CHDMS - ETHYL ETHER, E198-4

  • MSDS: CHDMS
  • Manufacturer: FISHER SCIENTIFIC
  • Product Name: ETHYL ETHER, E198-4
  • National Stock Number: 6810-00N086071
Product Identification

Product ID:ETHYL ETHER, E198-4
MSDS Date:01/09/1995
FSC:6810
NIIN:00N086071
MSDS Number: CHDMS

Responsible Party
FISHER SCIENTIFIC
1 REAGENT LANE
FAIRLAWN, NJ 07410
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 201-796-7100

Cage: 1B464

Contractor
FISHER SCIENTIFIC CO. CHEMICAL MFG DIV
FAIRLAWN, NJ 07410-2802 US

Telephone: 201-796-7100

Cage: 1B464

Ingredients

ETHANE, 1,1'-OXYBIS-; (ETHYL ETHER) (CERCLA)

CAS: 60-29-7

RTECS: KI5775000

Fraction By Weight: >98%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM/500 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


SODIUM PEROXIDE, TRIETHYL ALUMINUM + AIR, TRIMETHYL

RTECS: 9999999ZZ


MAY CAUSE RESP FAILURE, POSSIBLY LEADING

RTECS: 9999999ZZ


PRLNGD/RPTD SKIN CNTCT MAY CAUSE DEFAT &

RTECS: 9999999ZZ


AS ANXIETY, DEPRESSION & EXCITABILITY. TARGET

RTECS: 9999999ZZ


IMMED. IF NOT BRTHG, GIVE ARTF RESP. IF

RTECS: 9999999ZZ


TREAT SYMPTOMATICALLY AND SUPPORTIVELY. NO SPECIFIC

RTECS: 9999999ZZ


IN DIRECT SUNLIGHT. STORE IN TIGHTLY CLSD

RTECS: 9999999ZZ


FROM INCOMPATIBLE SUBSTANCES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) 1215 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: CAUSES IRRIT. SKIN: MAY
CAUSE IRRIT. PRLNGD AND/OR RPTD CONT MAY CAUSE DEFAT OF SKIN &
DERM. MAY BE ABSORBED THRU SKIN. RPTD EXPOS MAY CAUSE BURNS.
INGEST: ASPIR HAZARD. SYMPS MAY INCL: HD CH, EXCITEMENT, FATG,
NAUS, VOMIT, STUPOR, & COMA. MAY CAUSE CNS DEPRESS, CHARACTERIZED
BY EXCITEMENT, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: FOLLOWED BY HDCH, DIZZ, DROW, & NAUS.
ADVANCED STAGES MAY CAUSE COLLAPSE, UNCON, COMA & POSS DEATH DUE TO
RESP FAILURE. ASPIR OF MATL INTO LUNGS MAY CAUSE CHEM PNEUM, WHICH
MAY BE FATAL. INH AL: INHAL OF HIGH CONCS MAY CAUSE CNS EFTS
CHARACT BY HDCH, DIZZ, UNCON & COMA. MAY CAUSE RESP TRACT IRRIT.
(ING 3)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/PLENTY OF WATER FOR @ LST 15 MINS, OCCASNLY
LIFTING UPPER & LOWER LIDS. GET MED AID. SKIN: FLUSH W/PLENTY OF
SOAP & WATER FOR @ LST 15 MINS WHILE REMOVING CONTAMD CLTHG &
SHOES. GET MED AID IF IRRIT DEVELOPS/PERSISTS. INGEST:DO NOT
INDUCE VOMIT. IF VICTIM IS CONSCIOUS & ALERT, GIVE 2-4 CUPFULS OF
MILK/WATER. POSS ASPIR HAZ. GET MED AID IMMED. INHAL: REMOVE TO
FRESH AIR (ING 6)

Fire Fighting

Flash Point:-49F,-45C
Lower Limits:1.85%
Upper Limits:48%
Extinguishing Media:WATER MAY BE INEFFECTIVE. USE DRY CHEMICAL, CARBON
DIOXIDE, OR ALCOHOL-RESISTANT FOAM.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . USE WATER SPRAY TO KEEP FIRE-EXPOSED CNTNRS COOL. MATL
IS LIGHTER THAN WATER & FIRE MAY (SUPDAT)
Unusual Fire/Explosion Hazard:VAPS MAY FORM AN EXPLOSIVE MIXTURE W/AIR.
VAPS CAN TRAVEL TO SOURCE OF IGNIT & FLASH BACK. EXTREMELY FLAMM.
MATERIAL WILL READILY IGNITE AT ROOM TEMPERATURE.

