CGVDN - OXYGEN

  • MSDS: CGVDN
  • Manufacturer: SCOTT SPECIALTY GASES
  • Product Name: OXYGEN
  • National Stock Number: 6830-00N084896
Product Identification

Product ID:OXYGEN
MSDS Date:01/10/1997
FSC:6830
NIIN:00N084896
MSDS Number: CGVDN

Responsible Party
SCOTT SPECIALTY GASES
1290 COMBERMERE ST
TROY, MI 48083
US

Emergency Phone: 810-589-2950

Info Phone: 810-589-2950

Cage: 51829

Contractor
SCOTT SPECIALTY GASES INC
PLUMSTEADVILLE, PA 18949 US

Telephone: 215-766-8861

Cage: 51829

Ingredients

OXYGEN

CAS: 7782-44-7

RTECS: RS2060000

Fraction By Weight: >99%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EXTENDED EXPOS TO OXYGEN AT
HIGHER PRESS MAY BE HAZ. A VARIETY OF CNS EFTS MAY RSLT FROM BRTHG
OXYGEN GREATER THAN 2 ATM. SYMPS INCLUDE DIZZ, IMPAIRED COORD,
VISUAL & HEARING DISTURBS & SEIZURE S. CAN CAUSE FROSTBITE & BURNS
TO SKIN & EYES. CHRONIC: PRLNG BRTHG OF VERY COLD ATMS CAN CAUSE
LUNG (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: DMG. PRLNG EXPOS TO COLD AREAS CAN
RSLT IN HYPOTHERMIA.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INHAL: IMMED REMOVE VICTIM TO FRESH AIR. IF BRTHG HAS
STOPPED, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN. EYES:
REMOVE VICTIM FROM SOURCE OF CONT. RINSE IMMED W/PLENTY OF WATER
FOR AT LEAST 15 MI NS & SEEK MED ADVICE. SKIN: DO NOT APPLY DIRECT
HEAT. DO NOT RUB FROZEN AREA. FLUSH AFFECTED AREA W/TEPID WATER.
INGEST: CALL MD IMMED . IN THE EVENT OF EXPOS, CONT MD. NOTE TO MD:
NONE.

Fire Fighting

Flash Point:NON-FLAMMABLE
Lower Limits:NON-FLAMM
Upper Limits:NON-FLAMM
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
FIRE.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
KEEP FIRE-EXPOSED CYLINDERS COOL W/WATER SPRAY. IF POSSIBLE, STOP
PROD FLOW. MOVE CONTR FROM FIRE AREA IF POSS.
Unusual Fire/Explosion Hazard:CYLINDER RUPTURE MAY OCCUR UNDER FIRE
CONDITIONS. HIGH OXIDIZING ATMOSPHERE INCREASES THE LIKELIHOOD OF
FIRES. OXYGEN VIGOROUSLY SUPPORTS COMBUSTION.

Accidental Release

Spill Release Procedures:EVACUATE AND VENTILATE AREA. SHUT OFF SOURCE
IF POSSIBLE AND REMOVE SOURCE OF HEAT. SPECIAL EQUIPMENT: NONE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:SECURE CYL WHEN USING TO PROTECT FROM
FALLING. USE SUITABLE HAND TRUCK TO MOVE CYLS. USE ONLY OXYGEN
CLEANED EQUIP. AVOID OILS & GREASES.
Other Precautions:OXYGEN REACTS VIOLENTLY W/HYDROCARBONS PARTICULARLY
AT HIGH PRESS. STORE IN WELL-VENTILATED AREAS AWAY FROM COMBUSTS.
KEEP VALVE PROT CAP ON CYLS WHEN NOT IN USE. PROTECT CONTRS FROM
PHYSICAL DMG. DO NOT DEFACE CYLS/LABELS. (SUP DAT)

Exposure Controls

Respiratory Protection:IN CASE OF LEAKAGE, USE NIOSH APPROVED SCBA.
Ventilation:PROVIDE ADEQUATE GENERAL AND LOCAL EXHAUST VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYEWASH AND DELUGE
SHOWER . WEAR SAFETY SHOES WHEN HANDLING CYLINDERS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC: CYLS SHOULD BE REFILLED BY QUALIFIED PRODUCERS OF
COMPRESSED GAS. SHIPMENT OF COMPRESSED GAS CYL WHICH HAS NOT BEEN
FILLED BY OWNER/WITH HIS WRITTEN CONSENT IS A VIOLATION OF FED LAW
(49 C FR).

Chemical Properties

Boiling Pt:B.P. Text:-297F,-183C
Vapor Density:1.105
Spec Gravity:GAS (H*2O=1)
Evaporation Rate & Reference:GAS
Solubility in Water:4.89 CM3/100 CM3
Appearance and Odor:COLORLESS, ODORLESS GAS

Stability

Stability Indicator/Materials to Avoid:YES
REACTS VIOLENTLY WITH PHOSPHINE, HYDRAZINE, ETHERS, ALCOHOLS, HYDROGEN
SULFIDE, AND HYDROCARBONS.
Stability Condition to Avoid:STORAGE IN POORLY VENTILATED AREAS.
STORAGE NEAR A HEAT SOURCE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:NON-RETURNABLE CYLINDERS MUST NOT BE REFILLED.
DISPOSE OF NON-REFILLABLE CYLINDERS I/A/W FED, STATE, & LOC REGS.
ALLOW GAS TO DISCHARGE AT MOD RATE. RETURN CYLINDERS TO SUPPLIER
W/ANY VALVE OUTLET PLU GS/CAPS SECURE & VALVE PROT CAP IN PLACE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.