CGZNN - 940911, TISAB III CONCENTRATE WITH CDTA (SUPDAT)

  • MSDS: CGZNN
  • Manufacturer: ORION RESEARCH INC
  • Product Name: 940911, TISAB III CONCENTRATE WITH CDTA (SUPDAT)
  • National Stock Number: 6810-00N011456
Product Identification

Product ID:940911, TISAB III CONCENTRATE WITH CDTA (SUPDAT)
MSDS Date:10/15/1996
FSC:6810
NIIN:00N011456
MSDS Number: CGZNN

Responsible Party
ORION RESEARCH INC
500 CUMMINGS CENTER
BEVERLY, MA 01915-6199
US

Emergency Phone: 508-922-4400

Info Phone: 508-922-4400

Preparer: FLYNN

Cage: 30260

Contractor
ORION RESEARCH INC
BOSTON, MA 02129 US

Telephone: 617-242-3900

Cage: 30260

Ingredients

AMMONIUM CHLORIDE (CERCLA)

CAS: 12125-02-9

RTECS: BP4550000

Fraction By Weight: 26%

OSHA PEL 10 MG/M3

ACGIH TLV: 10 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETIC ACID, AMMONIUM SALT; (AMMONIUM ACETATE) (CERCLA)

CAS: 631-61-8

RTECS: AF3675000

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CRESOL RED, SODIUM SALT, INDICATOR GRADE

CAS: 62625-29-0

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


TRANS-1,2-DIAMINOCYCLOHEXANE-N,N,N',N'-TETRAACETIC ACID

CAS: 13291-61-7

Fraction By Weight: 2%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >66%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION MAY CAUSE NAUSEA,
VOMITING, AND ACIDOSIS. SIGNS & SYMPTOMS OF EXPOSURE: COUGHING,
DYSPNEA, IRRITATION OF UPPER RESPIRATORY TRACT AND STOMACH.
CHRONIC: DIFFICULTY BREATHING WEAKNESS, G ENERALLY LOW HAZARD FOR
SKIN & INHALATION, HOWEVER, REPEATED EXPOSURES MAY CAUSE SKIN
IRRITATION AND (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: BREATHING DIFFICULTIES.
Medical Cond Aggravated by Exposure:RESPIRATORY AND STOMACH AILMENTS.

First Aid

First Aid:EYES: IRRIGATE WITH WATER AT LEAST 15 MINUTES. SKIN: WASH OFF
WITH WATER. INHALATION: FRESH AIR - ARTIFICIAL RESPIRATION IF
NEEDED. INGESTION: DILUTE WITH LARGE AMOUNTS OF WATER AND CONSULT
PHYSICIAN.

Fire Fighting

Extinguishing Media:CO*2, DRY CHEMICAL, ALCOHOL FOAM OR MIST.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:VACUUM AND SET ASIDE FOR WASTE DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP WELL SEALED TO PROTECT PROD
INTEGRITY. AMMOUNIUM ACETATE IS A CERCLA HAZARD & IS SUBJECT TO
SECTION 304 OF SARA TITLE III.
Other Precautions:NO EATING OR DRINKING WHILE WORKING W/THIS PRODUCT.

Exposure Controls

Respiratory Protection:NONE. NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST. CONTROL TO EXPOSURE LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . LAB
COAT.
Work Hygienic Practices:NO EATING OR DRINKING WHILE WORKING WITH THIS
PRODUCT.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: TOTAL IONIC STRENGTH ADJUSTMENT BUFFER. PH:
4.8-5.2 @ 25C.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:14F,-10C
Spec Gravity:1.20 (H*2O=1)
pH:SUPDAT
Solubility in Water:MISCIBLE
Appearance and Odor:ORANGE LIQUID, SLIGHT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, HYPOCHLORIC BLEACHES, NH*4, NO*5, KCLO*5.
Stability Condition to Avoid:HEAT OR FLAME.
Hazardous Decomposition Products:EMIS TOXIC FUMES WHEN HEATED TO
DECOMPOSITION.

Disposal

Waste Disposal Methods:DILUTE WITH WATER AND WASH DOWN DRAIN WITH
EXCESS WATER. OBSERVE ALL FEDERAL, STATE, AND LOCAL LAWS WHEN
DISPOSING OF THIS SOLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.