CHPBX - KENITE K300
- MSDS: CHPBX
- Manufacturer: CELITE CORP
- Product Name: KENITE K300
- National Stock Number: 9390-00N088405
Product Identification
Product ID:KENITE K300
MSDS Date:05/03/1997
FSC:9390
NIIN:00N088405
MSDS Number: CHPBX
Responsible Party
US
Emergency Phone: 703-527-3887;800-424-9300(CHEMTREC)
Info Phone: 805-735-7791
Preparer: CHRIS PAULEY
Cage: 9K562
Contractor
Telephone: 805-735-7791
Cage: CELXT
Ingredients
DIATOMACEOUS EARTH, FLUX-CALCINED
CAS: 68855-54-9
Fraction By Weight: 100%
OSHA PEL N/K
ACGIH TLV: N/K
SILICA, CRYSTALLINE - CRISTOBALITE
CAS: 14464-46-1
RTECS: VV7325000
Fraction By Weight: <93%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.05 MG/M3 RDUST
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: <1%
OSHA PEL SEE TABLE Z-3
ACGIH TLV: 0.1 MG/M3 RDUST
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: TRANSITORY UPPER RESPIRATORY OR
EYE IRRITATION. INHALATION: IRRITATION AND SORENESS IN THROAT &
NOSE. IN EXTREME EXPOSURES SOME CONGESTION MAY OCCUR. EYES:
TEMPORARY IRRITATION OR INFLAMMATION. CHRONIC: INHALATION OF
CRYSTALLINE SILICA HAS BEEN CLASSIFIED BY IARC AS CARCINOGENIC FOR
HUMANS (EFFECTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-CRISTOBALITE &
SILICA, CRYSTALLINE-QUARTZ: IARC MONOGRAPHS, VOL 68, 1997: GROUP 1.
NTP 7TH (SUPDAT)
Effects of Overexposure:HLTH HAZ: (GROUP 1). INHALATION OF CRYSTALLINE
SILICA IS ALSO KNOWN CAUSE OF SILICOSIS A NONCANCEROUS LUNG DISEASE
CAUSED BY EXCESSIVE EXPOSURE TO CRYSTALLINE SILICA. TARGET ORGANS:
LUNGS, EYES.
Medical Cond Aggravated by Exposure:PRE-EXISTING UPPER RESPIRATORY AND
LUNG DISEASE SUCH AS, BUT NOT LIMITED TO BRONCHITIS. EMPHYSEMA AND
ASTHMA.
First Aid
First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:FLUSH W/COPIOUS AMOUNTS OF
WATER. CALL MD . INHALATION: REMOVE TO FRESH AIR. DRINK WATER TO
CLEAR THROAT AND BLOW NOSE TO EVACUATE DUST. EYES: FLUSH WITH
LARGE QUANTITIES OF WATER FOR AT LEAST 15 MINUTES. IF IRRITATION
PERSISTS CONSULT A PHYSICIAN.
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:NOT APPLICABLE. MEDIA SUITABLE FOR SURROUNDING FIRE
.
Fire Fighting Procedures:NONE. USE NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:VACUUM CLEAN DUST WITH EQUIPMENT FITTED WITH
HEPA FILTER. USE A DUST SUPPRESSANT SUCH AS WATER IF SWEEPING IS
NECESSARY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:MINIMIZE DUST GENERATION AND
ACCUMULATION. AVOID BREATHING DUST. AVOID CONTACT WITH EYES.
Other Precautions:SEAL BROKEN BAGS IMMEDIATELY. CONTINUE TO FOLLOW ALL
MSDS/LABEL WARNINGS WHEN HANDLING EMPTY CONTAINERS.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATORS: <10 X PEL USE 3M
9900: <100 X PEL, USE MSA ULTRA TWIN WITH H FILTER; <200 PEL USE
MSA 01-00-06 WITH TYPE C SUPPLIED AIR UNIT (CONT. FLOW MODE); OR
EQUIVALENT.
Ventilation:USE SUFFICIENT NATURAL OR MECHANICAL VENTILATION TO KEEP
DUST LEVEL BELOW PEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN: ANNUAL REPORT ON CARCINOGENS, 1994: ANTICIPATED TO BE
CARCINOGEN. WASTE DISP METH: BASED ON CONTAMINANTS AND SHOULD BE
EVALUATED ACCORDINGLY.
Chemical Properties
Spec Gravity:2.3 (WATER =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:FINE WHITE POWDER, NO ODOR.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID.
Stability Condition to Avoid:NONE IN DESIGNED USE.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:WASTE IS NOT HAZ AS DEFINED BY RCRA(40 CFR 261).
METHOD OF DISP IS TO LANDFILL. OTHER FEDERAL, STATE AND LOCAL
REGULATIONS MAY VARY. CONSULT LOCAL AGENCIES AS NEEDED. USED MATL
WHICH HAS BECOME CONTAM D MAY HAVE SIGNIFICANT DIFFERENT CHARACT
(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.