CGRYZ - QA INSPECT CLEANER, S00743

  • MSDS: CGRYZ
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: QA INSPECT CLEANER, S00743
  • National Stock Number: 6810-00N084002
Product Identification

Product ID:QA INSPECT CLEANER, S00743
MSDS Date:09/01/1996
FSC:6810
NIIN:00N084002
MSDS Number: CGRYZ

Responsible Party
SHERWIN-WILLIAMS CO
31500 SOLON RD
SOLON, OH 44139
US

Emergency Phone: 216-566-2917

Info Phone: 800-777-2966

Cage: DO642

Contractor
SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
BEDFORD HEIGHTS, OH 44146 US

Telephone: 216-292-7400 OR 216-595-8634

Cage: 09800

Ingredients

760.0

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 13%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9495


760.0

CAS: 106-97-8

RTECS: EJ4200000

Fraction By Weight: 12%

OSHA PEL 800 PPM

ACGIH TLV: 800 PPM; 9495


ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (SARA

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 75%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM/450STEL;9495

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


VOLATILE ORGANIC CONTENT AS A PERCENT BY WEIGHT PER BAAQMD

RTECS: 9999999VO


2.00

RTECS: 9999999VO


ASSOCIATED REPEATED AND PROLONGED OVEREXPOSURE TO

RTECS: 9999999ZZ


WASTE FROM 00740 QA INSPECTION

RTECS: 9999999ZZ


HAZARDOUS DUE TO THE PRESENCE OF 1,1,1-

RTECS: 9999999ZZ


DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND

RTECS: 9999999ZZ


RESPIRATOR APPROVED BY NIOSH FOR DUST WHICH MAY

RTECS: 9999999ZZ


CLASSIFIED AS NUISANCE PARTICULATES (LISTED "AS DUST"

RTECS: 9999999ZZ


ONLY DURING SANDING/ABRADING OF THE DRIED FILM. IF

RTECS: 9999999ZZ


APPLIC LIM FOR NUISANCE DUSTS ARE ACGIH TLV 10 MG/M3

RTECS: 9999999ZZ


OSHA PEL 15 MG/M3 (TOTAL DUST), 5 MG/M3 (RESPIRABLE

RTECS: 9999999ZZ


THE EXPOSURE TO MATERIALS IN SECTION 2 IS MAINTAINED

RTECS: 9999999ZZ


STANDARDS 1910.94, 1910.107, 1910.108.

RTECS: 9999999ZZ


CONSULT NFPA CODE. USE APPRVD BONDING &

RTECS: 9999999ZZ


INCINERATE OR EXPOSE TO TEMPERATURE ABOVE 120F. HEAT

RTECS: 9999999ZZ


HOT H*2O, & OTHER HEAT SOURCES COULD CAUSE CNTNR TO

RTECS: 9999999ZZ


OF CHILDREN. INTENTIONAL MISUSE BY DELIBERATELY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRITATION OF EYES, SKIN AND
RESPIRATORY SYSTEM. MAY CAUSE NERVOUS SYSTEM DEPRESSION. SIGNS AND
SYMPTOMS OF OVEREXPOSURE: HEADACHE, DIZZINESS, NAUSEA, (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:& LOSS OF COORDINATION ARE INDICATIONS
OF EXCESSIVE EXPOS TO VAPS/SPRAY MISTS. REDNESS & ITCHING/BURNING
SENSATION MAY INDICATE EYE/EXCESSIVE SKIN EXPOS. CHRONIC:PRLNG
OVEREXP TO SOLV ING IN SECTION 2 MAY CAUSE ADVERSE EFTS TO
THELIVER, URINARY, BLOOD FORMING & REPRO SYS. METHYL ETHYL KETONE
MAY (SUPDAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL:IF AFFECTED, REMOVE FOR EXPOS. RESTORE BRTHG. KEEP WARM
& QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & H*2O. REMOVE
CONTAMD CLTHG & LAUNDER BEFORE RE-USE. EYE:FLUSH EYES W/LRG AMTS OF
H*2O FOR AT LEAST 15 MIN. GET MED ATTN. INGEST:NEVER GIVE ANYTHING
BY MOUTH TO AN UNCON PERSON. DO NOT INDUCE VOMIT. GIVE SEVERAL
GLASSES OF H*2O. SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0.9%
Upper Limits:12.0%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . IF
H*2O IS USED, FOG NOZZLES ARE PREF. H*2O MAY BE USED TO COOL CLSD
CNTNRS TO PRVNT PRESS BUILD-UP & (SUPDAT)
Unusual Fire/Explosion Hazard:CLSD CNTNRS MAY EXPLODE (DUE TO THE
BUILD-UP OF PRESS) WHEN EXPOSED TO EXTREME HEAT. ISOLATE FROM HEAT,
ELEC EQUIP, SPARKS & OPEN FLAMES. APPLICATION (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CONTENTS ARE EXTREMELY FLAMMABLE. KEEP
AWAY FROM HEAT, SPARKS, AND OPEN FLAME. VAPORS WILL ACCUMULATE
READILY & MAY IGNITE EXPLOSIVELY.
Other Precautions:VAP WILL ACCUM READILY & MAY IGNITE EXPLOSIVELY.
DURING USE & UNTIL ALL VAPS ARE GONE: KEEP AREA VENT- DO NOT
SMOKE-EXTING ALL FLAMES, PILOT LIGHTS, & HEATER-TURN OFF STOVES,
ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF IGNITION. (ING 17)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR A PROPERLY FITTED ORG VAP/PARTICULATE
RESP APPRVD BY NIOSH FOR PROT AGAINST MATS IN SECTION 2. WHEN
SANDING/ABRADING THE DRIED FI LM, WEAR A DUST/MIST (ING 10)
Ventilation:USE W/ONLY ADEQ VENT. AVOID BRTHG VAP & SPRAY MIST. AVOID
CNTCT W/SKIN & EYES. THESE COATINGS MAY CNTN MATLS (ING 11)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: POSS AUTOIGNITION/EXPLOSION WHEN EXPOSED TO EXTREME
HEAT. EXPLO HAZ:TO HOT SURF REQUIRES SPECIAL PREC. DURING EMER
CNDTS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE
I MMEDIATELY APPARENT. OBTAIN MED ATTN. EFTS OF OVEREXP:INCR THE
NERVOUS SYS EFFECTS OF OTHER SOLV. RPTS HAVE (ING 6)

Chemical Properties

Boiling Pt:B.P. Text:<395F,<202C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:0.96
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS LISTED IN ING SECTION.

Disposal

Waste Disposal Methods:WASTE FROM THESE PRODS MAY BE HAZ AS DEFINED
UNDER THE RCRA 40 CFR 26. WASTE MUST BE TESTED FOR IGNITABILITY TO
DETERM THE APPLIC EPA HAZ WASTE NUMBERS. WASTE FROM PRODS CNTNG
METHYL ETHYL KETONE MAY ALSO REQ TESTING FOR EXTRACTABILITY. (ING
7)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.