXPERIENCE WHEEZING,CHEST TIGHTNESS,STOMACH
UPSET,HIVES,FAINTNESS,WEAKNESS & DIARRHEA.
Medical Cond Aggravated by Exposure:SOME ASTHMATICS OR
SULFITE-SENSITIVE INDIVIDUALS MAY EXPERIENCE WHEEZING,CHEST
TIGHTNESS,STOMACH UPSET,HIVES,FAINTNESS,WEAKNESS,DIARR,DIFFICULT
BREATHING.

First Aid

First Aid:INHAL:IF SYMPTOMATIC MOVE TO FRESH AIR.TREAT
SYMPTOMATICALLY.GET MED ATTN IF SYMPTOMS PERSIST. EYES:ANY MATL
THAT CONTACTS EYE SHOULD BE WASHED OUT IMMED W/WATER. GET MED ATTN
IF SYMPTOMS OCCUR. SKIN: WASH W/SOAP & WATER.GET MED ATTN IF
SYMPTOMS OCCUR. INGEST:DRINK 1-2 GLASSES OF WATER.SEEK MED
ATTN.NEVER GIVE ANYTHING BY MOUTH IF UNCONSCIOUS.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Autoignition Temp:Autoignition Temp Text:NP
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH TO SEWER W/LG AMTS OF WATER.OTHERWISE
ABSORB W/VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN
CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO REMOVE
RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID BREATHING MIST/VAPO.AVOID
CONTACT W/EYES & PROL/REP CONTACT W/SKIN.USE W/ADEQUATE VENTI.KEEP
CONTAINER CLSD.KEEP FRM CONTACT W/OXID/INCOMPAT SUB
Other Precautions:PROPERTIES:MOD BIOCHEM OXY DEMAND,MAY CAUSE OXY
DEPLETION IN AQU SYS,MOD POT TO AFFECT AQUATIC ORGANISMS,LOW POT TO
AFFECT 2ND WASTE TREAT MICROBIAL METABOLISM,LOW POT TO AFFECT
GERM/EARLY GROWTH OF S OME PLANTS,LOW POT TO BIOCONCEN.(SUPPLE)

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS, GOGGLES.
Other Protective Equipment:EYEBATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HNDLG.GOOD INDUSTRIAL HYG
PRACTICE TO MIN EYE/SKIN CONTACT.
Supplemental Safety and Health
OTHER PRECAUT:DILUTED W/LG AMT OF WATER MATL RELEASED DIR/INDIR INTO
ENVIRO NOT EXPECTED TO HAVE SIGNIFICANT IMPACT.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.07
pH:5.1
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, VINEGAR ODOR
Percent Volatiles by Volume:80-90
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS,BASES,STRONG OXIDIZING AGENTS,SODIUM
HYPOCHLORITE(BLEACH).CONTACT W/BASE LIBERATES FLAMM MATL.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NITROGEN OXIDES (NOX),SULFUR DIOXIDE,
AMMONIA, CHLORAMINE.

Disposal

Waste Disposal Methods:DISCHARGE/TREATMENT/DISPOSAL MAY BE SUBJECT TO
NATIONAL/STATE/LOCAL LAWS. FLUSH TO SEWER W/LG AMTS OF WATER. CHEM
SUBJ TO REPORTING REQMTS OF SEC 313 TITLE III SARA/40CFR372:NONE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.