CGWCH - OCTREOSCAN
- MSDS: CGWCH
- Manufacturer: MALLINCKRODT MEDICAL INC
- Product Name: OCTREOSCAN
- National Stock Number: 6505-00F056011
Product Identification
Product ID:OCTREOSCAN
MSDS Date:01/01/1997
FSC:6505
NIIN:00F056011
MSDS Number: CGWCH
Responsible Party
MARYLAND HEIGHTS, MO 63043-3421
US
Emergency Phone: 314-770-7800
Info Phone: 314-770-7800/314-895-2000
Cage: FO650
Contractor
Telephone: 314-770-7800/314-895-2000
Cage: FO650
Ingredients
PENETREOTIDE
CAS: 138661-02-6
Fraction By Weight: 0.06%
INOSITOL *98-1*
CAS: 87-89-8
RTECS: NM7520800
Fraction By Weight: 57.8%
SODIUM CITRATE
CAS: 6132-04-3
Fraction By Weight: 28.4%
2,5-DIHYDROXYBENZOIC ACID
CAS: 490-79-9
RTECS: LY3850000
Fraction By Weight: 11.6%
CITRIC ACID, MONOHYDRATE
CAS: 5949-29-1
RTECS: GE7810000
Fraction By Weight: 2.1%
INDIUM CHLORIDE IN-111
CAS: 50800-85-6
Fraction By Weight: <1%
HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID
CAS: 7647-01-0
RTECS: MW4025000
Fraction By Weight: <1%
OSHA PEL 5 PPM
ACGIH TLV: C 11 MG/CUM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
FERRIC CHLORIDE
CAS: 7705-08-0
RTECS: LJ9100000
Fraction By Weight: <1%
ACGIH TLV: 1 MG/CUM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: >99%
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE ASYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS/TISSUES. EYES: MAY
CAUSE MECHANICAL IRRITATION. CHRONIC RADIATION EXPOSURE (CANCER,
LEUKEMIA, GENETIC & TERATOGENIC EFF ECT) INVOLVE LEVELS OF
RADIATION EXPOSURE WHICH ARE MUCH HIGHER THAN THOSE PERMITTED.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION.
First Aid
First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. ALWAYS BLOT DRY. DON'T
ABRADE. EYES: WASH W/WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN
ALL CASES.
Fire Fighting
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH APPROVED
SCBA W/FULL FACEPIECE OPERATED IN THE PRESSURE DEMAND/OTHER
POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:NON-FLAMMABLE. SOLUTION MAY EMIT
RADIOACTIVE FUMES CONTAINING IN-111.
Accidental Release
Spill Release Procedures:ALL CLEANUP OPERATIONS SHOULD BE PERFORMED
ACCORDING TO THE STANDARD OPERATING PROCEDURES ESTABLISHED FOR YOUR
FACILITY & BY NRC/OTHER REGULATIONS.
Handling
Handling and Storage Precautions:PROTECT FROM LIGHT. STORE AT
35.6F-46.4F & DISCARD AFTER 6 HOURS FROM TIME OF PREPARATION.
HANDLING TIME SHOULD BE KEPT TO A MINIMUM.
Other Precautions:HANDLING DEVICES SUCH AS SYRINGE SHIELDS & TONGS
SHOULD BE USED. REMOVE ANY CONTAMINATION FROM SKIN, EYES/CLOTHING.
RADIOACTIVE DRUGS MUST BE HANDLED BY QUALIFIED PERSONNEL. AVOID
CONTACT W/RADIOACTIV E CONTENTS.
Exposure Controls
Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC/LATEX/RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT.
Work Hygienic Practices:NO SMOKING, EATING/DRINKING SHOULD BE ALLOWD IN
ANY AREA.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:212F
Melt/Freeze Pt:M.P/F.P Text:32F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID IN A 10 ML VIAL; ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS & REDUCING AGENTS.
Stability Condition to Avoid:LIGHT
Hazardous Decomposition Products:CO2 & CO
Disposal
Waste Disposal Methods:RADIOACTIVE WASTE MUST BE HANDLED IAW/FEDERAL,
STATE & LOCAL REGULATIONS. RADIOACTIVE MATERIAL UN2982.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.