CHJYJ - SEALED MAINTENANCE FREE LEAD ACID BATTERIES
- MSDS: CHJYJ
- Manufacturer: KUNG LONG BATTERIES INDUSTRIAL CO LTD
- Product Name: SEALED MAINTENANCE FREE LEAD ACID BATTERIES
- National Stock Number: 6140-00N087645
Product Identification
Product ID:SEALED MAINTENANCE FREE LEAD ACID BATTERIES
MSDS Date:10/01/1994
FSC:6140
NIIN:00N087645
MSDS Number: CHJYJ
Responsible Party
US
Emergency Phone: 886-581-0413
Info Phone: 886-581-0413
Cage: JO437
Contractor
Telephone: 886-2-5810413
Cage: KUMGL
Ingredients
621F (327.4C); SPEC GRAV
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 70%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.15 MG/M3 DUST
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
NONE; LD50
RTECS: 9999999ZZ
1958F (1070C); SPEC
CAS: 15739-80-7
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.15 MG(PB)/M3
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
NONE
RTECS: 9999999ZZ
9.4; SOL IN
CAS: 1309-60-0
RTECS: OG0700000
OSHA PEL N/K
ACGIH TLV: N/K
237F (114C); SPEC GRAV
CAS: 8014-95-7
RTECS: WS5605000
Fraction By Weight: 20%
OSHA PEL N/K
ACGIH TLV: 1 MG/M3/3 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
NONE;
RTECS: 9999999ZZ
SLIGHT; APPEAR/ODOR
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: N/K
SOLID
Fraction By Weight: 6%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: LEAD: TOX EFTS ARE ACCUMULATIVE
& SLOW TO APPEAR. IT AFFECTS KIDNEYS, REPRO SYS, & CNS. SYMPS OF
LEAD OVEREXP ARE ANEMIA, VOMIT, HDCH, STOM PAIN (LEAD COLIC), DIZZ,
LOSS OF APPETITE, & MUSCLE & JOINT PAIN. EXPOS TO LEAD FROM
BATTERYMOST OFTEN OCCURS DURING LEAD RECLAIM OPERATIONS THRU BRTHG
OR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:SULFURIC ACID: IARC MONOGRAPHS, VOLUME
54, PAGE 41, 1992: GROUP 1. ANIMAL: PULMONARY IRRITATION.
Effects of Overexposure:HLTH HAZ: INGEST OF LEAD DUSTS & FUMES.
SULFURIC ACID: STRONG CORR. CONT W/ACID CAN CAUSE SEV BURNS OF SKIN
& EYES. INGEST WILL CAUSE GI TRACT BURNS. ACID CAN BE RELEASED IF
BATTERY CASE IS DAMAGED/IF VENTS ARE TEMPERED WITH. FIBERGLASS
SEPARATOR: FIBROUS GLASS IS AN IRRITANT OF UPPER RESP TRACT, SKIN &
EYES. (SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN: FLUSH W/WATER. SEE MD IF CONT AREA IS LARGE/BLISTERS
FORM. EYES: CALL MD IMMED & FLUSH W/WATER FOR AT LEAST 15 MINUTES,
UNTIL MD ARRIVES. INGEST: CALL MD. IF PATIENT IS CONSCIOUS, FLUSH
MOUTH W/ WATER. HAVE PATIENT DRINK MILK/SODIUM BICARBONATE
SOLUTION. DO NOT GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. INHAL:
REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL
RESPIRATION) .
Fire Fighting
Flash Point:NONE
Lower Limits:SEE INGS
Upper Limits:SEE INGS
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:SEALED BATTERIES CAN EMIT HYDROGEN ONLY
IF OVERCHARGED (FLOAT VOLTAGE >2.40 VPC). TOX VAPS MAY BE RELEASED
IN CASE OF FIRE. TEMPS >300C (572F) MAY (SUP DAT)
Accidental Release
Spill Release Procedures:IF SULFURIC ACID IS SPILLED FROM BATTERY,
NEUTRALIZE ACID W/SODIUM BICARBONATE (BAKING SODA), SODIUM CARBON
(SODA ASH)/CALCIUM OXIDE (LIME). FLUSH AREA W/WATER & DISCARD TO
SEWAGE SYSTEM. DO NOT ALLOW UNNEUTRALIZED ACID INTO SEWAGE SYSTEM.
Neutralizing Agent:SODIUM BICARBONATE (BAKING SODA), SODIUM CARBON
(SODA ASH)/CALCIUM OXIDE (LIME).
Handling
Handling and Storage Precautions:PROHIBIT SMOKING, SPARKS, ETC, FROM
BATTERY CHARGING AREA. AVOID MIXING ACID WITH OTHER CHEMICALS.
Other Precautions:DUE TO BATTERY'S LOW INTERNAL RESISTANCE & HIGH POWER
DENSITY, HIGH LEVELS OF SHORT CIRCUIT CURRENT CAN BE DEVELOPED
ACROSS BATTERY TERMINALS. DO NOT SET TOOLS/CABLES ON BATTERY. USE
INSULATED TOOLS O NLY. FOLLOW ALL INSTALLATION (SUP DAT)
Exposure Controls
Respiratory Protection:A NIOSH APPROVED RESPIRATOR SHOULD BE WORN
DURING RECLAIM OPERATIONS IF THE TLV IS EXCEEDED.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA . APRON.
Work Hygienic Practices:PROTECTIVE EQUIPMENT MUST BE WORN IF THE
BATTERY IS CRACKED OR OTHERWISE DAMAGED.
Supplemental Safety and Health
EXPLO HAZ: RELEASE COMBUST GASES. EFTS OF OVEREXP: LEAD APPEARS ON THE
NAVY OCCUP CHEM REPRO HAZ LIST. CONSULT APPROP HLTH PROFESSIONALS
CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS INFO (FP N ).
OTHER PREC: INSTRUCTIONS & DIAGRAMS WHEN INSTALLING/MAINTAINING
BATTERY SYSTEMS.
Chemical Properties
Boiling Pt:B.P. Text:SEE INGS
Vapor Density:SEE INGS
Solubility in Water:SEE INGS
Appearance and Odor:SEE INGS
Stability
Stability Indicator/Materials to Avoid:YES
FOR SULFURIC ACID: REACTIVE METALS, STRONG BASES, MOST ORGANIC
COMPOUNDS.
Stability Condition to Avoid:FOR SULFURIC ACID: STABLE AT ALL
TEMPERATURES.
Hazardous Decomposition Products:SULFURIC DIOXIDE, TRIOXIDE, HYDROGEN
SULFIDE, HYDROGEN.
Disposal
Waste Disposal Methods:NEUTRALIZED ACID MAY BE FLUSHED DOWN SEWER.
SPENT BATTERIES MUST BE TREATED AS HAZARDOUS WASTE & DISPOSED OF
ACCORDING TO LOCAL, STATE, & FEDERAL REGULATIONS. A COPY OF THIS
MSDS MUST BE SUPPLIED TO A NY SCRAP DEALER/SECONDARY LEAD SMELTER
W/BATTERY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.