CHNXF - LENIUM CP
- MSDS: CHNXF
- Manufacturer: PETROFERM INC
- Product Name: LENIUM CP
- National Stock Number: 6850-00N088108
Product Identification
Product ID:LENIUM CP
MSDS Date:10/08/1997
FSC:6850
NIIN:00N088108
MSDS Number: CHNXF
Responsible Party
FERNANDINA BEACH, FL 32034
US
Emergency Phone: 703-527-3887;800-424-9300(CHEMTREC)
Info Phone: 904-261-8286
Cage: 0WUA8
Contractor
Telephone: 904-261-8286
Cage: 0WUA8
Ingredients
(ORAL, RAT) 4,260 MG/KG.
CAS: 106-94-5
RTECS: TX4110000
Fraction By Weight: 10-30%
OSHA PEL N/K
ACGIH TLV: N/K
(ORAL, RAT) >5,000
CAS: 163702-07-6
RTECS: 9999999ZZ
Fraction By Weight: 60-80%
OSHA PEL N/K
ACGIH TLV: N/K
(ORAL, RAT) >5,000
CAS: 163702-08-7
RTECS: 9999999ZZ
Fraction By Weight: 60-80%
OSHA PEL N/K
ACGIH TLV: N/K
(ORAL, RAT) 5,500 MG/KG.
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 3-8%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM; 500 STEL
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY IRRITATE THE NOSE,
THROAT AND LUNGS. EXPOSURE TO HIGH DOSES MAY CAUSE CENTRAL NERVOUS
SYSTEM DEPRESSION (ANESTHETIC-LIKE EFFECTS). DOSES WHICH CAUSE
ANESTHETIC-LIKE EFFECTS ALSO CAUSE ADVERSE EFFECTS IN LIVER, LUNG
AND KIDNEY. INGESTION: LOW ORDER OF TOXICITY. MAY CAUSE MILD
NAUSEA, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: AND ABDOMINAL DISCOMFORT. SKIN:
PROLONGED EXPOSURE WILL CAUSE A SKIN IRRITATION. EYES: CONTACT WITH
EYES MAY CAUSE MILD IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CONSULT MD.
INGEST: DO NOT INDUCE VOMITING. SEEK MEDICAL ATTENTION. SKIN:
REMOVE CONTA MINATED CLOTHING. THOROUGHLY WASH AFFECTED AREA W/SOAP
& WATER; USE SKIN CREAM IF IRRITATION IS SEVERE. EYES: IMMEDIATELY
FLUSH EYES WITH WATER FOR AT LEAST 15 MINUTES. CALL MD IF
IRRITATION PERSISTS.
Fire Fighting
Flash Point Method:PMCC
Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CHEMICAL FOAM, CARBON DIOXIDE. CLASS
BC, ABC FIRE EXTINGUISHER.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP
(BUNKER COAT & PANTS, BANDS AROUND ARMS, WAIST & LEGS, FACE MASK &
PROT COVERING FOR EXPOS AREAS OF HEAD).
Unusual Fire/Explosion Hazard:VAPORS CAN TRAVEL CONSIDERABLE DISTANCES
TO SOURCE OF IGNITION. EXPOSURE TO EXTREME HEAT CAN GIVE RISE TO
THERMAL DECOMPOSITION.
Accidental Release
Spill Release Procedures:ABSORB SPILL WITH INERT MATERIAL, THEN PLACE
IN CHEMICAL WASTE CONTAINER. CLEAN UP RESIDUE WITH AN APPROPRIATE
ORGANIC SOLVENT. FOR LARGE SPILLS, DIKE FOR LATER DISPOSAL. OBSERVE
GOVERNMENT REGULATION S.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN ORIGINAL CONTAINER,
PREFERABLY IN A COOL VENTILATED, FIRE-RESISTANT BUILDING. AVOID
OVERHEATING OR FREEZING. AVOID OPEN FLAMES AND SPARKS.
Other Precautions:SINCE EMPTY CONTAINERS MAY RETAIN PRODUCT RESIDUES
(VAPOR, LIQUID OR SOLID) ALL LABEL PRECAUTIONS MUST BE OBSERVED.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR IF VENTILATION IS
NOT SUFFICIENT AND IF MISTS ARE GENERATED.
Ventilation:IF DESIRABLE TO REDUCE ODOR, LOCAL EXHAUST CAN ALSO BE
EFFECTIVE IN MINIMIZING ODOR. PROVIDE SUFFICIENT VENT (SUPDAT)
Protective Gloves:CHEMICALLY RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT: TO MAINTAIN EMISSIONS BELOW RECOMMENDED EXPOSURE LIMITS.
Chemical Properties
Boiling Pt:B.P. Text:130F,54C
Vapor Pres:150 @ 20C
Vapor Density:>1
Spec Gravity:1.43 (H*2O=1)
Evaporation Rate & Reference:<1 (BUAC=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH A SLIGHT ETHEREAL
ODOR.
Percent Volatiles by Volume:100 WT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG MINERAL ACIDS & STRONG OXIDIZING AGENTS. PRLNGD CNTCT
W/ALUMINUM, MAGNESIUM & ZINC METALS SHOULD BE AVOIDED.
Stability Condition to Avoid:TEMPERATURES ABOVE 130F.
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS ARE
KNOWN TO BE HAZARDOUS.
Disposal
Waste Disposal Methods:WASTE TREAT OR INCINERATE USED MATERIAL IN
COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL GOVERNMENT
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.