CGNVD - SIFCO SELECTRON SOLUTION AERONIKL 575, 70572705

  • MSDS: CGNVD
  • Manufacturer: SIFCO SELECTIVE PLATING
  • Product Name: SIFCO SELECTRON SOLUTION AERONIKL 575, 70572705
  • National Stock Number: 6850-00N070089
Product Identification

Product ID:SIFCO SELECTRON SOLUTION AERONIKL 575, 70572705
MSDS Date:06/25/1997
FSC:6850
NIIN:00N070089
MSDS Number: CGNVD

Responsible Party
SIFCO SELECTIVE PLATING
5708 SCHAAF RD
CLEVELAND, OH 44131-1394
US

Emergency Phone: 216-881-8600; 216-557-7345

Info Phone: 216-524-0099; 216-524-6331

Cage: DO645

Contractor
SIFCO SELECTIVE PLATING, DIV OF SIFCO INDUSTRIES INC
CLEVELAND, OH 44131-1394 US

Telephone: 216-524-0099

Cage: DO645

Ingredients

NICKEL (SARA 313) (CERCLA)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 5-10%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


SULFAMIC ACID

CAS: 5329-14-6

RTECS: WO5950000

Fraction By Weight: 20-30%

OSHA PEL N/K

ACGIH TLV: N/K


BORIC ACID

CAS: 10043-35-3

RTECS: ED4550000

Fraction By Weight: 1-5%

OSHA PEL 10 MG BORATES/M3

ACGIH TLV: 5 MG BORATES/M3


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 55-84%

OSHA PEL N/K

ACGIH TLV: N/K


HOLD

RTECS: 9999999ZZ


IMMED FLUSH W/PLENTY OF WATER FOR AT

RTECS: 9999999ZZ


REMOVE

RTECS: 9999999ZZ


TIGHT CLTHG, COVER W/BLANKET. IF NOT BRTHG, GIVE

RTECS: 9999999ZZ


NOT INDUCE VOMIT, UNLESS ADVISED BY EMS. GIVE VICTIM

RTECS: 9999999ZZ


EGGS. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS

RTECS: 9999999ZZ


(PPE). CAREFULLY MOP UP/VACUUM SPILL & TRIPLE

RTECS: 9999999ZZ


REPORTABLE QTY (RQ) REQUIRES NOTIFICATION OF PROPER

RTECS: 9999999ZZ


CONTAM MAY AFFECT DISP REQS. THE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: SKIN, EYES, NASAL
CAVITY, LUNGS, KIDNEYS & LIVER. EYES: CAUSES IRRIT, BURNS POSS.
SKIN: MAY CAUSE IRRIT, SENSIT, & ALLERGIC RXN (NICKEL RASH). INHAL:
VAP/MIST MAY BE HARMFUL IF INHALED. MAY CAUSE SNEEZING, NASAL
DISCHARGE, COUGHING, HDCH, DIZZ, NAUS, FATIGUE/DFCLTY IN BRTHG.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL: IARC MONO, VOL 49, PG 257, 1990:
GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994: ANTIC TO BE CARCIN.
ANIMAL:LUNG.
Effects of Overexposure:HLTH HAZ: IRRITATING TO EYES, NOSE, THROAT &
LUNGS. INGEST: HARMFUL IF SWALLOWED. CAN IRRITATE MOUTH, THROAT, &
STOM. MAY CAUSE LIVER DMG W/JAUN, KIDNEY & GI DMG. CHRONIC:
PRLNG/RPTD EXPOS MAY CAUSE D MG TO SKIN, EYES, RESP SYS & TEETH.
MAYCAUSE SEV & DELAYED HLTH EFTS SUCH AS INFLAMM OF LUNGS & CHEM
BRONCH. (SUP DAT)
Medical Cond Aggravated by Exposure:PREEXISTING SKIN AND EYE
CONDITIONS; RESPIRATORY SYSTEM DISORDERS; PREEXISTING SENSITIZATION
TO NICKEL.

