CGMGD - WESCODYNE
- MSDS: CGMGD
- Manufacturer: CALGON VESTAL LABORATORIES
- Product Name: WESCODYNE
- National Stock Number: 6840-00-526-1129
Product Identification
Product ID:WESCODYNE
MSDS Date:05/15/1997
FSC:6840
NIIN:00-526-1129
MSDS Number: CGMGD
Responsible Party
SAINT LOUIS, MO 63110
US
Emergency Phone: 314-535-1810
Info Phone: 314-862-2000
Preparer: M. EBERS
Cage: 19410
Contractor
Telephone: 800-548-4873 / 314-535-1810
Cage: 19410
Ingredients
IODINE
CAS: 7553-56-2
RTECS: NN1575000
Fraction By Weight: 1.75%
OSHA PEL 0.1 PPM, C
ACGIH TLV: 0.1 PPM, C
PHOSPHORIC ACID (SARA 313) (CERCLA)
CAS: 7664-38-2
RTECS: TB6300000
Fraction By Weight: 16%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 3 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CAUSES IRREVERSIBLE EYE DAMAGE.
SKIN: MAY CAUSE SKIN IRRITATION. ALLERGIC REACTIONS ARE POSSIBLE.
PROLONGED ABSORPTION MAY PRODUCE "IODISM" WHICH IS MANIFESTED BY
SKIN RASH, RUNNING NOSE, HEADAC HE AND IRRITATION OF MUCOUS
MEMBRANES.
Explanation of Carcinogenicity:NOT LISTED AS A CARCINOGEN BY NTP, IARC
OR OSHA.
Effects of Overexposure:INHALATION: INHALATION OF HIGH CONCENTRATIONS
OF IODINE CAUSES IRRITATION OF RESPIRATORY TRACT. INGESTION:
INGESTION OF LARGE QUANTITIES OF IODINE CAUSES ABDOMINAL PAIN,
NAUSEA, VOMITING AND DIARRHEA. CHRONIC HEALTH HAZARDS: NONE KNOWN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: IMMED FLUSH EYES W/PLENTY OF WATER FOR AT LEAST 15 MIN.
CALL MD. SKIN: IMMED FLUSH SKIN W/PLENTY OF WATER FOR AT LEAST 15
MIN. CALL MD. INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE
ARTIFIC IAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN.
CALL MD. INGEST: IF SWALLOWED, DO NOT INDUCE VOMIT. GIVE LARGE QTYS
OF WATER. CALL MD IMMED. NEVER GIVE ANYTHING BY MOUTH TO AN UNCON
PERSON.
Fire Fighting
Extinguishing Media:USE WATER, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:WEAR POSITIVE-PRESSURE SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES OF IODINE IN A FIRE
SITUATION.
Accidental Release
Spill Release Procedures:CONTAIN SPILLAGE AND SOAK UP W/INERT ABSORBENT
AND SCOOP INTO A COVERED CONTAINER FOR DISPOSAL. NOTIFICATION OF
NRC (800-424-8802) MAY BE REQUIRED. IT IS RECOMMENDED THAT EACH
USER ESTABLISH A SPILL P REVENTION, CONTROL & COUNTERMEASURE PLAN
(SPCC).
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
FOOD AND FEED PRODUCTS. STORE IN A COOL, DRY LOCATION AWAY FROM
ALKALIES AND REDUCING AGENTS.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:NOT NORMALLY REQUIRED.
Ventilation:GENERAL LOCAL EXHAUST VENT AS NECESSARY TO CONTROL ANY
RELEASE TO ENVIRONMENT IN EXCESS OF SPECIFIED THRESHOLD LIMIT.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:WEAR ANY OTHER PROTECTIVE BODY EQUIPMENT TO
PREVENT SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE.
Chemical Properties
HCC:N1
Spec Gravity:1.13 (H2O=1)
pH:1.7
Solubility in Water:100% SOLUBLE
Appearance and Odor:DARK LIQUID, MILD IODINE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
ALKALIES AND REDUCING AGENTS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:MAY EMIT IODINE VAPORS IN HIGH
TEMPERATURE SITUATIONS.
Disposal
Waste Disposal Methods:FEDERAL, STATE AND LOCAL DISPOSAL LAWS AND
REGULATIONS WILL DETERMINE THE PROPER WASTE DISPOSAL PROCEDURE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.