CHCDP - TECHNESCAN GLUCEPTATE
- MSDS: CHCDP
- Manufacturer: MALLINCKRODT INC
- Product Name: TECHNESCAN GLUCEPTATE
- National Stock Number: 6550-00N040067
Product Identification
Product ID:TECHNESCAN GLUCEPTATE
MSDS Date:01/01/1997
FSC:6550
NIIN:00N040067
MSDS Number: CHCDP
Responsible Party
MARYLAND HEIGHTS, MO 63043
US
Emergency Phone: 314-770-7806;800-424-9300(CHEMTREC)
Info Phone: 314-770-7800
Cage: DO440
Contractor
Telephone: 314-982-5000
Cage: DO440
Ingredients
2); (STANNOUS CHLORIDE)
CAS: 7772-99-8
RTECS: XP8700000
Fraction By Weight: 1.5%
OSHA PEL 2 MG SN/M3
ACGIH TLV: 2 MG SN/M3
GLUCEPTATE CALCIUM
CAS: 29039-00-7
Fraction By Weight: 98.5%
OSHA PEL N/K
ACGIH TLV: N/K
TECHNETIUM TC 99M PERTECHNETATE
CAS: 23288-60-0
OSHA PEL N/K
ACGIH TLV: N/K
MIN, & APPROP SHIELDING SHOULD BE USED. HNDLG
RTECS: 9999999ZZ
STOR & DISP OF PROD SHOULD BE CONTROLLED IN A MANNER
RTECS: 9999999ZZ
AUTHORIZED TO LICENSE USE OF THIS RADIONUCLIDE.
RTECS: 9999999ZZ
BY HOSPITAL/CLINIC PATIENTS, IT IS EXPECTED TO BE
RTECS: 9999999ZZ
ADVERSE ENVIRONMENTAL IMPACTS.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN AND EYE IRRITATION, BUT
DUE TO THE SMALL QUANTITIES PRESENT IN EACH CONTAINER, NO ADVERSE
HEALTH EFFECTS ARE EXPECTED TO OCCUR FROM EXPOSURE.
INHALATION/INGESTION: NOT EXPECTED TO BE A HEA LTH HAZARD. CHRONIC:
NOT EXPECTED TO BEA CHRONIC HEALTH HAZARD.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN: WASH EXPOSED AREA WITH SOAP AND WATER. GET MEDICAL
ADVICE IF IRRITATION DEVELOPS. EYES: WASH THOROUGHLY WITH RUNNING
WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ADVICE IF IRRITATION
DEVELOPS. INH ALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
OXYGEN OR ARTIFICIAL RESPIRATION) . INGESTION: CALL MD IMMEDIATELY
.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE OR EXPLOSION
HAZARD.
Accidental Release
Spill Release Procedures:COLLECT NON-RADIOACTIVE SPILLS & DISPOSE OF
MATL AS NON-HAZ WASTE. IF ANY LOSS/RELEASE OF RADIOACTIVE CONTENTS
OCCUR, NOTIFY YOUR RADIA SFTY DEPARTMENT & MFR AT (314) 770-7800.
ALL CLEAN-UP OPERATIONS SHOULD BE PERFORMED ACCORDING TO THE (SUP
DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:READ PACKAGE INSERT PRIOR TO USE!
PROMPTLY REMOVE ANY CONTAMINATION FROM SKIN, EYES/CLOTHING. AVOID
ALL UNNECESSARY EXPOSURE TO CHEMICAL SUBSTANCE.
Other Precautions:DRUG SHOULD BE STORED AT 2C-30C PRIOR TO
RECONSTITUTION W/SODIUM PERTECHNETATE TC-99M. AFTER RECONSTITUTION,
SHIELDED VIAL SHOULD BE STORED AT 2C-8C & DISCARDED AFTER 6 HRS
FROM TIME OF PREPARATION. H NDLG TIME SHOULD BE KEPT TO A (ING 4)
Exposure Controls
Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . WEAR CLEAN BODY-COVERING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILLS PROC: STD OPERATING PROC (SOPS) ESTABLISHED FOR YOUR FACILITY &
BY NRC/OTHER APPLIC LOC, STATE/FED REGS. WASTE DISP METH: WASTE
MUST BE HANDLED AS BIOHAZ & DISPOSED OF ACCORDINGLY. IF NOT RADIO
ACTIVE/BIOHAZ, WASTE IS CONSIDERED NON-HAZ. CONSULT LOC, STATE &
FED REGS FOR PROPER DISPOSAL.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Solubility in Water:SOLUBLE
Appearance and Odor:SMALL, DRY, WHITE CRYSTALS CLINGING TO INSIDE OF
10ML GLASS VIALS
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION,
SUBSTANCE MAY EMIT OXIDES OF CARBON AND CORROSIVE FUMES OF
HYDROCHLORIC ACID.
Disposal
Waste Disposal Methods:RADIOACTIVE WASTE UNTIL ACTIVITY HAS DECAYED TO
NONDETECTABLE LEVELS. RADIOACTIVE WASTE MUST BE HANDLED I/A/W PROC
ESTABLISHED BY YOUR RADIA SFTY OFFICER, NRC & OTHER APPLIC REGS. IF
MED WASTE IS INVO LVED, SUCH AS BLOOD, BLOOD PRODS/SHARPS, (SUP
DAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.