First Aid

First Aid:FIRST AID PROVIDERS MUST TAKE PROPER PREC FOR THEIR OWN SFTY
BEFORE ENTERING CONTAM AREAS TO ASSIST ACCIDENT VICTIMS & HNDLG
THEIR CONTAM CLTHG & EQUIP. ANOTHER PERSON SHOULD IMMED CALL EMER
MED SERVI CE, 911-OPERATOR, HOSPITAL, MD, OPHTHALMOLOGIST/POIS CTL
CTR, AS APPLIC. GIVE THE FOLLOWING INFO: LOCATION OF ACCIDENT, YOUR
PHONE NUMBER, DESCRIPTION OF ACCIDENT, NAME OF CHEM AGENT & PROD,
(SUP DAT)

Fire Fighting

Flash Point:NONE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:ALL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . STRUCTURAL FIRE FIGHTERS' PROTECTIVE CLOTHING MAY NOT
PROVIDE ADEQUATE PROTECTION.
Unusual Fire/Explosion Hazard:CONTRS CAN BUILD UP PRESS & BURST IF
EXPOS TO HEAT (FIRE). CONTACT W/METALS MAY FORM FLAM HYDROGEN GAS.
WATER RUNOFF CAN CAUSE ENVIRON DMG. DIKE AREA FOR DISP.

Accidental Release

Spill Release Procedures:DO NOT TOUCH/WALK THRU SPILLED MATL. ISOLATE
HAZ AREA & KEEP PEOPLE AWAY. NOTIFY YOUR FACILITY EMER COORDINATOR.
ELIM ALL SOURCES OF IGNIT. PROVIDE MAX VENT. DO NOT RELEASE INTO
SOIL, SEWERS/NATRL BOD IES OF WATER. WEAR PROPER PERS PROT EQUIP
(ING 11)
Neutralizing Agent:SODA ASH AND CRUSHED LIMESTONE.

Handling

Handling and Storage Precautions:USE "BUDDY SYSTEM" WHEN WORKING
W/CHEMICALS. DO NOT GET IN EYES, ON SKIN, ON CLOTHING. DO NOT
BREATHE VAPOR, MIST/GAS. USE W/ADEQUATE VENTILATION.
Other Precautions:TRIPLE RINSE CONTR CLEAN BEFORE DISCARDING. PUT
NOTHING ELSE IN THIS CONTR. KEEP CONTR TIGHTLY CLOSED IN UPRIGHT
POSITION. STORE AT 60-90F AWAY FROM INCOMPATIBLE MATLS & PHYSICAL
HAZARDS. DO NOT REMOV E/DEFACE CONTR LABELS.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS ARE NOT FEASIBLE, THE
RESPIRATORY PROTECTION PROGRAMS MUST COMPLY WITH OSHA'S 29 CFR
1910.134, 30 CFR 11 AND ANSI Z88.2 REQUIREMENTS.
Ventilation:LOCAL EXHAUST VENTILATION IS REQUIRED TO MEET THE
PERMISSIBLE EXPOSURE LIMITS (PEL) DURING THE USE OF THIS PRODUCT.
Protective Gloves:NITRILE, NEOPRENE, VINYL, LATEX GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYEWASH & DELUGE
SHOWER . IMPERVIOUS BOOTS, APRON, PROT CLOTHING AS REQUIRED BY JOB
CNDTNS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. DO NOT WEAR
CONTACT LENSES.
Supplemental Safety and Health
PH: 1.3-1.7. EFTS OF OVEREXP: PRLNG EXPOS TO NICKEL & NICKEL CMPDS MAY
INCR POSS OF NASAL SINUS & LUNG CANCER. FIRST AID PROC: NUMBER &
CNDTN OF CASUALTIES, WHAT IS BEING DONE FOR VICTIMS. STAY ON PHO NE
UNTIL OTHER PARTY HANGS UP! REMOVE VICTIM FROM CONTAM AREA TO
CLEAN, QUIET, VENTILATED AREA. (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:<32F,<0C
Spec Gravity:1.315-1.335
pH:SUPDAT
Evaporation Rate & Reference:<1 (ETHYL ETHER=1)
Solubility in Water:COMPLETE
Appearance and Odor:DARK GREEN LIQUID; SLIGHT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH REACTIVE METALS, STRONG BASES, OXIDIZERS, CYANIDES,
SULFIDES.
Stability Condition to Avoid:STABLE UNDER NORMAL AMBIENT CONDITIONS.
Hazardous Decomposition Products:H*2, SO*X, NO*X, NI, B.

Disposal

Waste Disposal Methods:SHIP TO APPROVED TREATMENT/DISP FACILITY. DISP
OF ACCORDING TO LOC, STATE, & FED REGULATIONS. EPA WASTE I.D.
NUMBER: D002. FOLLOW APPLICABLE REGS FOR DISP OF EMPTY CONTRS &
RINSATE. DISP INFORMATION A PPLIES TO MATL AS MANUFACTURED. (ING
13)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their