Accidental Release

Spill Release Procedures:AVOID RUNOFF INTO STORM SEWERS & DITCHES WHICH
LEAD TO WATERWAYS. REMOVE ALL SOURCES OF IGNIT. ABSORB SPILL USING
ABSORBENT, NON-COMBUST MATERIAL SUCH AS EARTH, SAND, OR
VERMICULITE. USE PROPER PERSON AL PROTECTIVE EQUIPMENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT GET ON SKIN & CLTHG. EMPTY
CNTNRS RETAIN PROD RESIDUE, (LIQUID AND/OR VAPOR), AND CAN BE
DANGEROUS. DO NOT GET ON SKIN OR IN EYES.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
GRIND/EXPOS SUCH CNTNRS TO HEAT, SPKS/OPEN FLAMES. DO NOT
INGEST/INHALE. IF PEROXIDE FORMATION IS SUSPECTED, DO NOT OPEN/MOVE
CNTNR. KEEP AWAY FROM SOURCES OF IGNIT. DO NOT STORE (ING 8)

Exposure Controls

Respiratory Protection:FOLLOW OSHA RESPIRATOR REGULATIONS FOUND IN
29CFR1010.134. ALWAYS USE A NIOSH-APPROVED RESPIRATOR WHEN
NECESSARY.
Ventilation:USE EXPLO-PROOF VENT EQUIP. USE ADEQ GEN/LOC EXHAUST VENT
TO KEEP AIRBORNE CONCS BELOW PERMISSIBLE EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . WEAR
APPROPRIATE PROTECTIVE CLOTHING TO PREVENT SKIN EXPOSURE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. REMOVE CONTAMD
CLOTHING & WASH BEFORE REUSE.
Supplemental Safety and Health
FIRE FIGHT PROC: BE SPREAD BY USE OF WATER. CNDTNS TO AVOID: INCOMPAT
MATLS, LIGHT, IGNIT SOURCES, EXPOS TO AIR, STRONG ACIDS, OXIDIZERS.
MATLS TO AVOID: ALUMINUM HYDRIDE, NITRATES, NITRIC ACID, NITRO SYL
PERCHLORATE, NITRYL PERCHLORATE, OZINE, PERCHLORIC ACID,
PERMANGANATES + SULFURIC ACID, POTASSIUM PEROXIDE, (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:94.1F,34.5C
Melt/Freeze Pt:M.P/F.P Text:-177F,-116C
Vapor Pres:442
Vapor Density:2.55
Spec Gravity:0.71
Evaporation Rate & Reference:37.5 (BUTYL ACETATE =1)
Solubility in Water:8.43% @ 59F
Appearance and Odor:COLORLESS LIQUID. SWEET, AROMATIC ODOR.

Stability

Stability Indicator/Materials to Avoid:NO
ACETYL PEROXIDE, AIR, BROMOAZIDE, CHLORINE, CHLORINE TRIFLUORIDE,
CHROMIC ANHYDRIDE, CHROMYL CHLORIDE, LITHIUM (SUPDAT)
Stability Condition to Avoid:NOT STABLE DURING ROUTINE USE & HNDLG
CNDTNS. PRLNGD EXPOS TO AIR & SUNLIGHT MAY FORM UNSTABLE PEROXIDES.
(SUPDAT)
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
PEROXIDES.

Disposal

Waste Disposal Methods:DISPOSE OF IN MANNER CONSISTENT WITH FEDERAL,
STATE, AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.