CGWCH - OCTREOSCAN

Product Identification

Product ID:OCTREOSCAN
MSDS Date:01/01/1997
FSC:6505
NIIN:00F056011
MSDS Number: CGWCH

Responsible Party
MALLINCKRODT MEDICAL INC
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043-3421
US

Emergency Phone: 314-770-7800

Info Phone: 314-770-7800/314-895-2000

Cage: FO650

Contractor
MALLINCKRODT MEDICAL INC
MARYLAND HEIGHTS, MO 63043-3421 US

Telephone: 314-770-7800/314-895-2000

Cage: FO650

Ingredients

PENETREOTIDE

CAS: 138661-02-6

Fraction By Weight: 0.06%


INOSITOL *98-1*

CAS: 87-89-8

RTECS: NM7520800

Fraction By Weight: 57.8%


SODIUM CITRATE

CAS: 6132-04-3

Fraction By Weight: 28.4%


2,5-DIHYDROXYBENZOIC ACID

CAS: 490-79-9

RTECS: LY3850000

Fraction By Weight: 11.6%


CITRIC ACID, MONOHYDRATE

CAS: 5949-29-1

RTECS: GE7810000

Fraction By Weight: 2.1%


INDIUM CHLORIDE IN-111

CAS: 50800-85-6

Fraction By Weight: <1%


HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: <1%

OSHA PEL 5 PPM

ACGIH TLV: C 11 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


FERRIC CHLORIDE

CAS: 7705-08-0

RTECS: LJ9100000

Fraction By Weight: <1%

ACGIH TLV: 1 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >99%

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY CAUSE ASYMPTOMATIC
PHYSIOLOGICAL UPTAKE BY SPECIFIC TARGET ORGANS/TISSUES. EYES: MAY
CAUSE MECHANICAL IRRITATION. CHRONIC RADIATION EXPOSURE (CANCER,
LEUKEMIA, GENETIC & TERATOGENIC EFF ECT) INVOLVE LEVELS OF
RADIATION EXPOSURE WHICH ARE MUCH HIGHER THAN THOSE PERMITTED.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION.

First Aid

First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. ALWAYS BLOT DRY. DON'T
ABRADE. EYES: WASH W/WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN
ALL CASES.

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH APPROVED
SCBA W/FULL FACEPIECE OPERATED IN THE PRESSURE DEMAND/OTHER
POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:NON-FLAMMABLE. SOLUTION MAY EMIT
RADIOACTIVE FUMES CONTAINING IN-111.

Accidental Release

Spill Release Procedures:ALL CLEANUP OPERATIONS SHOULD BE PERFORMED
ACCORDING TO THE STANDARD OPERATING PROCEDURES ESTABLISHED FOR YOUR
FACILITY & BY NRC/OTHER REGULATIONS.

Handling

Handling and Storage Precautions:PROTECT FROM LIGHT. STORE AT
35.6F-46.4F & DISCARD AFTER 6 HOURS FROM TIME OF PREPARATION.
HANDLING TIME SHOULD BE KEPT TO A MINIMUM.
Other Precautions:HANDLING DEVICES SUCH AS SYRINGE SHIELDS & TONGS
SHOULD BE USED. REMOVE ANY CONTAMINATION FROM SKIN, EYES/CLOTHING.
RADIOACTIVE DRUGS MUST BE HANDLED BY QUALIFIED PERSONNEL. AVOID
CONTACT W/RADIOACTIV E CONTENTS.

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC/LATEX/RUBBER
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LABCOAT.
Work Hygienic Practices:NO SMOKING, EATING/DRINKING SHOULD BE ALLOWD IN
ANY AREA.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:212F
Melt/Freeze Pt:M.P/F.P Text:32F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID IN A 10 ML VIAL; ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS & REDUCING AGENTS.
Stability Condition to Avoid:LIGHT
Hazardous Decomposition Products:CO2 & CO

Disposal

Waste Disposal Methods:RADIOACTIVE WASTE MUST BE HANDLED IAW/FEDERAL,
STATE & LOCAL REGULATIONS. RADIOACTIVE MATERIAL UN2982.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.